Skip to content

NovaSolver Studio 0.7.5

Choose a tag to compare

@novasolver-dev novasolver-dev released this 03 Nov 23:05
· 100 commits to main since this release

NovaSolver Studio 0.7.5

  • Fixed: in the downloaded app, the built-in solver failed on models above about 30,000 unknowns (for example a fine mesh) with PackageNotFoundError. Each release build now solves such models before it ships.
  • Build an instant-answer model of your own case: tell your AI tool which numbers to vary and over what ranges (build_surrogate). Studio solves the variants in the background, checks the fit on solves it kept back, and then answers in milliseconds with an error bar (surrogate_predict). It refuses outside the ranges, and it reports the mesh error of the solves it learned from. Template dimensions, loads and materials can vary; an imported CAD shape cannot yet.
  • NovaSolver Flash is now a Gaussian process learned from the solved points. On 224 new shapes it had never seen, 287 of 288 answers fell inside its error bar. The L-bracket deflection bar, which used to hold only 24 of 32, now holds 31 of 32. Try it in your browser: https://novasolver.jp/en/studio/

NovaSolver Studio 0.7.5

  • 配布版の内蔵ソルバーで、未知数が約 3 万を超えるモデル(細かいメッシュなど)が PackageNotFoundError で失敗する不具合を直しました。今後はリリースごとに、配布版でこの規模のモデルを解いて確かめます。
  • 自分の解析から即答モデルを作れるようになりました。AI ツールに、変える数値と範囲を伝えるだけです(build_surrogate)。Studio が裏で解いて、取り置いた解析結果で当てはまりを確かめ、その後はミリ秒で誤差幅つきの答えを返します(surrogate_predict)。範囲の外では答えません。学習に使ったメッシュの誤差も報告します。変えられるのはテンプレートの寸法、荷重、材料です。読み込んだ CAD 形状の寸法はまだ変えられません。
  • NovaSolver Flash を、解析点から学習するガウス過程に切り替えました。モデルが一度も見ていない新しい 224 形状で、288 件のうち 287 件が誤差幅に収まりました。32 件中 24 件しか収まらなかった L 字ブラケットのたわみは、32 件中 31 件になりました。ブラウザで試せます:https://novasolver.jp/studio/

NovaSolver Studio 0.7.5

  • 修复问题:在下载版中,内置求解器处理未知数超过约 3 万的模型(例如细网格)时会因 PackageNotFoundError 失败。今后每次发布前都会用下载版实际求解这种规模的模型。
  • 现在可以用自己的算例构建即时回答模型:只需告诉 AI 工具要改变哪些数值及其范围(build_surrogate)。Studio 在后台求解,用预留的求解结果检查拟合,之后在几毫秒内给出带误差范围的答案(surrogate_predict)。超出范围时不给出答案,并会报告训练所用网格的误差。可改变模板尺寸、载荷和材料;导入的 CAD 形状尺寸暂不能改变。
  • NovaSolver Flash 改为从已求解的点学习的高斯过程。在模型从未见过的 224 种新形状上,288 个答案中有 287 个落在误差范围内。L 形支架挠度原来 32 个中只有 24 个落在范围内,现在为 32 个中 31 个。可在浏览器中试用:https://novasolver.jp/zh/studio/

Download

  • NovaSolverStudio-0.7.5-win64-setup.exe (Windows 10/11 installer, per user, no administrator rights; Start menu, .nscase double-click)
    SHA-256: 923273ef0899866316dbbb250f843cad5b26b8b814f18332201ffc19b8eae786
  • NovaSolverStudio-0.7.5-win64.zip (Windows 10/11, portable: unzip and double-click NovaSolverStudio.exe)
    SHA-256: 6359e3ed525cd4be6865ed92760bb94d4d42237c08cfe0b9ed4fa1ad3c58bf2f
  • novasolver-studio-0.7.5-win64.mcpb (one-click install for Claude Desktop and other MCP clients)
    SHA-256: 58f376b0fb51213a75507075360d5b1bdf0e5a3def25263b9961a235fd1402f7
  • novasolver_studio-0.7.5-py3-none-any.whl (macOS / Linux / Windows with Python 3.10+:
    uvx --from <this file's URL> novasolver-studio)
    SHA-256: 756dd9b845490361f38cc072b8003726fa7ffaa9b6a591601dc4e375437399b2

The installer and the zip are built on GitHub Actions from this tag (public build log). They are not code-signed
yet: if Windows SmartScreen warns, choose More info → Run anyway.
Flow analyses need OpenFOAM® (guide: https://novasolver.jp/en/studio/).

License: GPL-3.0. Called programs keep their own licenses (see THIRD_PARTY_NOTICES.md).
This offering is not approved or endorsed by OpenCFD Limited, producer and distributor of the OpenFOAM software via www.openfoam.com, and owner of the OPENFOAM® and OpenCFD® trade marks.


Solved examples, NovaSolver Studio 0.7.5

Each file is a verification case solved by Studio's built-in solver, with its result. Open it with
Open case file in Studio, or from an AI assistant with open_example. Studio downloads these by itself from the
Start screen ("Solved examples"); you only need them by hand when offline. 27 examples, 57.7 MB.

Case Reference Studio Error Size
Cantilever beam 0.9831 mm 0.9755 mm -0.77% 0.5 MB
Lid-driven cavity -0.2109 m/s -0.2115 m/s +0.12% 0.1 MB
Heat conduction block 40 W 40 W -0.00% 0.3 MB
Plate with a hole in tension 2.512 - 2.531 - +0.75% 3.0 MB
Cooling fin 5.066 W 5.064 W -0.05% 0.3 MB
Parallel-plate capacitor 23.24 pF 23.24 pF -0.00% 14.9 MB
Coaxial cable 0.9326 pF 0.9328 pF +0.03% 1.3 MB
Busbar Joule heating 7.641 K 7.641 K -0.00% 5.1 MB
Cantilever natural frequencies 206.4 Hz 206.5 Hz +0.06% 2.5 MB
Column buckling (fixed-free) 2634 N 2639 N +0.18% 1.0 MB
Column buckling (both ends clamped) 4.215e+04 N 4.201e+04 N -0.33% 1.0 MB
Fatigue of a bar (Goodman) 1.778 - 1.778 - -0.00% 0.5 MB
Restrained heated bar 246 MPa 246 MPa +0.00% 0.5 MB
Free thermal expansion 0.12 mm 0.12 mm +0.00% 0.5 MB
Hanging bar under gravity 0.0001878 mm 0.0001878 mm -0.00% 2.6 MB
Rotating disk 35.51 MPa 35.58 MPa +0.20% 0.2 MB
Shaft torsion 0.01615 rad 0.01615 rad +0.00% 9.0 MB
Large cantilever 60.34 mm 60.22 mm -0.20% 3.3 MB
Plastic bar 268 MPa 268 MPa -0.00% 0.7 MB
Plastic beam collapse 1250 N 1280 N +2.44% 6.9 MB
Rubber tension 29.54 MPa 29.54 MPa +0.00% 0.2 MB
Press fit 76.88 MPa 76.96 MPa +0.11% 0.8 MB
Stacked blocks 4000 N 4000 N -0.00% 0.2 MB
Friction block 400 N 400 N -0.00% 0.2 MB
Two blocks with a gap (contact) 1.025e+05 N 1.025e+05 N -0.00% 0.3 MB
Tying separately meshed parts 1.025e+05 N 1.025e+05 N -0.00% 0.3 MB
Cylinder on a flat (Hertz contact) 1408 MPa 1407 MPa -0.04% 1.7 MB

解析済みの例

Studio 内蔵ソルバーで解いた検証ケースを、結果ごと収めたファイルです。Studio の「ケースファイルを開く」か、AI アシスタントの
open_example で開けます。通常はスタート画面の「解析済みの例」から自動でダウンロードされます。

ケース 理論値 Studio 誤差
片持ち梁 0.9831 mm 0.9755 mm -0.77%
キャビティ流れ -0.2109 m/s -0.2115 m/s +0.12%
熱伝導ブロック 40 W 40 W -0.00%
穴あき板の引張 2.512 - 2.531 - +0.75%
冷却フィン 5.066 W 5.064 W -0.05%
平行平板コンデンサ 23.24 pF 23.24 pF -0.00%
同軸ケーブル 0.9326 pF 0.9328 pF +0.03%
母線のジュール発熱 7.641 K 7.641 K -0.00%
片持ちはりの固有振動 206.4 Hz 206.5 Hz +0.06%
柱の座屈(一端固定・他端自由) 2634 N 2639 N +0.18%
柱の座屈(両端固定) 4.215e+04 N 4.201e+04 N -0.33%
棒の疲労(グッドマン) 1.778 - 1.778 - -0.00%
両端拘束棒の熱応力 246 MPa 246 MPa +0.00%
棒の自由熱膨張 0.12 mm 0.12 mm +0.00%
自重で伸びる棒 0.0001878 mm 0.0001878 mm -0.00%
回転円板 35.51 MPa 35.58 MPa +0.20%
丸棒のねじり 0.01615 rad 0.01615 rad +0.00%
大変形片持ちはり 60.34 mm 60.22 mm -0.20%
弾塑性棒 268 MPa 268 MPa -0.00%
はりの塑性崩壊 1250 N 1280 N +2.44%
ゴムの引張り 29.54 MPa 29.54 MPa +0.00%
圧入 76.88 MPa 76.96 MPa +0.11%
積層ブロック 4000 N 4000 N -0.00%
摩擦ブロック 400 N 400 N -0.00%
すき間のある2つのブロック(接触) 1.025e+05 N 1.025e+05 N -0.00%
別々にメッシュした部品の固着 1.025e+05 N 1.025e+05 N -0.00%
円柱と平面の接触(ヘルツ) 1408 MPa 1407 MPa -0.04%