Skip to content

v4.4.1 - multi-item writes and large reads fixed

Latest

Choose a tag to compare

@oriolrius oriolrius released this 22 Oct 10:54
· 2 commits to main since this release

Fixes

  • Multi-item writes (S7 Out with arrays in msg.variable / msg.payload) failed with PLC error 0x8104 on every install that got @st-one-io/nodes7 1.1.2 (what the old ^1.1.0 range resolved to since December 2025), because it no longer sent the S7comm fill bytes (st-one-io/nodes7#16).
  • Writing many booleans/bytes at once no longer exceeds the PDU (st-one-io/nodes7#8), and reading many odd-length variables no longer fails with 0x8500 (st-one-io/nodes7#17).

Dependency

Tests

  • The E2E PLC simulator now behaves like a real CPU: it applies every item of a multi-item write, requires the fill bytes and enforces the PDU size. S7 Out single and multi-item writes are tested on Node-RED 3, 4 and 5; the multi-item case fails with @st-one-io/nodes7 1.1.2 and passes with this release. (2861b12)

Full Changelog: v4.4.0...v4.4.1