Fixes
- Multi-item writes (S7 Out with arrays in
msg.variable/msg.payload) failed with PLC error0x8104on every install that got@st-one-io/nodes71.1.2 (what the old^1.1.0range resolved to since December 2025), because it no longer sent the S7comm fill bytes (st-one-io/nodes7#16). - Writing many booleans/bytes at once no longer exceeds the PDU (st-one-io/nodes7#8), and reading many odd-length variables no longer fails with
0x8500(st-one-io/nodes7#17).
Dependency
- Uses
@oriolrius/nodes71.1.3, a fork of@st-one-io/nodes71.1.2 with these fixes (same API). The fixes are proposed upstream in st-one-io/nodes7#19. (e95ed17)
Tests
- The E2E PLC simulator now behaves like a real CPU: it applies every item of a multi-item write, requires the fill bytes and enforces the PDU size. S7 Out single and multi-item writes are tested on Node-RED 3, 4 and 5; the multi-item case fails with
@st-one-io/nodes71.1.2 and passes with this release. (2861b12)
Full Changelog: v4.4.0...v4.4.1