Date: 2026-10-29
Previous release: none (first release)
First release: CANopen reference implementations in containers behind one
contract, for interoperability testing of CANopen software such as
go-canopen.
- Container contract 1.0 (docs/CONTAINER_CONTRACT.md)
and JSON Schemas:device,sdo-upload,sdo-download(expedited,
segmented,--block),nmt,listen(boot-up, heartbeat state changes,
EMCY),pdo-configure,pdo-receive,sync,eds-check,cia402;
JSON Lines output, exit codes 0–5 with SDO abort codes. - Images
ghcr.io/otfabric/canopen-interop-<adapter>for linux/amd64 and
linux/arm64:canopennode: CANopenNode v4.1 with CANopenLinuxcanopend; the device's
object dictionary is generated from the shared EDS by CANopenEditor
v4.2.3; the master uses canopend's CiA 309-3 ASCII gateway.lely: Lely CANopen lely-core v2.3.5 through a C++ helper on
liblely-coapp (BasicSlave, AsyncMaster, Sdo) and liblely-co; Lely's
dcf-tools foreds-check.pythoncanopen: python canopen 2.4.1 on python-can 4.6.1 (LocalNode,
RemoteNode, SYNC producer, BaseNode402, EDS importer).
- Fixtures: the shared test device
fixtures/eds/interop-device.eds
(CiA 301 communication objects, four RPDOs/TPDOs, test objects 0x2000–0x200A
of every basic type, string, DOMAIN, read-only, write-only, range-limited)
and EDS/DCF fixtures for CompactSubObj, ObjectLinks, DCF ParameterValue and
an invalid file. - Self-test on vcan, every master × every device: object dictionary,
SDO (incl. block transfer and aborts) with the device's own view of the
written values, NMT and heartbeat, EMCY, event-driven, configured and
SYNC-driven TPDOs, EDS checkers. Stack differences found and documented in
tests/known-differences.tsv, among them:
lely's SDO server rejects a DOMAIN download without size indication (as
CANopenNode's gateway sends long data), CANopenNode's SDO server cannot
upload 0 bytes, python canopen's LocalNode ignores the sub-index of a VAR,
and the checkers disagree on CompactSubObj and ObjectLinks. - Not in v0.1.0 (LIMITATIONS.md): lely
syncand
pdo-configure, canopennode PDO/SYNC/EDS operations, a CiA 402 drive to
verifycia402against, RPDO senders.
Images
| Image | Digest |
|---|---|
ghcr.io/otfabric/canopen-interop-canopennode:v0.1.0 |
sha256:be2e965a11d9dbca0afd1344b1fec00efef396ac6e3eaf994a4b01555d7d0218 |
ghcr.io/otfabric/canopen-interop-lely:v0.1.0 |
sha256:9788a6c54bed94969371d73233e3b24a826874020a7b2e8698a47f3ad89a9e84 |
ghcr.io/otfabric/canopen-interop-pythoncanopen:v0.1.0 |
sha256:9e8309b16334396318dc0789dda2ee068a57e28130e0ba3c220f46cde1f180f4 |