Repository navigation
Releases: otfabric/canopenctl
Release list
v0.3.2
Date: 2026-10-31
Previous release: v0.3.1
Changed
- Policy 1.2: build output in
bin/andrelease/, a per-package coverage floor, and more tests and CI. No change in behaviour. - Built on go-canbus v0.7.2, go-canopen v0.3.3, go-serial v0.2.1.
v0.3.1
Date: 2026-10-31
Previous release: v0.3.0
Dependencies
- go-canopen v0.3.2: program download, scan and LSS node-ID assignment fixes (see its release notes), and go-canbus v0.7.1. No command changes.
v0.3.0
Date: 2026-10-30
Previous release: v0.2.1
Exit codes converge on the organisation table (ADR-0006). Scripts that test for these codes must change.
| Case | Old | New |
|---|---|---|
Missing privilege (permission) |
7 | 9 |
Interrupted before a result (code canceled) |
10 (internal) |
130 (interrupted) |
All other codes are unchanged, 11 (abort) and 12 (device) included. error-v1.schema.json adds the kind interrupted. Exit 7 is now reserved for a partial result, which canopenctl does not produce today.
CANOPENCTL_OUTPUT_FORMAT is now accepted besides CANOPENCTL_FORMAT, which is the canonical name and wins when both are set.
v0.2.1
Date: 2026-10-30
Previous release: v0.2.0
Built on go-canopen v0.3.1 (was v0.3.0).
boot: go-canopen v0.3.1 fixes a race of the network boot-up. A
slave whose boot-up arrived before the manager's NMT reset communication
was already being configured when the reset undid its configuration, and
bootreported it failed (status K); the boot-up now cancels the running
boot slave processes before the reset.- Interop scenarios for the v0.2.0 commands against canopen-interop
v0.2.0 (contract 1.1, images pinned by digest):lssagainst CANopenNode's and Lely's LSS slaves: identify, select,
inquire, bit timing, configure node-ID, store, Fastscan of unconfigured
and configured devices, assign-all; and the LSS masters of all three
stacks againstsimulate --lss(inquire, configure node-ID, store kept
across a restart with--store, Fastscan, assign-all).mpdo configure,dispatcher,scanneron Lely devices, checked
with Lely's DAM- and SAM-MPDOs and by SDO;mpdo watchof Lely's MPDOs.bootof every stack's device (concise DCF, identity, start), with the
other product's identity (error status M, exit 1), with--lssfor the
stacks' LSS slaves, and of a network with a device of every stack;
Lely's boot master bootingsimulate.cdcf convertbyte for byte against Lely's dcfgen and dictionary dump;
cdcf applyto every stack's device, read back.store/restore,programand--fd: recorded skips — no device of
the contract has 0x1010/0x1011 or 0x1F50/0x1F51 (probed: abort
0x06020000), no stack implements CANopen FD.
- Four new known differences, observed on the bus: CANopenNode v4.1's LSS
slave answers neither identify service; Lely's LSS slave applies a
configured node-ID only at NMT reset communication and answers Fastscan
also when configured. LIMITATIONS.md says how to work with them.
Verification:
- Interop on Linux 7.0 arm64 (vcan0), full suite twice with identical
results, the new scenarios three more times: 152 pass, 5 known
differences, 63 skips, 0 failures (before: 93 pass, 1 known, 17 skips).
Per adapter: canopennode 48/2/23, lely 62/3/8, pythoncanopen 41/0/32,
mixed network 1 pass. make check(fmt, staticcheck, golangci-lint, vet, cross, govulncheck,
tests with the race detector, coverage 93.0 %); golangci-lint and go vet
with the interop build tag.
v0.2.0
Date: 2026-10-29
Previous release: v0.1.1
Built on go-canopen v0.3.0 (was v0.2.0): LSS, MPDO, CiA 302 network
management and CANopen FD.
lss: an LSS master (CiA 305).switch(global),select
(selective, by LSS address),inquire(address and node-ID),
configure(node-ID, bit rate from the CiA 301 table, store),activate
(bit timing switch),identify(non-configured devices, or an address
range),fastscan(the addresses of every unconfigured device) and
assign-all(a node-ID for each, with--avoidand--store). A
refusal is exit 12 (lss_refused), no answer exit 5 (no_response).mpdo:configuremakes a TPDO or RPDO an MPDO in source or
destination address mode,scanneranddispatcherwrite the object
scanner and dispatcher lists,watchdecodes MPDOs (passive).boot: the CiA 302-2 network boot-up as a manager — slaves with their
DCF or concise DCF, expected identities, mandatory and optional slaves,
--lssfor the LSS step that gives unconfigured devices the node-ID of
the slave whose identity they have,--store,--no-start. The result
lists each slave's CiA 302 boot status; a failed slave is exit 1.cdcf convert,show,apply: concise DCFs (0x1F22) from DCFs
(PDOs in the CiA 301 sequence), listed, and written entry by entry.storeandrestore(0x1010/0x1011,--group,restore --reset);program download(CiA 302-3: stop, clear, image, flash
status, identification, start),program controlandprogram status.- CANopen FD:
--fd(and--brs) onsdo read/write/dump(USDO
client,--blockfor bulk downloads,--client-id),scan,nmt,
heartbeat watch,emcy watch(20-byte FD emergencies),sync,pdo show/map,dcf applyand the new commands.monitor --fdanddecode
now decode CAN FD frames: USDO requests and responses (--service usdo)
and FD emergencies; before, they skipped CAN FD frames. A USDO abort is
exit 11 with its SDO equivalent andusdoCode. simulate:--lss(an LSS slave; without--node-idit starts
unconfigured),--serial,--fd,--store FILE(store and restore,
LSS store) and--program(program download objects with an in-memory
program).- JSON: new result and record shapes in the schemas (additions only,
schemaVersion1.0); new error codeslss_refused,lss_conflict,
no_node_id,program_failed,boot_failed,mpdo_inactive.
Verification:
- In-process tests of every new command against go-canopen nodes on the
virtual bus with the race detector: LSS slaves (unconfigured and
configured, with and without a store), MPDO producer and consumer,
store/restore and program download devices, the CiA 302 boot-up with
and without the LSS step, CANopen FD nodes over USDO; JSON output
validated against the schemas; whole-module coverage ≥ 90 %. - End to end on vcan0 (Linux 7.0, CAN FD MTU): two unconfigured
simulate --lssprocesses found bylss fastscanand booted byboot --lss; asimulate --fdprocess operated over USDO (sdo read,nmt --wait,program download,scan) whilemonitor --fddecoded the
USDO traffic. - Interop: the existing suite against CANopenNode, Lely CANopen and
python canopen passes on the canopen-interop v0.2.0 images (pinned by
digest; contract 1.1 only adds things) in CI on amd64 and arm64. The
new commands have no interop scenarios yet.
v0.1.1
Date: 2026-10-29
Previous release: v0.1.0
Built on go-canopen v0.2.0 (was v0.1.0).
sdo readandsdo writewith--blocknow handle empty values. A block
transfer of 0 bytes may end without a data segment: Lely's SDO server sends
such an upload, python canopen's client such a download. go-canopen v0.1.0
read that end message as an out-of-order segment and timed out; v0.2.0
accepts it.- The interop suite pins the canopen-interop v0.1.0 images by digest.
v0.1.0
Date: 2026-10-29
Previous release: none
Summary
First release of canopenctl, a command-line toolkit for CANopen networks
built on go-canopen and go-canbus v0.7.0: monitor and decode traffic, SDO,
NMT, heartbeat, EMCY, SYNC, TIME, PDOs, EDS/DCF files, CiA 402 drives and
simulated nodes, on SocketCAN, serial-line CAN adapters and an in-process
virtual bus.
Additions
monitordecodes live traffic as CANopen messages (NMT, SYNC, TIME,
EMCY with the meaning of its code, PDOs, SDO with segmented and block
transfers attributed to their object, heartbeat, boot-up, node guarding,
LSS), filtered by--nodeand--service;decodedoes the same for
trace files (candump, JSON Lines, pcap, pcapng, ASC, BLF, TRC).sdo read,sdo write,sdo dump: expedited, segmented and block
transfer, data types from--typeor--eds, files for DOMAIN objects,
--verify; an abort code is reported with its meaning and as exit code
11 (JSON: the error'sabortobject).nmtto one node or all, with--waitfor the heartbeat or boot-up
that confirms it;heartbeat watch(boot-ups, state changes,
timeouts);scan(device type, profile and identity of nodes 1..127).emcy watch,sync(period, count, counter) andtime.pdo show,pdo map(CiA 301 configuration sequence, checked
against--eds) andpdo watch(decoded values; passive with
--cob-id/--map).eds validate,eds show,eds convert(EDS ↔ DCF with the
node-ID),eds generate(typed Go code),dcf apply(with
--dry-run) anddcf export(a node's values into a DCF).cia402 state,enable,disable,fault-reset,quick-stop,
mode,move,velocity: a drive operated through its statusword,
each step verified; a drive fault is exit 12 with the drive's state.simulate: a complete go-canopen node from an EDS or DCF (or a
built-in device), optionally a CiA 402 drive, with ticking objects and an
emergency on request, for demos and tests.- Safety: every state-changing command needs
--yeson an interface
that is not virtual; passive commands open slcan adapters listen-only;
productions are bounded. --format text|table|jsonwith JSON Schemas (schemas/), JSON Lines
streams, stable exit codes (docs/exitcodes.md).
Verification
- In-process tests of every command against go-canopen nodes (CiA 401 I/O
module, built-in device, CiA 402 drive) on the virtual bus, with the race
detector; golden JSON validated against the schemas; ≥ 90 % coverage. - End to end on vcan0 (Linux 7.0): simulated node and drive processes
operated by canopenctl processes. - Interop on vcan0 against CANopenNode v4.1, Lely CANopen 2.3.5 and python
canopen 2.4.1 (canopen-interop): canopenctl against their devices, their
clients againstcanopenctl simulate, their EDS checkers against