Skip to content

v0.9.0: dead Z-Wave nodes

Choose a tag to compare

@petergCA petergCA released this 24 Oct 23:01
· 3 commits to main since this release

Dead Z-Wave nodes

  • Dead nodes are flagged. A Z-Wave node that the Z-Wave JS driver has marked dead (its Node status sensor reads dead) now raises an incident, just like an unavailable entity. The incident is named after the device, uses reason: dead, and clears when the node comes back.
  • New option (opt-in): "Ping quiet mains Z-Wave nodes every (hours)". The driver only notices a dead node when a message to it fails, and nothing ever sends a repeater or an idle plug anything, so one can sit dead while still reading alive. With this set, Sentinel pings each mains node it hasn't heard from in that many hours, at most once per interval and 5 per 5-minute tick. A dead node fails the ping and gets flagged. Default 0 (off); 24 suits most homes.
  • Auto-recovery, when enabled, now pings dead nodes as well.