v1.0.1 — Bug fixes
Micro-Air EasyTouch — v1.0.1
Bug fixes
-
UI bounce-back after mode change — Entity now applies optimistic state immediately before sending the BLE command, so the climate card reflects the new mode during the status-suppression window instead of snapping back to the old state.
-
Spurious "Fan mode is not valid" toast on HA-initiated commands — Optimistic update ensures
fan_modesandfan_modeare consistent when the UI card refreshes, preventing the frontend from sending a staleset_fan_mode("")call. -
Spurious "Fan mode is not valid" toast on device-initiated mode changes — When the physical thermostat changes mode without an HA command,
hvac_modeandfan_modeno longer change in the same state write. The currentfan_modeis preserved (if still valid in the new mode) on the transition poll; the correct device fan speed syncs on the following poll. This prevents the native climate card from interpreting a two-field simultaneous change as a user action and issuing a blankset_fan_modecall.