  • Vibration measurement with an IEPE accelerometer alongside the microphone — see docs/VIBRATION_GUIDE.md
  • Inputs and Sensors window (Settings → Input Channels): a role per input (Mic, Accel X/Y/Z, Accel uniaxial, Off), live level meters, per-axis calibration (handheld calibrator or datasheet) with date and method
  • Accelerometer signal chain: high-pass, integration to velocity / displacement, ISO 8041 weightings (Wb, Wc, Wd, We, Wf, Wh, Wj, Wk, Wm), DIN 4150-2 KB weighting, band limit; detectors for RMS, peak, a_w,rms, MTVV, VDV, crest factor, PPV with dominant frequency, KB_Fmax / KB_FTr, vector sum, A(8), 1/3-octave spectrum
  • Measurement profiles for structure-borne sound, machinery, whole-body health and comfort, hand-arm, building perception and building structural
  • Assessment with editable reference values (EU / Germany, ISO 20816-3, DIN 4150-2, DIN 4150-3) and a status dot in the new Vibration panel below the SPL meter
  • Timeline vibration traces, CSV vibration columns, JSON settings with roles, calibration and limits
  • Multichannel WAV recording with roles and calibration in the file; file playback uses them
  • HTML vibration report (Ex-/Import → Save Vibration Report…)
  • REW Measurement Sequencer (Tools → REW Measurement Sequencer…): runs a list of Room EQ Wizard sweeps through REW's REST API with per-step output, second output / invert, inputs, level, sweep, repetitions, timing reference, protection, group and wait for me prompts; dry run, pause, abort, loops, error policy; REW's settings restored afterwards. SPLMeter measures every sweep (LAeq … LCpeak, vibration per axis) and saves the run as CSV and JSON, with a timeline marker per sweep — see docs/REW_SEQUENCER_GUIDE.md
  • FFT source selector (mix, Dual 1+2, or a single input) replaces the Dual FFT toggle; v3.5.2 settings load unchanged
  • The standalone app now accepts devices that open more than 8 inputs (up to 32); before, they fell back to a single input
  • Default behaviour without accelerometer roles is unchanged (bit-identical SPL results, verified by regression tests)