Skip to content

Releases

Innoxel Master 2 1.2.1

Choose a tag to compare

@prusuino prusuino released this 22 Nov 15:05
  • Quick taps no longer switch the wrong way. Several commands for the same master arriving at once (tapping a switch quickly in the UI, two automations) could all read the old state and all press the key, so an output ended on when it should be off or the other way round. Commands now run one at a time; each one reads the state the previous one left.
  • Ready for Home Assistant 2027.8. The channel devices name the master device by its registry id (via_device_id) instead of the identifier Home Assistant reports as deprecated. Older Home Assistant versions keep the previous way.

Innoxel Master 2 1.2.0

Choose a tag to compare

@prusuino prusuino released this 22 Nov 12:49
  • New channel type: sensor. Add sensor takes an output address and gives a binary_sensor with the state of that output, without a key. It is meant for what the master reports among the outputs but Home Assistant should not operate: a 230 V input module (NOXin-0800h, which is addressed like an output) or an output the master uses as a flag, such as the night setback or the release of a weather function.
  • Faster. The state of the outputs and dimmers is read every second instead of every two, so a change at a wall button shows up within a second. After a command from Home Assistant the new state is read at once instead of after a fixed pause of 0.3 seconds; the master confirms a key only when it has carried it out. Measured on a Master 2 (REV 09.23) through a Moxa NPort: one state poll takes about 45 ms, and the new state is in Home Assistant about 0.1 seconds after the key.
  • The README names the firmware the interface needs (9.00 or newer, according to Innoxel's documentation of its remote control).

Innoxel Master 2 1.1.0

Choose a tag to compare

@prusuino prusuino released this 22 Nov 12:23
  • Diagnostics download. The entry's menu under Settings → Devices & services offers Download diagnostics: the firmware revision, the raw state and weather answers of the master, the channels with their addresses and the entities with their current state. The address of the serial device server is redacted. The bug report form asks for the file.

Innoxel Master 2 1.0.0

Choose a tag to compare

@prusuino prusuino released this 22 Nov 12:03
  • French and Italian. The dialogs, entity names, the action and its error messages are translated into French and Italian, next to German and English.
  • Documentation. The README follows the structure of the Innoxel Master 3 integration and describes how the serial device server has to be set up (serial settings and operating mode of a Moxa NPort 5110), how blinds behave, how often the master is read and how INNOXEL Setup stays usable.
  • Tests. The serial protocol, the setup dialog, the channel dialogs, the entities, the connection switch and the action are tested against a stand-in master; a workflow runs the tests on every change.
  • Quality scale: Bronze, self-assessed; the per-rule status is in quality_scale.yaml.
  • Release file. A release now carries innoxel_master2.zip, which HACS and the Home Assistant Marketplace download.
  • The Home Assistant Marketplace lists the integration under Hubs & protocols → Building automation, Blinds & curtains and Lighting.
  • Nothing changes in how the integration works compared with 0.1.0.

Innoxel Master 2 0.1.0

Choose a tag to compare

@prusuino prusuino released this 22 Nov 11:44

First public version of the integration for the Innoxel Master 2 (NOXmaster), which is reached through a serial device server such as a Moxa NPort 5110 in TCP server mode.

Early development version. Tested on a bench with one Switch 8 module. Dimmer, blind and weather support follow the protocol but have not been verified on real hardware yet.

What it does

  • Local and direct: talks the serial protocol of the master through a serial device server on your own network — no cloud, no extra gateway software.
  • Works like a wall button: Home Assistant presses the keys you programmed in INNOXEL Setup and reads the real state of the outputs back.
  • Switches and lights with true state: a command only presses the key when the output is in the other state, so two automations never cancel each other out.
  • Blinds: one key impulse runs a blind to its end position, an impulse while it moves stops it.
  • Outputs found for you: leave the output address empty and the integration detects which output a key switches.
  • Weather station: temperature, wind speed, sun brightness east/south/west, twilight and rain appear on their own when a weather station is connected.
  • Long key presses: the send_key action sends an impulse, or press and release separately.
  • INNOXEL Setup stays usable: one switch releases the connection to the device server while you reprogram the master.

Installation

Add https://github.com/prusuino/ha_innoxel_master2 as a custom repository (type Integration) in HACS or the Home Assistant Marketplace, install Innoxel Master 2 and restart Home Assistant. Setup and the device-server settings are described in the README.

For the Innoxel Master 3 use ha_innoxel_master3 instead.

No warranty: the integration controls real hardware. Test it in your own installation before you rely on it.