Marstek Venus Surplus Control 1.3.0

Choose a tag to compare

@prusuino prusuino released this 21 Nov 18:01
  • The Venus takes over from a charging first battery step by step. When the Venus was allowed to charge while the first battery was still charging itself – with Venus charges from first battery SoC set low, for example – it asked for the whole surplus at once. That surplus was what the first battery was taking, and a battery that follows the meter needs a few seconds to give way: for a moment it discharged into the Venus, the charge stopped, the surplus was back and it started again, several times in a row. The Venus now starts with what the first battery leaves, at least 200 W, and adds 200 W per tick while the first battery is still charging. A first battery that takes nothing, or is at its charge limit, changes nothing: the Venus gets its power in one step as before. The decision attributes show it as charge_soft_start. Thanks to @VIMVa for the screenshots (#4).
  • The reason Surplus, first battery full is now Surplus, first battery at the set SoC. The reason appears once the first battery has reached Venus charges from first battery SoC. With that setting at its default of 85 % "full" was close enough; with a low value the sensor said "full" about a battery at 5 %. Only the text changes, in all six languages; the state behind it (charge_ok) is the same, so automations keep working.
  • Quality scale: Silver. The tests now cover more than 95 % of the code (watchdog, discharge cap guard, Modbus self-heal, diagnostics), and the test workflow fails below that; every platform declares its parallel updates. Nothing changes in how the controller decides.

Marstek Venus Surplus Control 1.2.1

Choose a tag to compare

@prusuino prusuino released this 19 Nov 21:56
  • The Home Assistant Marketplace lists the integration under Energy → Solar & batteries. Nothing changes in how the integration works.

Marstek Venus Surplus Control 1.2.0

Choose a tag to compare

@prusuino prusuino released this 19 Nov 16:20
  • The export guard of a Venus that is the only source is a setting. New number Export guard (Venus alone), 0–50 W, default 10 W: how far the Venus stays below the house demand when no first battery covers the rest. Until now the guard was 3 % of the demand (5 to 15 W), which with the 10 W steps came to the same at night loads; a house that draws 900 W now gets 890 W instead of 880 W. Set it to 0 for the least import, higher if nothing may be exported. Suggested by @VIMVa (#4).

Marstek Venus Surplus Control 1.1.0

Choose a tag to compare

@prusuino prusuino released this 19 Nov 08:34

Faster on large loads, calm on small ones as before. Thanks to @VIMVa for the observations (#4).

  • A large load starts the discharge within two ticks. The discharge waited for the surplus mean to fall below 100 W, and next to a first battery that delivers nothing (full, empty reserve, not allowed to cover peaks) for another six ticks. With a washing machine heating up that was one to two minutes of import. Now: when the house needs 400 W or more and that much comes from the grid for two ticks in a row, the Venus starts at once, whatever the mean still says. While the house needs that much, the mean does not stop it either. Smaller loads take the calm way as before, so a ping-pong of a few hundred watts is still smoothed out.
  • A charging Venus no longer charges from the grid when a load switches on. The charge command follows the mean; when a load switched on, the Venus kept charging on the old mean for up to a minute. A first battery that covered the load already lowered the command (0.9.10). Now grid import does the same: more than 100 W of import while charging takes that import plus 50 W off the command in the same tick (and stops the charge at once when nothing is left); the command comes back by up to 100 W per tick. A charge does not start on the mean alone either while the grid delivers at that moment.
  • The waits before a discharge are times, not ticks. First battery has been delivering 150 W and first battery delivers nothing although the house imports waited six ticks: 90 seconds with a tick of 15 s, three minutes with the default of 30 s. Both are now 90 seconds on every tick length (never less than two ticks).
  • Less import when the Venus is the only source. At night with an empty first battery the Venus stayed 10–30 W below the demand and left out rises of less than 20 W, which added up to 30–40 W of steady import. The export guard is now 3 % of the demand (5 to 15 W) and rises from 10 W are followed. Expect about half the import, and a few watts of export for a tick when a load switches off.
  • The attributes of the status sensor show grid_import_w and fast_start.

Marstek Venus Surplus Control 1.0.1

Choose a tag to compare

@prusuino prusuino released this 16 Nov 19:54
  • The integration is now called Marstek Venus Surplus Control. "Venus" alone is also the name of other products in the Home Assistant world; the full name says which battery this is for. Only the displayed name changes: the domain venus_surplus, the entities, the card and the repository stay as they are, so nothing has to be set up again.

Venus Surplus Control 1.0.0

Choose a tag to compare

@prusuino prusuino released this 16 Nov 18:01

The first stable release. The controller runs on two systems of different build, one with a large inverter-coupled battery and a Venus A with its own panels, one with a grid meter and two plug-in batteries as the first battery; the 0.9 releases were shaped by what those two showed.

  • The reason names a low Venus SoC at the bottom end as well. A discharge stops at 12 % and starts again from 15 %. In between, and when the Venus went to standby by itself at its own floor (14 % on a Venus A), the reason read No condition met although the house drew power and only the empty Venus kept it from discharging. It now reads Venus SoC too low when the SoC is the only thing in the way. The decisions are unchanged.
  • README: the highlight on parallel charging names all three ways to "Venus first", including the threshold on today's forecast that you set.

Venus Surplus Control 0.9.12

Choose a tag to compare

@prusuino prusuino released this 16 Nov 17:54
  • Removing an entry removes its stored state. The file under .storage with the controller state and the values set on the device page stayed behind when an entry was deleted. It is now removed with the entry.
  • Changing the Force Mode entity under Configure moves the entry's key with it. One entry per Venus is checked by that entity; after a change the check still looked at the old one. Picking an entity that another entry already runs is refused.
  • One reload instead of two when Configure removes an optional entity that was set up in the first place: data and options are now written in one step.
  • SECURITY.md describes what the integration reads, changes and stores.

Venus Surplus Control 0.9.11

Choose a tag to compare

@prusuino prusuino released this 16 Nov 11:23
  • The projection for "Venus first" now checks the forecast. The projection extends the surplus of this moment to sunset: if the first battery would be full long before then, the Venus may charge in parallel. In autumn and winter the surplus does not last that long. Seen on a real system at noon in November: 2.7 kW of surplus, 8.4 kWh missing in the first battery, 5.6 kWh of forecast left for the day. The projection said "full in three hours", the Venus charged in parallel until sunset and took 1 kW away from a first battery that could not be filled anyway. With a forecast set up, the projection now only starts when the remaining forecast, less what the house needs until sunset, covers what the first battery misses with 10 % margin, and it lets go again when the forecast falls below that. Without a forecast it works as before.

Venus Surplus Control 0.9.10

Choose a tag to compare

@prusuino prusuino released this 16 Nov 10:46
  • Charging no longer stops for a tick when the surplus falls. The charge command follows the averaged surplus. When clouds took the surplus down, the Venus kept charging on the old average for a moment, the first battery started to discharge into it, the guard against that stopped the Venus, and a tick later it started again at the old power: on, off, on. The command is now lowered by what the first battery discharges plus 50 W and comes back in steps once it no longer does. Seen on a real system: 1000 W commanded, the first battery discharged 221 W, the Venus now carries on at 600 W instead of stopping. The guards are unchanged for the rest: more than 350 W, or more than 200 W over two ticks, still stops the charge, and starting is as strict as before.
  • Reason corrected. Surplus, first battery charges first (new in 0.9.8) also showed while the first battery was discharging. It now only shows when the first battery is not discharging.

Venus Surplus Control 0.9.9

Choose a tag to compare

@prusuino prusuino released this 16 Nov 10:22
  • A first battery at its charge limit leaves the rest to the Venus. A first battery can only take so much: its rated power, or less with cold or nearly full cells. Surplus above that was exported on an ordinary day, because the Venus waited for the first battery to reach its level. The controller now recognises the limit by itself, without a setting: the first battery charges at a steady power for six ticks while at least 400 W more surplus stands than it takes. The Venus then charges with that rest only (reason Surplus, first battery at its charge limit). As soon as the first battery takes clearly more or less than before, it is not at a limit any more and goes first again. Worked out and covered by tests, not yet seen on a real system with a small first battery.