Repository navigation
ToneStrand 1.0.0-beta.3
Pre-release
Pre-release
·
127 commits
to main
since this release
New
- Command Center on the pedal (HX Stomp), now complete: a Command Center tab in the Controllers card with a
trigger grid (Instant 1-6, FS 1-5, EXP 1-2) and an editor per trigger for every command type (MIDI CC,
CC Toggle, Note On, Bank/Program, MMC, Hotkey, HX Preset, HX Snapshot, HX Looper, pedal MIDI CC). Each snapshot
keeps its own values (the preset's snapshot bar picks which), CC Toggle and Hotkey have a Momentary switch, and
the footswitch gets its name from the command. On the loaded preset a change reaches the pedal at once (kept by
"Save on pedal"). The slot order and every argument layout were checked against another editor's traffic on a pedal. - A
.hlxsent to the pedal carries its Command Center (waits held to the pedal's limit of 20, Momentary
flags, each snapshot's own values). - Input and output panels follow the layout of an effect's: icon tile, jack picture, one row of settings.
Guitar In-Z and Guitar Pad moved from the Controllers tab to the Input block's panel. - Block panels have one height; an amp with a cab is two sections of it, each with its own photo and a
line between. A model's description is behind a (?) next to its name. - Tools:
--commands,--cc-compare,--cc-raw,--cc-reload,--box-proxy(log what another editor sends
the pedal),--dump-loaded,--send-hlx,--cc-snap,--put-slot(see docs/BUILDING.md).
Fixed
- A pedal document's Command Center was read from the first element of each row; the pedal's own rows start with 0
and keep the type in a separate list, so every command except HX Preset showed as empty. Both are now read and
written as the pedal does. - Command Center footswitch labels: the pedal's FS 1 to FS 5 are slots 6 to 10 (FS 4 / FS 5 were wrong).
- Changing a Command Center command on the loaded preset could jump back to "None" or change again: the window
was refreshed from the pedal after every edit and an older refresh overwrote the next change. It now keeps
what you set and only reloads if the pedal kept something different. The same race affected the other live
edits (guitar input, effects, moves, snapshots, controllers, footswitches): when edits are sent in a row, only the
newest copy of the preset from the pedal is shown.
Known gaps
- Command Center is read and edited on the HX Stomp only; other units get a note that it wasn't carried over.
- The names and defaults of the Bank/Program and HX Looper switches, and HX Looper's press and release/hold fields,
are not checked on a pedal. - The
.hlxeditor's amp and cab panel keeps the older single-column layout. - Command Center changes use the whole-preset write (op 21), not the pedal's own live commands.
Install
- ToneStrand-Setup-1.0.0-beta.3.exe: installer (current user, no administrator rights).
- ToneStrand-1.0.0-beta.3-windows.zip: portable, just unzip and run.
- Needs Line 6's HX Edit installed on the same computer.
- Windows SmartScreen may warn because the program is not code-signed: choose More info, then Run anyway.