You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Setting "Include internal system variables" in the connection node.
The CCU keeps system variables of its own that its WebUI hides - the ones
it creates for devices, such as svHmIPRainCounterToday_… of an HmIP
weather station, and the watchdog variables. They were never listed: the
script that reads the variables (homematic-rega) skipped every internal
variable. homematic-rega 2.1.0 lists them and marks them; with the new
setting on they appear in the sysvar node's list and its messages like any
other variable. Off by default, as a CCU with many HmIP devices has several
per device. The alarm and service messages (Alarmmeldungen, Servicemeldungen) are listed either way, as before, and now carry their
real timestamp. (#184, @drMaxxi)
Commits since v4.11.1
4.12.0 - internal system variables on request (0a2eefd)