You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
openccu-lite: system variables and programs from the Logic addon. On
openccu-lite the ccu-sysvar and ccu-program nodes stayed disconnected and answered every message with an error, because the system
has no ReGaHSS. The Logic addon now offers the variables and programs as
devices of its interface Logic through the system's lite-rpc, and the nodes
use it: a variable or program is found by its name, as on a CCU, so flows
written for a CCU keep working after the switch once the variables and
programs were imported into Logic. Values arrive at every write (with Emit changed values only, changes only), writes take a list entry or a
logic value also by its text, a program is switched by true/false and
started (the first Then, as the CCU's Start) by anything else. The
editor lists the variables and programs; ccu-get-value, ccu-switch and ccu-mqtt find them as well. Without the addon the nodes show Logic addon
not installed, and the addon installed while Node-RED runs is taken
without a deploy.
openccu-lite: every interface the system lists. The connection
followed only the radio interfaces it knows; an addon's interface (such as
Logic's) was never seen. It now follows every interface lite-rpc lists, an
addon's without a checkbox; its devices and datapoints can be used with the
value, event and rpc nodes like those of any interface.
Commits since v4.13.0
4.14.0 - system variables and programs on openccu-lite (c85ee79)
docs: system variables and programs from the Logic addon on openccu-lite (05d24cb)
feat(openccu-lite): sysvar and program nodes on the Logic addon's interface (103a6b4)