Skip to content

v4.17.1

Latest

Choose a tag to compare

@github-actions github-actions released this 29 Nov 09:48

Fixed

  • A taken callback port crashed Node-RED. When the BINRPC listening port
    of a ccu-connection node was already in use - by a second connection node
    with the same port, as a flow imported with a copy of the connection node
    brings it, or by another process - Node-RED ended with
    listen EADDRINUSE at every start (on RedMatic: only the safe mode was
    left). Since 4.1.0 the error of the BINRPC callback server went unheard.
    Now only that connection fails: its nodes show port <n> in use, the log
    names the port and the connection node holding it, and the rest of the
    runtime keeps running. The editor marks a connection node whose listening
    port another connection node uses. Reported by HA_Beginner
    (homematic-forum).

Commits since v4.17.0

  • 4.17.1 - a taken callback port no longer crashes Node-RED (7c1ae89)
  • docs(changelog): 4.17.1 (90f2698)
  • docs(changelog): a taken callback port no longer crashes Node-RED (0346cb9)
  • fix(connection): a taken callback port fails the connection, not Node-RED (bcc4683)