The TSF-85 C++ SDK drops libserialport for the native serial transport the grippers SDK already used, now shared by both SDKs, so it builds with MSVC on Windows. The grippers SDK ships its device profiles as a data file.

TSF-85: changes since v3.1.0

  • No libserialport. The C++ SDK uses the serial transport it now shares with the grippers SDK in common/. Nothing to install besides a compiler and CMake, and the SDK builds with MSVC on Windows (#62, #70, #65).
  • Port names are opened as given. The SDK no longer resolves symlinks itself; the OS follows udev aliases such as /dev/rq_tsf85_0 when it opens the port, and COM4 stays COM4 on Windows (#65).

Fixes

  • getFirmwareVersion() got no reply: its request went out with an uninitialized CRC byte, which the sensor ignored (#65).
  • start() after stop() resumes collection; it used to start nothing (#65).
  • getFirmwareVersion() returns at once when collection has stopped or the sensor is lost, instead of waiting out its timeout (#65).
  • Writes to the sensor no longer stall about 100 ms in drain() on its USB CDC port (#65).

Grippers: changes since v3.1.0

  • Device profiles as data. The shipped profiles live in sdk_cpp/data/device_profiles.json, installed with the SDK, so non-C++ consumers read the same values as the C++ code; device_profile.hpp is generated from it (#68).
  • Robotiq/gripper/device_profile_names.hpp holds the lookup of a profile by name, profiles::profileNamed (#80).
  • Errors raised after a port opens name the port (#65).

Compatibility

  • Grippers: source-compatible with v3.1.0. The public API is unchanged apart from additions. find_package(grippers 3) is unchanged.
  • TSF-85: source-compatible with v3.1.0; RobotiqTactileSensor.h lost only its libserialport include and private members. Building the SDK needs a C++17 compiler and CMake 3.16, as the grippers SDK does, while its public headers stay C++11-clean for the code that uses them. Supported hardware and firmware are unchanged from v3.1.0.

Full changelog: v3.1.0...v3.2.0

robotiq-sdk 3.1.0

Choose a tag to compare

@ebarnett3 ebarnett3 released this 19 Nov 21:39
f186755

Adds the Hand-E 100 profile and the 2F knuckle-angle conversions to the grippers SDK, and shows the TSF-85's hardware revision and serial numbers in quick_connect.

TSF-85: changes since v3.0.0

  • quick_connect shows the hardware revision and serial numbers. At connection and in the monitor header, it lists the model, hardware revision, serial number and production year of the hub and of each finger. Finger serial numbers are now sequential, so the label no longer gives the hardware revision. This needs firmware 2.1.0 or later (#71).

Grippers: changes since v3.0.0

  • Hand-E 100. profiles::kHandE100 scales speed and opening over the 100 mm stroke (#60).
  • Knuckle angle conversions. units::knuckleAngleToRegister and units::knuckleAngleFromRegister convert between gPO and the 2F knuckle angle in radians, linear over the whole byte. DeviceProfile gains knuckleAnglePerCount and hasKnuckle(), and units::valueInSpanFromRegister is the inverse of registerFromSpan (#63, #66).
  • move_gripper takes the gripper model as an optional third argument: 2f85 (default), 2f140, hande, hande_100 or hande_c10 (#61).
  • Good control practices: how to release an object without leaving the gripper stuck in the grip (#64).
  • Build: the GoogleTest download the tests fall back on is pinned with a SHA-256 (#75).

Compatibility

  • Grippers: source-compatible with v3.0.0. The public API is unchanged apart from additions. DeviceProfile's new last member has a default, so profiles written with the six v3.0.0 values still compile and convert as before; their knuckle conversions return std::nullopt. find_package(grippers 3) is unchanged.
  • TSF-85: the SDK headers are unchanged, and quick_connect only gains output. Supported hardware and firmware are unchanged from v3.0.0.

Full changelog: v3.0.0...v3.1.0

robotiq-sdk 3.0.0

Choose a tag to compare

@ebarnett3 ebarnett3 released this 05 Nov 02:35
46754ee

The first release of robotiq-sdk, the public repository for the Robotiq SDKs. It was robotiq/tactile_sensors until now, and it gathers one folder per product:

Folder Product Was
tsf/ TSF-85 tactile sensor: C++ SDK, quick-start tools and web viewer, firmware tools the root of robotiq/tactile_sensors, last release v2.1.0
grippers/ Grippers C++ SDK (2F-85, 2F-140, Hand-E, …) Robotiq/grippers, last release v1.3.0

The grippers SDK came with its full history, so git log and git blame under grippers/ reach back to its first commit. (#31, #34)

⚠️ What breaks: paths

The code itself has no breaking change: the TSF-85 SDK and tools behave as in v2.1.0, and the grippers SDK API is the one of v1.3.0. What changed is where things live.

  • TSF-85: everything moved into tsf/. Use cd tsf/sensor_quickstart to run the tools, and tsf/sdk_cpp as the CMake source folder. The old robotiq/tactile_sensors URLs redirect here.

  • Grippers: add robotiq-sdk as the submodule, and point CMake at the grippers/ folder in it:

    # before: git submodule add https://github.com/Robotiq/grippers third_party/grippers
    add_subdirectory(third_party/grippers/sdk_cpp)
    # now:    git submodule add https://github.com/robotiq/robotiq-sdk third_party/robotiq-sdk
    add_subdirectory(third_party/robotiq-sdk/grippers/sdk_cpp)

    With an installed package, update find_package(grippers 1) to find_package(grippers 3).

  • Build from a full checkout. Each SDK reads the version from the repository's root VERSION file, through cmake/RobotiqSdkVersion.cmake. A copy of sdk_cpp/ on its own stops at configure with "build this SDK from a full robotiq-sdk checkout". (#34)

Projects that pin a tag or a commit of tactile_sensors or grippers keep building as they are, and can move when they choose.

Versioning

One version for the whole repository, kept in the root VERSION file, and one vX.Y.Z tag per release. 3.0.0 is above every earlier tag of both repositories: TSF-85 goes from 2.1.0 to 3.0.0, and grippers from 1.3.0 to 3.0.0.

Semantic versioning applies across the repository. A breaking change to a documented API is deprecated first, and lands only in a planned major release of the whole repository. The grippers CMake package keeps SameMajorVersion compatibility, so find_package(grippers 3) accepts every 3.x release. See "Versioning" in the README. (#34)

TSF-85: changes since v2.1.0

The launchers install Python, and the viewer runs offline

  • Python is installed for you. When Python is missing, or older than 3.10, the launchers install Python 3.12 on Windows, macOS and Linux. They ask first, and say that installing accepts the Python license. (#20, #24)
    • Windows: installed for the current user, with no admin rights, through winget or the python.org installer. The installer's signature is checked before it runs. (#20, #24)
    • macOS: the python.org package, installed only if the Python Software Foundation signed it. (#20)
  • The minimum Python version is now 3.10 (was 3.7), because gripper control needs pyrobotiqgripper. An existing .venvSimpleCheck built with an older Python is rebuilt on the next launch. (#20)
  • Offline after the first launch. Plotly 2.35.0 is now bundled in web/vendor/, instead of loaded from a CDN. The launchers no longer run pip when the requirements have not changed. (#20)
  • License texts for Plotly, three.js and the libraries bundled in Plotly are in web/vendor/. (#20, #24)

Fixes

  • macOS: ./run_web_viewer.sh, the command the READMEs give, now runs the macOS launcher instead of failing with apt-get: command not found. (#20)
  • macOS: in Safari, the gripper Activate button responds to clicks on its label. (#20)
  • Web viewer: the page no longer waits at startup on a machine with slow reverse DNS, which held it for more than 20 s on some Macs. (#35)

Compatibility

Unchanged from v2.1.0:

  • Hardware version 2.1: firmware 1.1.8
  • Hardware version 2.2: firmware 2.2.0

Grippers: changes since v1.3.0

  • New guide: Good control practices. The docs after it are renumbered: the robust example walkthrough is now 05, and embedded builds 06. (#38)

The API is the one of v1.3.0, so code that builds against 1.3.0 builds against 3.0.0.

CI

  • Grippers: the same checks as in Robotiq/grippers, run from the repository root: builds and tests on Linux, macOS and Windows, embedded builds, coverage, API docs, format and doc snippets. (#34)
  • TSF-85: the C++ SDK in Release, and a smoke test of the web viewer with simulated data on Linux, macOS and Windows, with Python 3.10 and 3.13. (#35)

Full changelog: v2.1.0...v3.0.0

v2.1.0

Choose a tag to compare

@ebarnett3 ebarnett3 released this 06 Oct 22:43
afea4e3

⚖️ License change

The C++ SDK (sdk_cpp/) is now licensed under BSD-3-Clause instead of GPL-3.0. The source file headers now carry BSD-3-Clause text and SPDX tags, matching the root LICENSE. Projects that link the SDK, statically or dynamically, are no longer bound by GPL terms.

Exceptions:

  • firmware/bootloader_host.py is a derivative of a third-party GPL-3.0 project and stays GPL-3.0. The full license text is in firmware/LICENSE, and the carve-out is documented in the root and firmware/ READMEs. (#9)
  • sensor_quickstart/web/vendor/ bundles three.js r160 (three.module.js, OrbitControls.js) under its own MIT license, with inline SPDX headers. (#11)

Web viewer

A browser-based dashboard for the TSF-85, started with run_web_viewer.sh, run_web_viewer_mac.sh or run_web_viewer.bat (--help lists the options). It runs fully offline.

  • Overview: one column per finger, with its pressure pad above its dynamic trace. Dynamic Sensors and IMU tabs give the detailed views.
  • Pressure heat maps drawn at the sensor's physical aspect ratio. Choose a Per taxel or Interpolated view, and use Reset Baseline, Unzeroed and Adaptive scale. (#10, #15)
  • Dynamic traces scale automatically from ±0.1 mV up to full scale (±1.024 mV), and short taps stay visible. (#15)
  • 3D gripper view (optional): the fingertips are drawn from IMU data, fingers-up or fingers-down orientation is detected automatically, and a warning appears when tilt can't be measured. When an FT-300 is connected, its force and torque are shown too. (#11, #15)
  • Gripper control (optional): position, speed and force sliders, Open/Close/Activate buttons, object detection, and fault display and reset for Robotiq grippers, through pyrobotiqgripper. The gripper is detected automatically on USB serial adapters, or set with --gripper-port DEV; --no-gripper turns it off. (#15)

Other changes

  • macOS: added launch scripts; updated the top-level README. (#6)
  • C++ SDK: the CMake project version now matches the release (2.1.0). (#17)

Requirements

  • New optional dependency: pyrobotiqgripper>=3.3.14, installed only on Python 3.10+. On older Python versions the viewer runs without the gripper controls.

Compatibility

Unchanged from v2.0.0:

  • Hardware version 2.1: firmware 1.1.8
  • Hardware version 2.2: firmware 2.2.0

You can tell the hardware version from the serial numbers on the fingers: 21xxx is v2.1 and 22xxx is v2.2. quick_connect.py prints the firmware version.

Full changelog: v2.0.0...v2.1.0

v2.0.0

Choose a tag to compare

@jkski-robotiq jkski-robotiq released this 15 May 14:55
c0ba96e

Software to communicate with the TSF-85 sensors

Compatable with:
Hardware version 2.1 - Firmware 1.1.8
Hardware version 2.2 - Firmware 2.2.0

Hardware version can be determinded from the serial numbers on the fingers. numbers starting with 21xxx are v2.1 and 22xxx are v2.2.

This release includes:

  • python api for communication and connecting with sensors
  • python quick_start scripts
    -C++ sdk
    -bootloader to upgrade firmware from version 1.0.6 to 1.1.8 for hardware version 2.1

Firmware can be determined from the terminal ouputs from the quick_connect.py script.

v1.0.0

Choose a tag to compare

@mbegin-robotiq mbegin-robotiq released this 02 Mar 19:56
58dcb37

Initial release of the TSF-85 SDK and quickstart utilities.

Firmware compatibility: 1.0.6

What's Included

  • C++ SDK (sdk_cpp/) — Lightweight, threaded, callback-based API for direct sensor access. Includes terminal visualizer and diagnostic tools.
  • Python Quickstart (sensor_quickstart/) — Quick-connect terminal monitor and browser-based web viewer with real-time heatmaps, dynamic FFT, and IMU plots.
  • Qt Desktop UI (tactile_sensor_ui/) — Full-featured GUI application for real-time visualization and data logging (runs via Docker).
  • Platform Utilities (utils/) — udev rules, device detection, and setup scripts for Linux and Windows.