You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
ADI-2/4 Pro SE: Line Out Ref Level has five values (+1, +7, +13, +19, +24 dBu). 0.2.0 and
earlier used the ADI-2 Pro's four (+4, +13, +19, +24 dBu), so the level was shown and set one
step off. The order is taken as ascending, like the SE's input list in RME's table; not yet
checked on an SE.
open-adi2-control get line ref printed a phones level name instead of the line level.
Changed
Device ID 0x73 is shown as "ADI-2/4 Pro SE / Pro EX" (the ADI-2/4 Pro EX is expected to use the
SE's ID).
A select value the unit reports that RME's MIDI table doesn't list (for example settings the
ADI-2/4 Pro EX added) is shown as #n instead of (n) or an empty field; the command line
prints it as #n and accepts #n for set.