Repository navigation
v0.2.0 — DICOMweb access, saved measurements, cine and MIP/MinIP
The three gaps that mattered
This release closes the three capabilities the comparison against paid viewers put at the top of
the list: reaching a study over the network, keeping what you measured, and watching/reformatting a
stack properly.
Open a study over the network (DICOMweb)
File ▸ Open from server… — enter a DICOMweb base URL, filter by patient / date / accession /
modality, pick a study, and it downloads into its own cache folder and opens like a local one.
QIDO-RS for search, WADO-RS for retrieval, one instance at a time with progress and a working
Cancel. A study whose instances cannot all be fetched is reported as an error and is never opened
as if complete. No C-FIND/C-MOVE, no upload, no worklists; single-part WADO replies only.
Regions of interest that stay measured
Rectangle and ellipse ROIs (Tools menu, Ctrl+R for rectangle) report mean, population SD, min, max,
pixel count and mm² area — the area only when the file carries Pixel Spacing, never invented. An
ellipse counts the pixels it covers, not π·a·b. Regions are stored per series per slice in a local
JSON sidecar keyed by Series Instance UID: geometry and tool type only, no patient name, no paths.
Statistics are recomputed from the pixels on load, so a hand-edited file cannot make the numbers
lie. File ▸ Export measurements… writes CSV.
This is a private sidecar, not DICOM SR/GSPS — no other viewer will read these annotations. Distance
and angle measurements remain session-only.
Cine and reformats
Space loops the series (2–30 fps with [ and ]), advancing from what is on screen so a slow disk
stretches the loop instead of skipping frames; any manual step stops it. The MPR window gains a
Reformat row: nearest neighbour (invents nothing) or linear interpolation between adjacent slices,
and single-slice / MIP / MinIP over a slab thickness in millimetres, clipped at the stack edge.
What this release does not claim
- Nobody has launched the packaged app on Windows hardware. CI builds, tests (21 targets) and
packages it;docs/VALIDATION.mdrecords that as unrun. - No real PACS contacted: TLS with institutional certificates, OAuth/SMART flows, multipart WADO
replies and paging are untested; documented indocs/VALIDATION.md. - MPR remains research/experimental. Interpolation is across the slice axis only. No oblique
reformats, no volume rendering. - Not a medical device. Nothing here is validated for clinical decisions.
Install
Unzip anywhere, run clivus.exe. LICENSE, THIRD-PARTY.md and assets/ ship beside the binaries.
Provenance
Commit 9b98a55 (tag v0.2.0); 21 test targets green on Linux and on the Windows CI runner
(run 40041232270, green on the first attempt — unlike v0.1.5's four MSVC-only failures).