Repository navigation
Releases
Syndetis v0.7.0 – PROFINET Discovery & Industrial Network Diagnostics
What's new
- Start a PROFINET DCP Identify All scan from the OLED on the local Ethernet segment. The tester’s wired interface can discover replying stations without an IPv4 address.
- View advertised station details and scan counters on the OLED and the local Wi-Fi dashboard. Passive LLDP/CDP discovery remains available.
- Export scan state and counters in the browser’s JSON diagnostic report. Select Include network identifiers to include the PROFINET station inventory.
Field acceptance · November 27, 2026
The project owner discovered a Siemens SIMATIC S7-1200 using PROFINET DCP without wired IPv4, confirmed passive LLDP discovery and a 100 Mbps full-duplex link, used the mobile browser dashboard, and successfully initiated the JSON diagnostic report download. The documented scan showed zero PROFINET overflow, malformed frames, and queue drops. These observations apply to the tested PLC and network setup. See the field acceptance record.
Firmware update
Download Syndetis-v0.7.0.bin (948,560 bytes) and Syndetis-v0.7.0.bin.sha256. Verify the checksum before uploading the image through Settings → Firmware Update on an existing installation. Use a trusted image, a controlled local connection, and stable power. Follow the USB instructions for initial installation and recovery.
Hardware: WT32-ETH01 (ESP32, 10/100 Mbps) with a 128×64 SH1106 OLED. SDK: ESP-IDF v6.1. See the release manifest for source and image verification.
Syndetis v0.6.0 — Stable
Syndetis v0.6.0 — Stable
This release adds a downloadable JSON diagnostic report to the local Wi-Fi web dashboard and a dedicated Diagnostic Report entry on the SH1106 OLED.
What's new
- JSON report exported directly from the browser after receiving a valid status snapshot.
- Firmware, Ethernet link/speed/duplex, DHCP, and LLDP/CDP diagnostic data included when available.
- Network identifiers excluded by default and included only with explicit opt-in.
- Snapshot age, stale/offline state, and browser UTC export timestamps recorded.
- OLED Diagnostic Report screen directs users to the dashboard; Wi-Fi remains explicitly user-controlled.
Compatibility
- Hardware: WT32-ETH01 (ESP32 / LAN8720, 10/100 Mbps)
- Display: SH1106 128×64 OLED
- SDK: ESP-IDF v6.1
Validation
The project owner reports successful physical hardware testing and JSON report export. The source and automated test history are documented in the repository.
Firmware binary
No compiled firmware image is attached to this release. Build from source using the pinned ESP-IDF v6.1 environment and the instructions in README.md. Do not flash a source archive or reuse an old partition layout as a firmware update.