The version scheme changed with this release: the previous release was v0.0.36,
this one is v0.37.0. The leading 0.0. was never going anywhere, so the minor
number moved up and patch releases now have somewhere to go.

Added

  • SAR calculation reworked, following IEEE/IEC 62704-1: averaging is done
    once for all frequencies instead of per frequency, and is multi-threaded,
    together giving a large speedup. The new --autorange option restricts the
    calculation to the cells near the peak, a further speedup that does not
    guarantee finding the global peak. Available from Python
    (sar_calculation) and from Octave (CalcSAR.m, with autoRange,
    numThreads and progress), with a new SAR averaging tutorial.
  • Waveguide mode excitation and probe from an HDF5 mode file, complementing
    the analytic mode functions. WaveguidePort/RectWGPort accept a
    mode_file argument, the Add*WaveGuidePort methods accept a local_origin,
    and matlab/h5writemode.m (with an Octave oct-file) writes the mode files.
    Requires the matching CSXCAD support.
  • New Python port classes: CircWGPort, CoaxialPort, StripLinePort,
    CPWPort and CurvePort, with matching Add*Port convenience methods on
    the openEMS class following the existing AddLumpedPort/AddMSLPort
    pattern, plus a check_mode_purity() utility. Ports also store their time
    base, which makes plotting easier.
  • CreateNF2FFBox() (Python) accepts directions and mirror, which
    overrule the settings derived from the boundary conditions, e.g. to leave
    the face an antenna feed passes through out of the Huygens surface.
  • DelayFidelity() (Python), the time delay from the source port to the
    antenna phase centre and the fidelity of the radiated pulse, for any
    polarisation via complex weights on E_theta and E_phi.
  • Localized Mur and SA-Mur absorbers as stand-alone engine extensions, so an
    absorbing boundary can be placed inside the simulation domain rather than only
    at its edge.
  • Lumped RLC elements: series and parallel R/L/C, implemented with an
    auxiliary differential equation.
  • HDF5Dump (Python) for reading field dumps: a dump can be inspected
    before any field data is read, SetPlane/SetLine/SetRange/SetSampling
    push the selection down into HDF5 so only the requested part is read, and
    GetFieldAtFrequency() runs an on-the-fly DFT so time-domain and
    frequency-domain dumps are post-processed the same way.
  • SetLibraryArguments(), which accepts almost every option of the
    openEMS executable as a string. The Python binding uses it, so engine
    selection and the debugging options are now reachable from Python.
  • Graceful abort on Ctrl-C. SIGINT is handled explicitly, so a run can be
    stopped and its data written out instead of being killed. This also restores
    Ctrl-C when openEMS runs as a Python module, where it previously did nothing.
  • FDTD setup and the CSX structure can be read from and written to XML.
  • The FDTD object can be reset from Python, and an excitation can be enabled and
    disabled.
  • Bundled head and body phantoms in resources/phantoms/, reachable from every
    language interface, installed to share/openEMS/ and shipped inside the
    python wheel. openEMS_resource_path() (Octave) and
    openEMS.utilities.get_resource_path() (Python) return the path of such a
    file, so a tutorial keeps working from wherever it was copied to. The MRI
    tutorials fall back to the phantoms when the IT'IS Virtual Family dataset is
    not installed.
  • New tutorials and examples: Python Horn_Antenna (coaxial pin feed with
    backshort), StripLine2MSL, Dipole_SAR, MRI_Loop_Coil, a rectangular
    resonant cavity example, and a SAR averaging tutorial. Ported from Octave:
    Parallel_Plate_Waveguide, Circ_Waveguide, Conical_Horn_Antenna,
    CylindricalWave_CC and RadarUWBTutorial.
  • Python unit and integration tests, run in CI after each smoke test.
  • Optional oversampling for frequency-domain dumps and probes, to avoid
    the aliasing onto the upper band edge that sampling the DFT accumulation at
    exactly the Nyquist rate causes. A box opts in through CSXCAD's new
    OverSampling property; the default is unchanged, so existing simulations
    and their performance are unaffected.
  • --verbose/-vv now reports the actual TD/FD sampling interval for
    each probe and dump box during SetupProcessing.
  • --exact-endcriteria, which evaluates the energy end-criteria every
    Nyquist period instead of every few seconds of wall-clock time. The run
    then stops at the same timestep regardless of machine speed and load, at
    the cost of performance — mainly useful for engine or code verification.

Changed

  • The MPI engine was removed. It had not compiled for years, as it used
    the C++ MPI bindings that MPI-3 dropped, it had no tests, and several
    extensions never supported it (#260). The multithreaded engine is
    unaffected. WITH_MPI, --engine=MPI, openEMS_MPI.sh, RunOpenEMS_MPI
    and SetupMPI are gone. See Upgrade notes.
  • nf2ff result format. The far field is written as one compound complex
    dataset per frequency, /nf2ff/E_theta/FD/f{n} in (theta, phi) order — the
    format every other frequency-domain dump has used since HDF5 version 0.3 —
    instead of a split f{n}_real/f{n}_imag pair in (phi, theta) order.
    Octave cannot read compound complex datasets, so the Octave/Matlab interface
    keeps the old layout, requested by CalcNF2FF through the new LegacyHDF5
    attribute of the nf2ff XML file. See Upgrade notes.
  • Simulation directory cleanup no longer deletes the directory.
    CleanupSimPath() (Octave/Matlab) and cleanup=True in Python's FDTD.Run()
    now remove only known openEMS output files. Pointing Sim_Path at $HOME, or
    any other directory that matters, no longer destroys its contents. Generic
    *.h5 files are only removed when they carry the openEMS_HDF5_version root
    attribute, so user-supplied HDF5 files such as mode files survive.
  • Command-line argument parsing was rewritten. Options are declared by the
    module that uses them rather than in openems.cpp, which is what makes
    SetLibraryArguments() possible.
  • The Gaussian excitation now ends at exactly zero, and the excitation types
    were renamed more descriptively.
  • Frequency-domain dump files get more readable names, and HDF5 dumps carry more
    metadata attributes.
  • boost/program_options.hpp was removed from the public openems.h.
  • The INVALID lumped-element type was removed, following the same change in
    CSXCAD.
  • Octave/Matlab docstrings were reformatted as Markdown so that the online
    function reference can be generated from them.
  • Python packaging modernised: pyproject.toml, installable with pip,
    dynamic versioning via setuptools_scm, and more robust detection of an
    installed CSXCAD.
  • Internally, the multi-dimensional field arrays were replaced by a new
    ArrayLib, and the engine, operator and their extensions converted to it.
  • Default thread counts (multithreaded engine, nf2ff, SAR) now respect CPU
    affinity and cgroup CPU quotas (Linux only) instead of always using every
    CPU of the host, so a container or systemd unit with a CPU limit no longer
    oversubscribes it.
  • Python CalcNF2FF() reads an existing result file by default
    (read_cached=True), as its docstring already stated and as the Octave
    CalcNF2FF ('Mode', 0) always did. Pass read_cached=False to force
    recalculation.

Fixed

  • DebyeMaterial diverged once sum(eps_delta) approached epsilon, and did
    so silently -- the NaN energy satisfied the end criteria, so the run reported a
    normal finish. Its branch carries no inductance, so integrating it like the
    Drude/Lorentz branch put the update's root on -1. It now integrates the pole's
    capacitor voltage, in its own extension pair; eps_delta is no longer limited,
    and a pole shorter than three timesteps is refused with a warning (#229).
  • Python: a ContinuousStructure handed to SetCSX() is no longer destroyed
    twice. SetCSX() takes ownership, which the binding now states, and
    GetCSX() no longer leaks a fresh structure per call. Requires a CSXCAD
    providing CSObject. See Upgrade notes.
  • Python: GetCSX() returned an empty list after the structure had been read
    with ReadFromXML(), and a wrapper could dangle after Reset().
  • UPML: copy-paste errors in the update coefficients (#221).
  • Tutorial CRLH_LeakyWaveAnt.m: the ground plane was added at the same
    priority as the substrate that spans z=0 as well, so it lost the tie and
    never made it into the operator.
  • Modes higher than 0 in the parallel-plate direction were not excited
    correctly.
  • The mode-match probe coordinates now match the excitation coordinates.
  • nf2ff: m_maxDir was wrong for a radius other than 1.
  • A steady-state engine extension could be freed twice on shutdown, and an
    operator extension that was never initialised could be freed invalidly. An
    extension that finds nothing to do — a conducting sheet without a primitive,
    for example — is now dropped instead of being kept and run empty.
  • Dmax is a linear power quantity and was added to a dB value without
    conversion in the patch-antenna tutorials.
  • Lumped RLC: the auxiliary-differential-equation update had several bugs, and
    C = 0 was not handled.
  • Python: Run() failed on a relative sim_path, and on one containing
    symlinks, with an assertion; both work now.
  • Octave: an oct-file left over from an older Octave version is rebuilt
    instead of failing the run with "failed to load" or, on Windows, "the
    specified module could not be found" (#318).
  • Octave/Matlab: paths containing spaces are quoted for the binary and the log
    file, and HDF5 detection in setup.m was improved and is now tested in CI.
  • Python: SetCustomExcite encoding, and argument parsing with several
    openEMS() instances in one process.
  • The excitation amplitude was ignored by AddCoaxialPort ('ExciteAmp') in
    Octave/Matlab and by the waveguide ports (excite) in Python: any non-zero
    value excited with amplitude 1.
  • Python: a port with the number of an existing port now raises ValueError.
    Both ports wrote their probes to the same files and corrupted them.
    Octave/Matlab already rejected this.
  • Octave: plotRefl died with "vertical dimensions mismatch" instead of
    drawing the Smith chart, because it added the trace after the legend and
    Octave's legend autoupdate could not append it (#172).
  • B-field dumps (DumpType 5/15) were not placed on the dual time/mesh like
    H-field dumps, despite reading the same dual-grid values: values were
    labelled half a cell and half a timestep off.
  • Six of the nine steady-state detection probes sat on the first mesh line of
    their direction (usually a field-free boundary) instead of a quarter/three
    quarters across, due to an integer-division bug.

Build

  • C++11 is now required, and CMake 3.1 or newer.
  • VTK 9 and newer are supported without deprecated names.
  • Windows: builds via vcpkg manifest with MSVC and clang-cl under Visual
    Studio 2022; the openEMS and nf2ff import libraries are installed to
    lib/.
  • Builds on ppc64le.
  • Two knobs for comparing the output of two builds bit by bit, both off the
    default path: debug builds compile with -ffp-contract=off on GCC and
    Clang, and the new ENABLE_FLUSH_TO_ZERO CMake option can be set to OFF
    to keep denormals in the engines.
  • The WITH_MPI CMake option and the --with-MPI option of
    update_openEMS.sh were removed.
  • CI covers Linux, macOS, FreeBSD and Windows, and compiles with warnings
    enabled.

Upgrade notes

  • Rebuild all components together. The CSXCAD CSObject change alters the
    layout of every class deriving from it. The soname is unchanged and will not
    catch a partial rebuild. This release needs a CSXCAD that provides CSObject.
  • A Python script that used a CSXCAD wrapper after its C++ object had been
    destroyed now stops with a RuntimeError instead of reading freed memory.
  • Scripts that relied on cleanup wiping the whole simulation directory now
    keep any file that is not recognised openEMS output. This is deliberate.
  • The bundled phantoms moved from matlab/Tutorials/phantoms/ to
    resources/phantoms/, installed under share/openEMS/.
  • A tool that reads nf2ff result files directly has to handle the compound
    complex datasets described above; nf2ff_results (Python) and ReadNF2FF
    (Matlab) read both formats, ReadNF2FF under Octave only the legacy one.
    Files written by the Octave/Matlab interface are unchanged.
  • Octave/Matlab scripts calling SetupMPI fail, as the function is gone; drop
    the call. RunOpenEMS warns about a Settings.MPI field and runs the
    multithreaded engine instead.