Repository navigation
v0.3.0 — live record, MIDI CC, more modulation
The performance pack.
Live recording of parameter locks
Shift + Play arms it. With the sequencer running, turning a knob writes a lock onto whichever step is playing and arms a trig there. It lives in the engine's parameter path, so the UI, an external MIDI CC and any future web editor all record identically. The play pad turns red while armed.
MIDI CC control
Work was the only module in the family without it. External CC only — Move's own encoders arrive as internal CCs and would fight the UI — with the same duplicate guard Mono uses, because a channel-matched chain slot can deliver one external CC twice.
| CC | Reaches |
|---|---|
| 8–15 / 16–23 | FX 1 / FX 2 parameters A–H |
| 24 / 25 / 26 | FX 1 machine, FX 2 machine, dry/wet |
| 32 / 40 / 48 | FX LFO 1 / 2 / 3 |
| 56–60 | modulation envelope |
| 64 / 65 / 66 | sequencer, fill, live record |
More modulation
A third FX LFO and an AHD modulation envelope that restarts on every firing trig. Resolution order is now base → parameter lock → envelope → LFOs.
Per-step probability
1–100 per step, separate from the trig condition as on Elektron — both gates must pass. Shift + the pattern-page pad selects the mode, then hold a step and turn the jog.
Three bugs the new tests caught first
- Both LFO parameter handlers were hardcoded to
lfo1/lfo2, so everylfo3_*key fell through to an unrelated handler and silently did nothing. - Probability was written to the step string but never to the state blob, so it vanished on preset load.
- The contract fixture had gone stale, which the harness reported as the UI reading a key the engine doesn't serve.
434 engine + 53 UI + 44 site checks. ASan/UBSan clean. Still not verified by ear.