  • Add classic Siemens S7comm through the official Snap7 native library. Independent S7 connection cards support typed DB/M/I/Q bindings, live curves and writes directed to the selected PLC. Types: BOOL, BYTE, SINT, WORD, INT, DWORD, DINT and REAL; BOOL writes preserve neighboring bits.
  • Preview, generated Python source and Nuitka applications share the S7 backend. Windows and macOS packages include the native library and license notices; exported S7 applications carry the library too. Background workers serialize I/O and discard stale results and queued writes after disconnect.
  • Projects using S7 save as UIDP 1.1; ordinary projects remain at 1.0. Older designers cannot open S7 projects. See S7 setup and limits and the paired PLC examples. Use FluentPLC Simulator for local testing. This implements classic absolute-address S7comm; S7CommPlus and optimized/symbolic DB access are outside its scope.
  • Exported application canvases now fit the window as it resizes.
  • Switch feedback supports Modbus registers and configurable ON conditions, including non-zero values, consistently in preview and exported source.
  • Settings and both READMEs link the repository, related HMI tools and the PLC simulator.

简体中文

  • 新增经典西门子 S7comm,基于官方 Snap7 原生库。独立 S7 连接卡片支持 DB/M/I/Q 类型化绑定、实时曲线和定向写入,支持 BOOL、BYTE、SINT、WORD、INT、DWORD、DINT、REAL,BOOL 位写保留邻位。
  • 预览、导出 Python 源码和 Nuitka 应用共用 S7 后端。Windows、macOS 安装包和导出的 S7 应用随附平台原生库及许可说明;后台线程串行处理读写,断开后丢弃旧会话结果和待发写入。
  • S7 工程保存为 UIDP 1.1,其他工程保持 1.0;旧版设计器无法打开 S7 工程。提供配置与范围说明和双 PLC 示例,可搭配 FluentPLC Simulator 本地验证。当前支持经典绝对地址 S7comm,不包含 S7CommPlus、优化 DB 或符号访问。
  • 导出应用画面随窗口大小自动适配。
  • 开关支持 Modbus 寄存器反馈及可配置 ON 判定条件,包括非零为 ON,预览与导出源码保持一致。
  • 设置及中英文 README 增加仓库、相关 HMI 工具和 PLC 模拟器链接。