Debugging: inline values in every POU body for a chosen instance, breakpoints with a halted state, stepping, the call stack and a sorting conveyor debugging guide. Project files are unchanged; the core protocol between the UI and the runtime changes in breaking ways; see Changed.

Added

  • Sorting conveyor debugging guide with a Playwright acceptance walkthrough,
    covering instance and body values, event breakpoints, halted I/O, stepping,
    the call stack and keyboard shortcuts. The counter block body now publishes
    its total through a Value output, preserving the conveyor trace.

  • Statement debugging with Step over, Step into and Step out, keyboard shortcuts
    that preserve control focus across halts, and a selectable call stack showing
    invocation values and in-out actual locations.
    Halted inline values now include unwatched bodies.

  • Editor gutter breakpoints with active/inactive markers, line tracking through
    edits and POU renames, browser autosave, halted statement highlighting and
    Continue. A halt pauses the whole resource and preserves published outputs,
    which panel lamps, numeric displays and I/O image readings keep showing.

  • Inline values inside method and function bodies, with per-instance method calls,
    class instance selection and localized function caller labels. Runtime debugger
    support records every active frame's invocation when debugging is enabled at
    task-run boundaries.

  • Choose the instance shown by inline values in PROGRAM and function block sources,
    with a path/type filter, derived instances, autosaved choices and older-scan labels.

  • Runtime body watches collect function block statement values, including inherited
    bodies and SUPER(), independently for each selected instance.

  • Runtime documentation for internal resumable execution and its repeatable
    scan-time benchmark.

  • ADR 0018 documents the accepted debugging design for Milestone 8: choosing the
    instance whose inline values a body shows, inline values in every body,
    breakpoints, the halted state, stepping and the call stack.

Changed

  • Breaking core protocol changes:
    • Snapshot annotations is an array of { pou, instance, scanCount, lines }
      bodies instead of a record keyed by POU. Annotated function bodies add
      caller: { pou, instance, line }.
    • watchBodies replaces the watched set. Function watches use a null
      instance, and function block and class watches cover all their methods.
      Until the first watchBodies after load, the first instance of every
      PROGRAM is watched.
    • RuntimeState gains HALT. setBreakpoints, continue and debugStep
      are new commands; step remains a single scan.
    • The new halted event reports the underlying operating state, the task and
      the whole call stack, with each frame's values and invocation annotations.
    • Rejected commands include run, step, continue and debugStep, with
      the runtime.halted and runtime.not-halted codes.
    • PROGRAM IR keeps call-local declaration names for halted value reporting.
  • Halted time is excluded from execution times and skipped activations during a
    halt are not overruns. Abandoned task runs leave task telemetry and due times
    unchanged, while their scheduler pass still increments scanCount.

v0.7.0

Choose a tag to compare

@yasukei yasukei released this 26 Oct 10:48
ef93e64

Classes, methods, interfaces and namespaces: function block methods, classes, single inheritance with dynamic binding, interfaces with assignment attempt, references to instances, namespaces and a sorting conveyor example. Contains breaking changes: 20 new reserved words; see Changed.

Added

  • Sorting conveyor reference project combining namespaced classes, inheritance,
    interface-array dispatch, an instance reference and function block methods with
    retained bin totals. Includes sensor buttons, diverter lamps, numeric displays,
    a virtual-clock conformance trace and a browser acceptance test.

  • Namespaces for data types, POUs, classes and interfaces, qualified names and
    USING imports with ordered lexical lookup and ambiguity diagnostics. INTERNAL
    declarations, members and methods respect namespace boundaries. Project files
    preserve exact namespace sources and exchange qualified names; source lists and
    monitor types display qualified names. Structure fields keep their independent
    member names, including names shared with visible types.

  • References to user function block and class instances (REF_TO Motor, REF(inst)
    and REF(THIS)). Dereferences support member access, dynamic method calls and
    function block body calls. Derived references assign to base references; ?=
    casts between instance references and interfaces, clearing mismatches to NULL.
    Instance targets appear as monitor paths and survive project save/reopen.

  • Interfaces with method prototypes, multiple interface inheritance and IMPLEMENTS
    for classes and function blocks. Interface variables bind persistent instances,
    dispatch methods dynamically, compare identities and support assignment attempt
    (?=), which clears the target on mismatch. Monitor targets as paths or NULL;
    add interface sources from a template and preserve them in project files.
    PROGRAM interface in-outs bind exact-type mutable globals through configuration
    connections and share their storage immediately; unbound in-outs are rejected.

  • Single inheritance for function blocks and classes with EXTENDS, dynamic method
    overrides, SUPER method/body calls, ABSTRACT and FINAL. Inherited members retain
    their initializers and retention qualifiers and appear base first in the monitor.
    Project files preserve exact inheritance sources; TC6 elements contain only each
    type's own variables. Faults identify the source declaring the inherited code.

  • Classes with persistent members, methods and THIS, instance arrays and globals,
    access checks and RETAIN/NON_RETAIN restart behavior. Add a class from the source
    list and monitor, write or force its members regardless of access. Project files
    keep exact class sources; other TC6 tools see empty function blocks.

  • ADR 0017 documents the accepted design for methods, classes, inheritance,
    interfaces, references to instances and namespaces for Milestone 7.

  • Function block methods with instance storage, fresh call-local variables,
    formal and positional parameters, return values, access specifiers and THIS.
    Method calls show inline values in PROGRAM bodies; monitor access stays unrestricted.
    Project files preserve exact methods and access in the source extension.
    THIS-qualified member instances and indexed elements support body calls, and
    their bounds faults identify the member array in the instance path.

Changed

  • INTERFACE, END_INTERFACE, IMPLEMENTS, CLASS, END_CLASS, EXTENDS, OVERRIDE, SUPER,
    ABSTRACT, FINAL, METHOD, END_METHOD, THIS, PUBLIC, PROTECTED, PRIVATE, INTERNAL,
    NAMESPACE, END_NAMESPACE and USING are now reserved. Texts in 0.6.0 project files
    that use them as names open as editable drafts, from the preserved source text or,
    when it is absent, from text generated from the standard elements. Autosave keeps
    drafts; rename the identifiers before running or exporting the project.

v0.6.0

Choose a tag to compare

@yasukei yasukei released this 25 Oct 09:23
6698624

Configurations, tasks and global variables: configuration sources with several program instances, cyclic and event tasks, global variables, PROGRAM parameters, byte, word and memory addresses, numeric panel parts, and retentive variables with warm restart. Contains a breaking change to monitor paths; see Changed.

Added

  • Tank station reference project combining two parameterized tank controllers,
    fast control and slower statistics tasks, an alarm acknowledge event task,
    shared globals and a high-level constant, %M pump flags, numeric panel
    controls and retentive run-time counters with virtual-clock and browser tests.

  • RETAIN and NON_RETAIN declarations, warm restart and fault acknowledgement into
    STOP. Retained scalars and counter/edge/bistable state survive browser reloads;
    timers and references reset. Browser storage saves complete retained sets at most
    once per second during execution and after state-changing commands, reports
    restore mismatches by path until the next load or reset, and warns on storage
    failures. PLCopen XML preserves retention qualifiers on POU and global variable lists.

  • Numeric operator panel inputs and displays for byte, word, double-word and
    long-word I/O, with type validation, exact 64-bit integer entry, optional input
    bounds and sliders, and monitor formatting for outputs and invalid real values.
    The panel editor configures their labels, types and addresses; numeric layouts
    save as panel extension version 2 while legacy layouts keep their version rules.
    New parts default to free addresses that avoid existing bit and numeric bindings.

  • Typed direct addresses in 64-byte input/output areas and a 1,024-byte memory
    area, with shared overlapping views, little-endian byte/word/double-word/long-word
    access, and warnings for overlapping output writers. Invalid REAL/LREAL patterns
    fault on program reads and display safely with raw bits in the monitor. The I/O
    image shows used addresses in their declared types. Panel bit controls support
    every I/O byte; projects save the address-based panel extension version 2 only
    when needed and retain version 1 compatibility for byte-zero layouts. Imported
    panel addresses are normalized so address selection and automatic bindings stay
    consistent.

  • Up to 16 cyclic and rising-edge event tasks with non-preemptive priority
    scheduling, independent intervals, missed-activation overrun counts and task-level
    I/O boundaries. Single scans cover every cyclic task and rising event input;
    faults stop the whole resource and identify the task. The status area displays
    per-task run counts, last/maximum execution times and overruns in English/Japanese.
    Inline values stay visible between runs of slower and event tasks and refresh
    when their program's first instance runs again.

  • PROGRAM inputs and outputs with per-instance configuration connections to
    constants, globals and direct addresses. Values copy around each
    instance with forces restored at every boundary. Connected inputs reject monitor
    writes and accept forces; unconnected inputs keep their values. PLCopen XML
    preserves program interfaces and exact connection source text. Direct addresses
    connect in the configuration; AT on PROGRAM input/output declarations is rejected.
    Connection lists reject empty parentheses and trailing commas.

  • Configuration and resource global variables and constants, imported by PROGRAMs
    and function blocks through VAR_EXTERNAL. Globals share storage across instances,
    support derived types, references, FBs and direct addresses, and appear in
    a Globals monitor group with write and force controls. PLCopen XML preserves global
    and external declarations and CONSTANT attributes; imported constants work in
    array bounds and CASE labels. Invalid global declarations report configuration
    errors without cascading missing-global messages in importing POUs.

  • Configuration source editing in the web source list, with one cyclic-task
    template containing every PROGRAM, header-based renaming, diagnostic navigation
    and confirmed deletion back to implicit mode. Browser autosave preserves
    configuration drafts and selection and migrates 0.5.0 records unchanged.

  • PLCopen XML save/open for exact configuration sources, multiple tasks and program
    instances, and event task inputs. Imports without preserved text reconstruct
    configuration source when the implicit model cannot represent the structure.
    The web app compiles imported configurations, keeps them through autosave and
    hides the implicit cycle selector while a configuration source is present.

  • Configuration source compilation with one resource and up to 64 independent
    program instances sharing their PROGRAM bodies. Configured task intervals drive
    runtime execution; explicit configurations reject cycle commands.
    Existing projects use an implicit configuration and keep their cycle control.

  • ADR 0016 documents the accepted design for configurations, tasks and scheduling,
    global variables, program parameters, byte, word and memory addresses, retentive
    variables and warm restart for Milestone 6.

Changed

  • Monitor and reference paths are now qualified by program instance, including
    mainInstance.LAMP in existing projects. The monitor groups instances and shows
    relative paths within each group. Inline values identify their instance and
    annotations are keyed by POU and line, using the first instance of each PROGRAM.

v0.5.0

Choose a tag to compare

@yasukei yasukei released this 24 Oct 06:33
70598e0

Derived data types and strings: enumerations, subranges, arrays, structures, strings and references, with PLCopen XML exchange and monitor support for composite variables. Contains breaking changes to accepted Structured Text; see Changed.

Added

  • Batch mixer reference project combines an enumerated CASE state machine, three
    initialized recipe structures in an array, a latched recipe reference, TON step
    timers and CONCAT status messages. Includes panel controls and lamps,
    virtual-clock traces for every recipe and STOP/restart, and a browser test for
    operation, monitor values and exact text preservation on save/reopen.

  • References (REF_TO, REF, ^, NULL) to persistent variables, elements and
    members, including reference parameters/results, MOVE/SEL/MUX selection,
    dereferenced in-out arguments and recursive structures.
    Reference targets match exactly; NULL dereferences fault with POU/instance
    diagnostics. Monitoring displays target paths or NULL without write/force
    controls, and PLCopen XML exchanges references as pointer types.

  • Arrays and structures as copied input/output parameters, in-out aliases and whole
    function results. Open ARRAY[*] in-outs accept caller arrays with different
    bounds, with DINT LOWER_BOUND/UPPER_BOUND queries. Element/member aliases
    preserve caller storage, string capacities and force behavior; PLCopen XML
    round-trips aggregate interfaces and open dimensions.

  • Diagnostics name the actual block type when a scalar instance is indexed, and
    explain unsupported named/nested function block arrays once per declaration in
    English and Japanese.

  • Arrays of standard and user function block instances in PROGRAM and function
    block VAR sections, with indexed calls and public port access, independent
    persistent state, shared timer/counter variant selection and cold reset of
    every instance tree. The monitor groups element paths and supports member
    writes/forces; PLCopen XML preserves arrays with derived block base types.

  • Structure declarations report unsupported function block member types on the
    type name, with an explanation of the restriction in English and Japanese.

  • Named structures with member defaults, nested array/member access, partial
    initializers, and whole-structure assignment/MOVE/SEL/MUX. The monitor expands
    structures and arrays of structures and supports scalar member writes and
    forces. PLCopen XML preserves nested structure declarations and initial values.

  • Array diagnostics distinguish non-array access, index counts, non-integer
    indices and missing initializer lists, with the relevant types and counts.

  • Arrays with constant DINT bounds, up to three dimensions and 10,000 scalar
    leaves, nested arrays, repeated initializers, checked indexing, element bit
    access and whole-array assignment/MOVE/SEL/MUX. Array elements support strings,
    enumerations and subranges. The monitor expands arrays and writes/forces
    individual elements; snapshots include watched or forced elements. Editor
    hovers show array types, and PLCopen XML preserves array types and initial values.

  • Standard STRING/WSTRING functions LEN, LEFT, RIGHT, MID, extensible CONCAT,
    INSERT, DELETE, REPLACE and FIND, with checked positions, clamped lengths and
    results up to 1,024 code units. CHAR/WCHAR inputs widen to their string types.
    Elementary values convert to and from text using
    the monitor format and literal syntax; character/code-unit conversions and
    overloaded TO_ forms are supported. Invalid conversions fault without wrapping.

  • STRING, STRING[n], WSTRING, WSTRING[n], CHAR and WCHAR variables, aliases,
    constants and POU parameters/results, with quoted literals and dollar escapes.
    Comparisons, selection and ordering functions support character data; dynamic
    string stores truncate to capacity. The monitor displays quoted text and validates
    quoted writes and forces, inline values preserve string types, the editor
    highlights literals, and PLCopen XML preserves capacities and character types.

  • Data types appear before POUs in the web editor, with templates, text-based
    renaming, confirmed deletion and diagnostic navigation. Project-wide Run,
    type highlighting and variable hovers include declared types; autosave keeps
    unfinished type drafts and restores older POU autosaves.

  • PLCopen XML saves and opens ordered data type sources, including enumerations,
    named and inline integer subranges, elementary and derived aliases, and their
    initial values. Source extensions preserve exact text; imports without them
    rebuild equivalent TYPE declarations. The web app retains imported types for
    compilation, monitoring, browser autosave and project save/open.

  • Compiler data type sources with elementary aliases, enumerations and named or
    inline integer subranges (ADR 0015). Enumerations support contextual literals,
    CASE, selection functions and scalar POU parameters/results; subrange stores
    fault outside their limits. Monitor helpers format enum names and validate
    writes and forces.

  • ADR 0015 documents the accepted design for data type declarations, enumerations,
    subranges, arrays, structures, strings and references for Milestone 5.

Changed

  • Breaking: CHAR, WCHAR, REF_TO, REF and NULL are now reserved keywords (ADR 0015).
    The standard namespace also reserves LEN, LEFT, RIGHT, MID, CONCAT, INSERT,
    DELETE, REPLACE, FIND, LOWER_BOUND, UPPER_BOUND, TO_STRING, TO_WSTRING, TO_CHAR, TO_WCHAR and the
    ADR 0015 character/string conversion names, including <type>_TO_STRING,
    <type>_TO_WSTRING, STRING_TO_<type> and WSTRING_TO_<type>. Existing identifiers
    using these names must be renamed. STRING and WSTRING remain reserved; string
    functions/conversions and references are available.

Fixed

  • Compiler diagnostics name the actual standard or user function block type in
    structure array members, identify containment and alias cycles without
    cascading unknown-type errors, and explain the restriction on subrange FOR
    control variables in English and Japanese.

v0.4.0

Choose a tag to compare

@yasukei yasukei released this 23 Oct 01:05
85a7482

User-defined functions and function blocks in projects with several POUs, with VAR_IN_OUT, VAR_TEMP, CONSTANT and timers and counters that adapt to their preset type. Contains breaking changes to accepted Structured Text; see Changed.

Added

  • Motor starters example with two independent instances of a user-defined
    function block, nested TON start delays, a shared interlock function,
    START/STOP and overload controls, status lamps and virtual-time traces.

  • Overloaded TON, TOF, TP, CTU, CTD and CTUD select timer/counter
    variants from typed PT/PV bindings in their declaring POU, including user
    function blocks. Monitor rows and editor hovers show resolved types; PLCopen XML
    preserves the declared names and selects again on open. Failed selection reports
    the incompatible preset types without misleading default-variant narrowing errors.

  • VAR CONSTANT in programs, functions and function blocks: typed compile-time
    values with default initializers, earlier-constant references and wrapping
    arithmetic. Constants work in initializers, CASE labels, bit indices and FOR
    bounds/step, with no runtime storage or monitor entries; writes are rejected.

  • PLCopen XML constant sections, including canonical imports and initializer
    validation in the context of earlier constants in each POU.

  • VAR_IN_OUT parameters on functions and function blocks, passed as exact-type
    caller variable aliases on every formal call. Writes are visible immediately,
    aliases can be passed on, and monitoring and forces use the actual variable's ID.
    In-out declaration initializers are rejected because values belong to the caller.

  • Save and open in-out sections as PLCopen XML inOutVars, including canonical
    imports without preserved source.

  • User-defined function blocks with independent persistent instances, nested user
    and standard blocks, per-call VAR_TEMP, and PROGRAM VAR_TEMP per scan.

  • Named => output bindings on user and standard function block calls, with
    implicit assignment widening.

  • Dotted monitor members with writes and forces, instance paths in runtime faults,
    and PROGRAM inline output values for user function block calls.

  • Add function blocks from the POU list and preserve block POUs, nested instances
    and temporary sections in PLCopen XML.

  • Manage project POUs beside the ST editor: add and delete functions, switch texts,
    navigate project-wide diagnostics, and preserve all drafts in browser autosave
    with migration from 0.3.0 single-program work.

  • Save and open an ordered collection of programs and functions in PLCopen TC6
    XML, preserving each POU's exact editor text, input/output declarations and
    optional function result type. Existing 0.3.0 project files remain readable.

  • Save and reopen parseable projects with semantic errors, including missing
    functions, duplicate names and zero or several programs. Initializer range
    errors still block exchange. The web editor retains the other imported POUs.

  • Compile a project from several POU sources with user-defined functions, formal
    input defaults, output bindings, nested calls and fresh local storage per call.
    The web editor shows one POU at a time.

  • Compiler and runtime diagnostics identify the source POU; the editor displays
    that name alongside the location.

  • ADR 0014 documents the accepted design for user-defined POUs, calls, instance
    memory, project exchange and monitoring for Milestone 4.

Changed

  • POU names share a case-insensitive namespace with standard functions, function
    blocks and elementary types. Variables cannot reuse a POU name, including the
    PROGRAM name. PROGRAM parameters and function recursion are compile errors.

Fixed

  • Saving imported PLCopen projects stamps the company, product name and version
    together as benchtop-plc's writer identity and removes imported company URLs and
    product release strings. Creation time, content description and the content
    header are preserved. A foreign product name or company URL is no longer paired
    with benchtop-plc's version.

v0.3.0

Choose a tag to compare

@yasukei yasukei released this 22 Oct 09:52
ceb3807

All elementary data types except strings, with the standard's conversion and literal rules and the standard functions and function blocks for them. Contains breaking changes to accepted Structured Text; see Changed.

Changed

  • Conversion portability warnings now name the resolved function and explain the
    rightmost-bit or bit-pattern behavior in English and Japanese, including overloaded
    TO_ calls. Warnings allow programs to load and run.

  • New standard function names (including SUB, EQ and LT) are reserved against
    variable declarations; existing programs using those names must rename them.

  • Breaking: AND, &, OR, XOR and NOT now accept BOOL and bit strings only;
    integer operands require an explicit conversion to a bit-string type.

  • Runtime initial values and write/force commands reject out-of-range values for
    every supported type. Project imports and exports reject out-of-range initializers.

  • TIME is now signed 32-bit milliseconds. Out-of-range duration literals, IR initial
    values and write/force values are rejected. TIME arithmetic wraps modulo 2^32;
    real scaling rounds the exact result once to milliseconds, nearest with ties to even.

  • Narrowing assignments and typed inputs now require explicit conversions. Numeric
    operators and generic functions use ADR 0013 common types; REAL + LREAL is LREAL.

  • Untyped constants are evaluated exactly and checked against the type supplied by
    their position. Out-of-range constants are errors instead of silently wrapping.
    Real constants round directly to binary32 or binary64, once. Decimal scales
    outside ±10,000 are rejected before allocation to keep compilation responsive.

  • Octal literals (8#) are rejected.

Added

  • Running light example project with START/STOP, a direction selector, eight LEDs,
    BYTE rotations and bit access, a UDINT rotation counter and virtual-time traces.

  • Standard SR/RS bistables, CTUD, typed CTU/CTD/CTUD counters for INT, DINT,
    LINT, UDINT and ULINT, and TON/TOF/TP_TIME and _LTIME timers. Counters saturate
    at type limits; long timers use nanoseconds from the injected clock, subject
    to host clock resolution. All new blocks round trip through PLCopen XML and
    expose typed monitor ports. Their names are reserved against declarations.

  • Standard time/date arithmetic and long forms, calendar constructors, component
    splitting and DAY_OF_WEEK. Function calls support statements and SPLIT output
    assignments with =>; INT outputs widen implicitly and the result is BOOL.
    Missing formal inputs report one arity error; unsupported FB call syntax reports
    that named := inputs are required.

  • Standard numeric and arithmetic functions, ** exponentiation, width-aware
    shifts/rotates, bitwise calls, MOVE/MUX and comparison functions, including
    exact 64-bit arithmetic. Selection functions now cover all compatible elementary
    types, including BOOL and calendar values. Typed TRUNC and packed BCD conversion
    families wrap integer results and fault on invalid input.

  • DATE, TOD, DT, LDATE, LTOD and LDT throughout the compiler, runtime, variable
    monitor and PLCopen XML, with Gregorian literals (including unpadded fields and
    underscore separators), calendar conversions, exact
    nanosecond long values, chronological comparisons and duration arithmetic.
    Times of day wrap within one day; out-of-range dates fault. Calendar defaults
    use the Unix epoch or midnight.

  • LINT, ULINT, LWORD and LTIME throughout the compiler, runtime, variable monitor
    and PLCopen XML, with exact 64-bit arithmetic and JSON-safe decimal strings.
    LTIME supports nanosecond literals and exact real scaling; LWORD supports all
    64 bits. Numeric, bit-pattern and duration conversions include overloaded TO_
    forms and LREAL ↔ LWORD reinterpretation. DINT + UDINT now has common type LINT.

  • SINT, USINT, UDINT, BYTE, WORD and DWORD throughout the compiler, runtime,
    PLCopen XML and variable monitor, with typed literals, width-based wrapping,
    unsigned 32-bit values and full-width hexadecimal display for bit strings.

  • Bit-string operators, comparisons and readable/writable bit access (w.15).

  • Numeric, bit-pattern and TIME conversion families for the new types, including
    overloaded TO_ forms and REAL ↔ DWORD IEEE binary32 reinterpretation.
    Portability warnings identify conversions whose vendor semantics may differ.

  • Monitor writes and forces for the new types; bit strings accept decimal,
    hexadecimal (16#) and binary (2#) input.

  • Typed literals for BOOL, INT, DINT, UINT, REAL and LREAL, including based integers,
    with editor highlighting; integer constants 0/1 in BOOL positions and BOOL ordering.

  • Explicit and overloaded conversions across the supported numeric types,
    BOOL to integer conversions, and TIME ↔ integer extensions in milliseconds.

  • ADR 0012 documents the planned elementary data types, ranges, defaults and
    overflow rules for Milestone 3.

  • ADR 0013 documents the planned implicit and explicit conversions, literal
    typing and operators for Milestone 3.

  • An IEC 61131-3 compliance table documents current language support, limits and
    implementation-dependent choices.

v0.2.0

Choose a tag to compare

@yasukei yasukei released this 20 Oct 09:59
515b506

Release process, workflow security checks, automated dependency updates and a public demo. No language changes.

Added

Fixed

  • Direct addresses such as %IX0.0 are now highlighted in the editor, and the
    browser console no longer warns about an unknown highlighting tag.
  • Saved PLCopen projects now identify the writing app's package version, including
    when resaving older projects, while preserving unrelated project metadata.

v0.1.0

Choose a tag to compare

@yasukei yasukei released this 18 Oct 14:42
969fc65

First release: the single-file HTML prototype rebuilt as a tested monorepo.

Added

  • Structured Text compiler with diagnostics: one PROGRAM, the types BOOL,
    INT, DINT, UINT, REAL, LREAL and TIME, and the statements IF,
    CASE, FOR, WHILE, REPEAT, EXIT and RETURN.
  • Scan-cycle runtime with the operating states STOP, RUN and FAULT and an
    emergency-stop overlay.
  • Standard function blocks TON, TOF, TP, R_TRIG, F_TRIG, CTU and
    CTD, and the standard functions ABS, MIN, MAX, LIMIT, SEL and basic
    type conversions.
  • Debugging: force and write variables, single scan, and live values shown next
    to the source.
  • Operator panel with LEDs, push buttons, selector switches and an emergency
    stop on the bits %IX0.0–%IX0.7 and %QX0.0–%QX0.7, plus an I/O image and
    a variable monitor.
  • Open and save projects as PLCopen XML (TC6 v2.01).
  • English and Japanese user interface.
  • Work is saved automatically in the browser, and the theme follows the system
    setting unless you choose Light or Dark.
  • The app opens with the blink example and its panel.