Skip to content

visuals modulation 22 ellipse

Aisjam edited this page Nov 15, 2026 · 1 revision

ELLIPSE

Home · Section index

Working manual · 0.0.1-alpha · source snapshot 16 November 2026

Function 16 hex · 22 decimal · Vector2. Elliptical motion. Signed speed; aspect ratio. Middle aspect is circular.

Configure the function

  1. In VIS, open Y MATRIX and select PC1 for slot C or PD1 for slot D.
  2. Open the function picker from the selector and choose ELLIPSE.
  3. Edit X at PC2/PD2 and Y at PC3/PD3 by holding A with directions, then release A to apply; B cancels the numeric edit.
  4. Choose a destination at PC4/PD4 and check source/lane, route enable, depth, neutral offset and clamps in the source/routing panel.

Inputs and units

Input Panel cell Curve Physical range
Speed PC2 / PD2 BN -10 to 10
Aspect Ratio PC3 / PD3 UN 0.125 to 8

Every modern input retains all 256 raw codes 00–FF. UL is unipolar linear, BL bipolar linear, UN unipolar nonlinear, BN bipolar nonlinear and STEP a discrete selector. Nonlinear mappings are piecewise rather than a single exponential knob curve. Bipolar 7F/80 is exactly neutral. This function has an explicit middle anchor of 1 for its aspect/exponent control. See curve tables before deriving a physical value from a byte.

Routing and a first use

This produces multiple components. Choose a compatible grouped spatial destination such as Position XY/XYZ, or press X on the destination to select AUTO/X/Y/Z where the function has that dimension. A grouped destination uses the vector; a single destination needs the intended component.

Start with a modest route depth and a visible object. Set the two controls within their ranges, then compare components separately. Signed rates reverse direction through neutral; continuous position/rotation destinations wrap, while ordinary normalised controls clamp. Vector and Math time uses musical beats during playback or elapsed seconds for Internal/stopped preview.

Saving and legacy presets

Function, source and routing settings are authored VIS state. Runtime motion does not overwrite their base values. An OLD mapping retains its old range/gain until explicitly converted with X on an OLD X/Y cell or by choosing a different function. That conversion can change the image; ordinary Save does not silently perform it.

What should be here

Documentation still to add
A short animation with input/output values visible, an exact useful route preset and a verified clock/reset example.

Evidence and verification

Repository sources used for this page:

  • src/core/visualiser/Modulation/VISModulation.hpp
  • src/core/input/VISPicker.hpp
  • src/core/visualiser/Modulation/VISParameters.hpp
  • docs/vis-value-curves.md

This is a documentation/source review, not a new runtime or hardware test. Physical response, screenshots and listening examples still need verification on a recorded build.

Clone this wiki locally