Repository navigation
visuals modulation 49 slide
Working manual · 0.0.1-alpha · source snapshot 16 November 2026
Function 31 hex · 49 decimal · Transitions. Moves the finished layer off screen. X: left/right/up/down. Y: visible 00 to hidden FF.
- In VIS, open Y MATRIX and select PC1 for slot C or PD1 for slot D.
- Open the function picker from the selector and choose SLIDE.
- Edit X at PC2/PD2 and Y at PC3/PD3 by holding A with directions, then release A to apply; B cancels the numeric edit.
- The destination reads LAYER OUTPUT. Keep the route enabled and edit Y to progress the transition; it does not advance automatically.
| Input | Panel cell | Curve | Physical range |
|---|---|---|---|
| Direction | PC2 / PD2 | STEP | 0 to 3 |
| Progress | PC3 / PD3 | UL | 0 to 1 |
Every modern input retains all 256 raw codes 00–FF. UL is unipolar linear, BL bipolar linear, UN unipolar nonlinear, BN bipolar nonlinear and STEP a discrete selector. Nonlinear mappings are piecewise rather than a single exponential knob curve. Bipolar 7F/80 is exactly neutral. See curve tables before deriving a physical value from a byte.
Y=00 is fully visible and Y=FF is fully hidden, including cached artwork and feedback. X changes the transition shape/direction described above. Progress is linear input and is not attenuated by the old depth/gain controls. Switching between transition types preserves progress; switching from a regular modulator begins at visible 00.
Start at Y=00, move to 80, then FF and compare the result. To animate automatically, put a Math function in the other slot, route it to this slot’s Progress destination, leave the transition Y base at 00 and use route depth 1 for full-range movement. C and D transitions apply in that order. Other visual lanes and the HUD remain unaffected.
Function, source and routing settings are authored VIS state. Runtime motion does not overwrite their base values. An OLD mapping retains its old range/gain until explicitly converted with X on an OLD X/Y cell or by choosing a different function. That conversion can change the image; ordinary Save does not silently perform it.
| Documentation still to add |
|---|
| A short animation with input/output values visible, an exact useful route preset and a verified clock/reset example. |
Repository sources used for this page:
src/core/visualiser/Modulation/VISModulation.hppsrc/core/input/VISPicker.hppsrc/core/visualiser/Modulation/VISParameters.hppdocs/vis-value-curves.md
This is a documentation/source review, not a new runtime or hardware test. Physical response, screenshots and listening examples still need verification on a recorded build.