Skip to content

Release 9.6.0

andy edited this page Nov 22, 2026 · 8 revisions

Last updated: 2026-11-22 10:20 CET. What has to be true before 9.6.0 is tagged. 9.6.0 completes ECCE as one program on Windows and macOS (#983, #1069) and the built-in broker for local sessions (#1007).

Feature freeze

Until 9.6.0 is tagged, main takes only work on #983/#1069/#1007 and bug fixes. New features (LAMMPS, coarse-grained models, Perl to Python, ECCE-MD, ECCE-PW) wait until after the release.

Tag criteria

  1. No open crash or data-loss bug.
  2. The teaching example set passes.
  3. Every workflow script below passes without a new finding on Linux, Windows and macOS.
  4. One full round of the scripts with no new serious finding.

Blockers

Issue What State
#1239 Organizer crash in an open menu likely cause fixed on main; watch for recurrence
#1249 First Viewer after an upgrade stays at 'Starting the Viewer…' branch, not reproduced
#1248 Undo of a solvent deletion does not bring the water back works headlessly on main; hand check
#1237 Organizer details pane empty or very slow in progress
#1245, #1246 A bare structure opens the Diffraction pane, which starts a slow calculation with no progress or Cancel in progress
#1244 Docking set-up on a crystal structure (ligand choice, Add Hydrogen) branch, building
#1124 ECCE-QM optimisation never converges for some structures (net translation in the gradient) in progress
#933 Windows 11 Smart App Control blocks ECCE needs at least documented steps

Not reproduced since recent fixes, blockers again if they recur: #1122 (crash in tab mode, checked on macOS with the reported steps), #780 (crash after an ssh timeout).

Not blocking (fixed when time allows, may ship in 9.6.x): #1236 #1238 #1241 #1243 #1142 #1129 #1128 #1127 #1089 #995 #970 #965 #930 #806 #506.

Branches to finish

wip/1069-platform, wip/1069-win-layout, wip/viewer-stuck(-2), wip/mo-clicks, wip/tab-flash, wip/1236-overlay, wip/1244-docking, wip/1247-undo-focus: each is merged after its test run, or closed.

Workflow scripts

Run the same steps each round, from a fresh start of ecce. Note what fails and at which step.

W1. A first calculation (ECCE-QM water)

  1. Organizer: open the Getting Started examples and copy the ECCE-QM water calculation to a new project.
  2. Open it in the Builder; check the structure; close the Builder.
  3. Calculation Editor: check theory and run type; Save.
  4. Launch on this computer.
  5. Watch the run state go from submitted to running to completed.
  6. Open the Viewer: geometry, energy, orbitals, vibrations.
  7. Quit ECCE; start it again; the calculation is still there and completed.

W2. A structure from a file, then docking

  1. Open a PDB file from the file manager (Open With > ECCE), e.g. 181L.
  2. Remove water and additives (Edit > Select…, Delete); undo once; redo the delete.
  3. Build > Add Hydrogen.
  4. Edit > Select Ligand: choose the ligand from the list.
  5. Save as a Vina docking calculation; Runtype Details: the ligand is preselected.
  6. Launch; open the poses when it has finished.

W3. A periodic calculation (Quantum ESPRESSO)

  1. New calculation; Builder: Periodic Builder, build diamond (or import a CIF).
  2. Replicate 2×2×2 with Centre lattice; check all atoms are in the cell; back to 1×1×1.
  3. Calculation Editor: Quantum ESPRESSO SCF; Save; Launch.
  4. Viewer: energy, cell, any band or DOS data.

W4. Looking at finished calculations

  1. Organizer: click through ten finished calculations of different codes.
  2. Each details pane fills within a second and shows the structure on the Builder button.
  3. Open three in the Viewer; use the Properties list and two panels each.
  4. Select an atom; its details appear in the view.
  5. Close the Viewers.

W5. Tabs, windows and Quit

  1. Open a Builder, a Calculation Editor and two Viewers as tabs.
  2. Move one tab to its own window and back.
  3. Use the Window menu while moving the mouse over its items.
  4. Close each tab with one click.
  5. Quit: ECCE ends within a few seconds; no ECCE processes are left (pgrep -a ecce).

W6. A job on a cluster over SSH

  1. Register (or open) a cluster machine; log in.
  2. Launch a short calculation there.
  3. Organizer: the SSH folder opens in a few seconds and shows the run.
  4. Disconnect; reconnect; the state is correct.
  5. Fetch the output when it has finished; open the Viewer.

Clone this wiki locally