Repository navigation
(5) Settings (FaraRotation_Settings.h)
Your default Callsign and Grid.
They can be modified from the Config page and saved in EEPROM.
Make sure not to exceed the maximum length otherwise strange things can happen:
#define CALLSIGN " N5NHJ " // ATTENTION!: Max 9 characters
#define GRID "EM13pc" // ATTENTION: Max 6 characters
#define UTCDIFF 0 // Time Difference between Real Time Clock and GMT
Serial/Control port definition if you need to look at debug messages:
#define CONTROL_PORT_MAPPED_TO &Serial
#define CONTROL_PORT_BAUD_RATE 115200
Nextion Serial Port Settings. For the Mega 2560 follow this reference table:
| Serial | pins |
|---|---|
| 0 | 0 (RX) and 1 (TX) |
| 1 | 19 (RX) and 18 (TX) |
| 2 | 17 (RX) and 16 (TX) |
| 3 | 15 (RX) and 14 (TX) |
#define NEXTION_PORT_MAPPED_TO &Serial3
#define NEXTION_PORT_BAUD_RATE 115200
Enabling and Disabling PROGRAM FEATURES: (You want to activate only one of the following two definitions)
#define DIGITAL_OUTPUT Uncomment this if you want to use ON/OFF like motor drivers (Relays..).
#define PWM_OUTPUT Uncomment this if you want to use PWM-capable motor drivers.
#define SLOW_START_STOP Uncomment this if you want to activate the slow start/stop feature over PWM-capable pins. Only works if PWM_OUTPUT is enabled.
#define PTT_AUTOMATION Uncomment this if you want to activate the PTT automation feature.
#define EXTERNAL_REFERENCE Uncomment this if you need a more accurate and stable reading of the potentiometers. Provide the 5V reference to the VREF pin.
#define ONE_ANTENNA (NOT FULLY IMPLEMENTED YET) Uncomment this to have only the RX (or single) antenna/array controls on the Nextion GUI.
PWM AND SLOW START/STOP CONFIGURATION
#define PWM_SPEED 255 Max speed for a PWM controlled drive (0 to 255)
#define SLOW_START_STOP_MIN 50 Min speed for the slow start/stop feature
#define SLOW_START_STOP_DELAY 200 Duration of the ramp-up, slow-down loop to control the slow start/stop feature
#define SLOW_START_STOP_STEPS 50 Increments or decrements of the speed for each loop
#define SLOW_START_STOP_PROXIMITY 3 Distance from the target for starting the slow start/stop loop (Degrees)
TIMING CONFIGURATION FOR MAJOR ACTIONS AND LOOPS
#define POTS_READING_RATE 100 // Potentiometer reading loop timing (millisecs) Nextion timer refresh is set to 100ms
#define INFO_SENDING_RATE 1000 // Info broadcasting timing (millisecs)
#define STATUS_SENDING_RATE 250 // Info broadcasting timing (millisecs)
#define RTC_READING_RATE 1000 // RTC reading timing (millisecs)
#define PTT_CHECKING_RATE 200 // RTC reading timing (millisecs)
#define ACTION_LOOP_RATE 50 // Reaction loop timing (millisecs)
#define CONTROL_PORT_READ_RATE 500 // NOT IN USE
#define NEXTION_PORT_READ_RATE 250 // Command loop timing (millisecs)