Skip to content

MPC 600 S, LA Version 1.5

Choose a tag to compare

@LA-2500 LA-2500 released this 17 Nov 23:34
· 6 commits to main since this release

Fix: the screen jumping while turning knobs or using the data wheel. Turning K1–K3, the slider or the main volume, or turning or pushing the data wheel, presses on the panel, and the pads near them could send light hits of their own. On an editing page such a hit selected another pad, so the page jumped to its sample. (1.4 caught these only right after a real pad hit.)

  • For 300 ms after a knob, slider or wheel movement, and while the wheel is held down, pad hits lighter than velocity 48 are ignored. Firm presses still play.
  • The 1.4 rule for neighbouring pads stays.
  • If pads still play by themselves, raise Pad Thresh in Additional Settings.

Save/Load:

  • SHIFT + Pad 16 opens Save/Load on the Mode and Type used last: after loading an MPC 2500 PROJECT it opens on LOAD, MPC 2500 PROJECT. The first time after power-on, SAVE PROJECT.
  • LOAD has two pages: first Mode, Type, Into and Clear all, then B3 opens the files, which work like Load Files: the wheel moves the bar, pushing the wheel (or B3) opens a folder or loads the item, B1 goes up a folder.
  • On the files page, B2 renames; Delete is SHIFT + B2, so it can't be pressed by accident. It still asks first.
  • LOAD: new Clear all field (NO / YES). With YES, Load asks "Clear all, then load?", empties every program, sound, sequence and song (settings stay), then loads. It goes back to NO after each use.

Install: extract MPC-600-S-OS-v1.5.zip and replace the autorun folder on the card. Your saved work, in MPC600S, is untouched.