Notifications
You must be signed in to change notification settings - Fork 12
Inverter Configuration
Matthias Strubel edited this page Dec 2, 2025
·
7 revisions
This is the uppler limit to charge the battery from grid. Value is WATT. This value should not be above the limit of your inverter.
Default:
max_grid_charge_rate: 5000
This limits the used amount of PV to charge the battery. Value is WATT.
With adding # in front of the value, this limit is not set and will push all PV into the battery.
Default:
#max_pv_charge_rate: 3000 (Disabled)
This enables the MQTT inverter driver, which allows integration with any battery/inverter system via MQTT topics. This is a generic bridge that works with any external system that can publish battery status and receive control commands over MQTT.
For detailed documentation, see MQTT Inverter.
inverter:
type: mqtt
capacity: 10000 # Battery capacity in Wh (required)
min_soc: 5 # Minimum SoC % (default: 5)
max_soc: 100 # Maximum SoC % (default: 100)
max_grid_charge_rate: 5000 # Maximum charge rate in W (required)
cache_ttl: 120 # Cache TTL for SOC values in seconds (default: 120)Key Features:
- Generic MQTT-based integration for any inverter
- Uses batcontrol's shared MQTT connection
- Supports Home Assistant auto-discovery
- Real-time status updates and command control
- No vendor-specific protocols required
This enables the Fronius GEN24 inverter.
inverter:
type: fronius_gen24 #currently only fronius_gen24 supported
address: 192.168.0.XX # the local IP of your inverter. needs to be reachable from the machine that runs batcontrol
user: customer #customer or technician lowercase only!!
password: YOUR-PASSWORD #
max_grid_charge_rate: 5000 # Watt
fronius_inverter_id: '1' # Optional: ID of the inverter in Fronius API (default: '1') (ab 0.5.6)
fronius_controller_id: '0' # Optional: ID of the controller in Fronius API (default: '0') (ab 0.5.6)- fronius_inverter_id: Optional parameter to specify the inverter ID in the Fronius API. Default is '1'.
- fronius_controller_id: Optional parameter to specify the controller ID in the Fronius API. Default is '0'.
This option is for testing purposes only
*** Sample needs to be added ***