This page follows a CAN frame from the adapter to the screen: who receives it, where it is kept, how the interface reads it, and how frames per second and bus load are computed. Every live feature (plots, bus monitor, recording) reads frames this way.

Source files:

The path of a frame

flowchart LR
    A[Adapter] -->|USB / driver| B["python-can bus<br/>(can.Bus)"]
    B -->|"bus.recv()"| C["receive thread<br/>(can.Notifier)"]
    C --> D["canopen MessageListener<br/>SDO, PDO, NMT callbacks"]
    C --> E["TrafficListener"]
    C --> F["_BusWatcher<br/>error frames, lost adapter"]
    E --> G[("FrameBuffer<br/>ring of 262144 frames")]
    H["RecordingNetwork.send_message()<br/>frames sent by the app"] --> G
    G -->|"read_since(cursor)<br/>every 33 ms"| I["LiveData<br/>(QTimer, GUI thread)"]
    I -->|frames_received| J["plots, bus monitor<br/>(later tasks)"]
    I -->|"stats_updated<br/>every 500 ms"| K[status bar]
Loading
  1. One receive thread. ConnectionService opens one can.Bus and one canopen.Network, whose can.Notifier runs a single thread that calls bus.recv() and hands every message to its listeners. There is no other reading thread: python-can delivers each frame once, to everyone.
  2. Into the buffer. TrafficListener.on_message_received() appends the message to the FrameBuffer of the connection. It runs in the receive thread and does only that: a few microseconds per frame.
  3. Frames sent by the application. ConnectionService builds the network as a RecordingNetwork, whose send_message() sends the frame and then stores it with the TX flag. Sent frames take bus time too, and the bus monitor shows them. Periodic sending by python-can tasks (send_periodic, used for heartbeat or SYNC production) is not recorded; the application does not use it yet.
  4. To the interface. LiveData owns one QTimer at 30 Hz in the GUI thread. At every tick it takes what is new since its cursor and emits frames_received(frames); every 15 ticks (500 ms) it emits stats_updated(TrafficStats) for the status bar.

Why the GUI thread never touches the bus

Reading the bus blocks: bus.recv() waits for the next frame, a serial port can stall, a driver can take seconds to report an error. If the GUI thread did it, the window would freeze. The receive thread absorbs every wait; the GUI thread only copies from memory, under a lock held for microseconds. At 5000 frames/s a tick copies about 170 frames, which takes well under 5 ms of the 33 ms between ticks (a test checks it, NFR-PER-03).

For the same reason SDO requests, which wait for an answer, run in worker threads, and the connection is opened and closed in a worker (Connection).

The frame buffer

FrameBuffer is a preallocated numpy array of FRAME_DTYPE records, DEFAULT_CAPACITY = 2^18 = 262144 frames, about 52 s at 5000 frames/s and 12 MB of memory. A new buffer is created at every connection (ConnectionService.traffic).

Field Type Content
rx_time float64 time.monotonic() when the frame was stored: used for statistics
timestamp float64 timestamp given by python-can, from the adapter where it has one (FR-DAT-03)
can_id uint32 11 or 29 bit identifier
dlc uint8 data length
flags uint8 FLAG_EXTENDED, FLAG_RTR, FLAG_ERROR, FLAG_TX
data 8 × uint8 data bytes, zero-padded

The buffer also counts written (every frame since the connection), error_frames and tx_frames.

Readers and cursors

Any number of readers take frames, each with its own cursor, the value of written at its last read:

result = buffer.read_since(cursor)  # ReadResult(frames, cursor, lost)
cursor = result.cursor
  • frames is a copy, oldest first: the reader can keep it while the buffer moves on.
  • lost is the number of frames that were overwritten before the reader took them, because it fell more than one buffer behind. Frames are never lost silently: LiveData adds them up and the status bar shows "lost N" in red.
  • A reader that wants only new frames starts at buffer.written; one that wants everything still in memory starts at 0.

received_after(t) returns the frames stored after a given rx_time; it finds the start with a binary search, so its cost does not depend on how long the session has been running. latest(n) returns the last n frames.

Frames per second and bus load

compute_stats() (and ConnectionService.traffic_stats()) looks at the frames of the last second, the window (now − 1 s, now]:

  • frames/s: data and remote frames received or sent in the window. Error frames are counted apart (error_frames).
  • bus load %: estimated bits of those frames divided by the bitrate.

The exact length of a frame depends on bit stuffing (a bit added after five equal bits), which depends on its content. The load is therefore an estimate, close to what common CAN tools show:

Frame Nominal bits
standard identifier (11 bit) 47 + 8 × DLC
extended identifier (29 bit) 67 + 8 × DLC
remote frame as above with DLC counted as 0

The nominal length counts start of frame, arbitration, control, data, CRC, acknowledge, end of frame and the 3-bit interframe space. It is multiplied by STUFFING_FACTOR = 1.1 for the average stuffing; the real stuffing ranges from 0 to about 20% more. A full CAN 2.0A frame with 8 data bytes is thus 111 × 1.1 ≈ 122 bits.

The bitrate comes from the connection. With SocketCAN it is set in the operating system and the application does not know it: the load is None and the status bar shows "load -".

Add a consumer of live frames

A view that shows live data (a plot, the bus monitor) connects to LiveData.frames_received and filters what it needs, with numpy, without loops in Python:

def on_frames(self, frames: np.ndarray) -> None:
    mine = frames[frames["can_id"] == 0x180 + node_id]
    values = mine["data"][:, 0:2].copy().view("<i2")[:, 0]  # first INT16
    self.plot.append(mine["timestamp"], values)


window.live.frames_received.connect(view.on_frames)

Rules:

  • Do the work in a vectorised way and keep it short: the slot runs in the GUI thread, 30 times a second.
  • Never keep a reference into the buffer: frames is already a copy.
  • A consumer that must not miss frames even when the interface is busy (the recording, T4.3) reads the buffer with its own cursor in its own thread, and handles lost.

Tests

  • tests/test_frame_buffer.py: fields, cursors, wrap-around, lost, received_after().
  • tests/test_traffic_stats.py: bits per frame, load of a known traffic, window, error and sent frames, no bitrate.
  • tests/test_traffic_load.py: the acceptance test of T1.3. A generator sends 5000 frames/s for 30 s on the virtual bus; the application side, with a buffer of only about 3 s, must receive all 150,000 frames, in order, with lost = 0, and measure 5000 frames/s ± 10% in a one-second sample halfway (a busy runner makes the generator lag for a moment). It runs in every uv run pytest and takes 30 s.
  • tests/test_live_data.py: frames reach the GUI within 100 ms, a tick with 170 frames takes less than 5 ms, sent frames are recorded, the status bar shows frames/s and load in both languages, lost frames are shown.

Note for tests: can.Message has an extended identifier by default (is_extended_id=True). Test frames that stand for 11-bit CANopen frames must set is_extended_id=False, or the load is computed for 29-bit frames.