Skip to content

Python Script without GUI

ta1_k edited this page Aug 20, 2026 · 3 revisions

Using vs_controller without the GUI

vs_controller.py (at GUI/src/gui/controller/vs_controller.py) is self-contained: its only runtime dependency is pyserial. It can be imported and driven from any Python script — the GUI is one consumer of it, not a prerequisite.

Importing

No relative imports are used inside the file, so any of these work:

# Option A — script sits next to a copy of the file
from vs_controller import VoltageSourceController, DataLog

# Option B — reach into the source tree without installing
import sys, pathlib
sys.path.insert(0, str(pathlib.Path(
    "/home/ta1/SNSPD_multichannel_CurrentBias/GUI/src/gui/controller"
)))
from vs_controller import VoltageSourceController, DataLog

# Option C — install the package (`pip install -e .` from the GUI directory)
from gui.controller.vs_controller import VoltageSourceController, DataLog

Lifecycle

connect  →  start_reading  →  send_…  →  stop_reading  →  disconnect
  • connect opens the serial port and starts the 2 s cable-watchdog heartbeat.
  • start_reading spawns the background reader that parses data,… / calib,… lines and populates the per-channel ring buffer.
  • stop_reading closes any open sweep log and joins the reader.
  • disconnect stops the heartbeat and closes the port.

If you skip start_reading, no telemetry is parsed and has_new_data stays False. If you skip connect (opening serial.Serial yourself), the firmware zeros every channel after 2.5 s because no heartbeat is running.

Public API

Static helpers

  • VoltageSourceController.list_ports() → list[tuple[device, description]] — USB-looking devices sorted first (by VID + keyword score).
  • VoltageSourceController.guess_port() → str — best pick, or "" if nothing looks USB-ish.

Connection state

  • is_connected: bool (property)
  • connected_port: str (property)
  • active_sweep_channels() → list[int]

Command senders

All are fire-and-forget writes terminated with \0. Each returns False silently if the port is not open.

  • send_off(ch)
  • send_steady(ch, voltage, duration, time_unit) Runs channel ch at the constant DAC voltage. time_unit accepts the firmware's timer tokens ("Sec", "Min", "Hour") or "Inf", which runs indefinitely and ignores duration. "Inf" is the common case — use it unless you specifically want the firmware to auto-turn-off after a bounded interval.
  • send_sweep(ch, range_v, step_mv) — sweeps ±range_v in step_mv steps.
  • send_calibration(ch, r_1k, r_gain, dac_vref) — persisted in NVS on the ESP.
  • send_odr(ch, sps) — ADC output data rate.
  • send_command(raw: str) → bool — raw escape hatch.

Live data reads

The reader thread parses each data,… line into a DataLog and appends it to a bounded ring buffer per channel (deque(maxlen=4096)).

  • has_new_data(ch) → bool — set whenever a new sample has arrived since the last consume.
  • get_latest_sample(ch) → DataLog | None — returns the newest sample and clears the new-data flag. O(1); intended for the main consumer loop.
  • peek_latest_sample(ch) → DataLog | None — same, but does not touch the flag. Safe from auxiliary threads.
  • get_channel_data(ch) → list[DataLog] — full copy of the ring. Pay this cost only when you need the whole history (e.g. at sweep end).
  • clear_channel_data(ch) — wipe the ring. Call before a fresh sweep so points from a prior run do not linger.

DataLog fields:

channel_id: int
mode: int        # 0=SWEEP, 1=STEADY, 2=IDLE, 3=CALIBRATION, 4=ODR
voltage: float   # V
current: float   # µA
time_s: float    # seconds since firmware boot (NOT wall time)

Sweep TXT logging

Automatic once start_reading is running: every data,… line with mode == 0 is written to the channel's open sweep file.

  • start_sweep_log(ch) → path — auto-rotates by timestamp.
  • stop_sweep_log(ch)
  • sweep_log_path(ch) → str

The start_steady_log / write_steady_row helpers are shaped around the GUI's meter-poll workflow (hard-coded pcb_current_uA + per-meter columns, row written only when the caller explicitly hands over a meter reading). For a pcb-only headless recording, ignore those helpers and stream peek_latest_sample(ch) yourself — see the steady example below.

Callbacks

Optional. Both default to None.

  • vs.log_callback = fn(msg: str) — every non-data, line from the firmware (boot banners, ESP_LOGx, printf, watchdog messages).
  • vs.calib_callback = fn(ch, r_1k, r_gain, dac_vref) — fires when the firmware sends a calib,… line (in reply to send_calibration, and on every boot).

Threads

All threads are daemon threads and live entirely inside vs_controller — no external ticker is required.

  1. Reader thread (start_reading) — parses data,… and calib,…; forwards everything else to log_callback; writes sweep rows.
  2. Heartbeat thread (connect) — writes hb every 2 s. The firmware zeros every channel after 2.5 s without input. connect starts it, disconnect stops it.
  3. Reconnect thread — appears only after a USB drop, polls list_ports() for the last-known device, and re-runs connect + start_reading when it reappears. Bounded by _reconnect_timeout_s = 30 s. Set vs._auto_reconnect = False before disconnect() to opt out.

A diagnostic file vs_diag_<timestamp>.log is opened in output_dir on each connect. It captures every non-data, line and heartbeat scheduling gaps. Line-buffered so it survives a killed process.

Gotchas

  • connect alone does not spawn the reader — you must call start_reading.
  • The ring buffer is bounded at 4096 samples. Fine for typical sweeps (~3000 points at 1.5 V range / 1 mV step). Very fine sweeps overflow and the oldest samples drop off the head; the sweep TXT is unaffected because it is written straight to disk.
  • send_command returns False silently if the port is not open. Check the return value or is_connected if you care.
  • DataLog.time_s is a firmware clock, not epoch. Stamp time.time() yourself when you read if you need wall time.
  • The class is thread-safe for the exposed operations. Do not reach into _serial or _data_buffers directly — use the accessors above.

Example — steady

import csv
import time
from vs_controller import VoltageSourceController

vs = VoltageSourceController()
vs.log_callback = lambda s: print("[esp]", s)

vs.connect(vs.guess_port(), 115200)
vs.start_reading(output_dir="output")

ch, applied_v = 0, 0.25

# Run indefinitely — "Inf" ignores the duration argument.
vs.send_steady(ch, applied_v, 0, "Inf")

# Bounded run (firmware auto-turns off after `duration` `unit`s):
# vs.send_steady(ch, applied_v, 300, "Sec")

path = f"output/pcb_ch{ch}_{int(time.time())}.txt"
with open(path, "w", newline="") as f:
    w = csv.writer(f, delimiter="\t")
    w.writerow(["wall_time", "voltage_V", "pcb_current_uA"])
    try:
        while vs.is_connected:
            s = vs.peek_latest_sample(ch)
            if s is not None:
                w.writerow([f"{time.time():.3f}",
                            f"{s.voltage:.6f}",
                            f"{s.current:.6f}"])
                f.flush()
            time.sleep(1.0)   # sampling cadence
    except KeyboardInterrupt:
        pass
    finally:
        vs.send_off(ch)
        vs.stop_reading()
        vs.disconnect()

Example — sweep

import time
from vs_controller import VoltageSourceController

vs = VoltageSourceController()
vs.log_callback = lambda s: print("[esp]", s)

vs.connect(vs.guess_port(), 115200)
vs.start_reading(output_dir="output")

ch = 0
vs.clear_channel_data(ch)            # discard any prior samples
vs.start_sweep_log(ch)               # per-channel TXT, auto-filled by the reader
vs.send_sweep(ch, range_v=1.0, step_mv=10)

try:
    # Wait for the firmware to report OFF (mode == 2) after finishing the sweep.
    while vs.is_connected:
        s = vs.peek_latest_sample(ch)
        if s is not None and s.mode >= 2:
            break
        time.sleep(0.1)

    data = vs.get_channel_data(ch)   # full sweep, in order
    print(f"sweep collected {len(data)} points → {vs.sweep_log_path(ch)}")
finally:
    vs.stop_sweep_log(ch)
    vs.send_off(ch)
    vs.stop_reading()
    vs.disconnect()