Repository navigation
Entities and Polling
Which SSC path feeds which Home Assistant entity, and how often it is read. Types, ranges and whether a path can be written: SSC Paths in the Neumann KH SSC Reference.
Source marks: see the legend on Home. Everything on this page is [code] unless marked otherwise.
Poll rates: fast = every cycle (30 s); fast, while enabled = every cycle, but only while an entity that reads the path is enabled (otherwise not polled; the first refresh after setup reads it once); slow = every 10th cycle (5 min), cached in between; setup = read once when the entry is set up; none = never polled.
| Path | Poll | Entity / use |
|---|---|---|
device/identity/product |
setup | device model |
device/identity/vendor |
setup (config flow) | device manufacturer, Neumann check |
device/identity/serial |
setup | config entry unique ID |
device/identity/version |
setup | firmware version (device info) |
device/identity/hw_version |
slow | sensor Hardware version |
| Path | Poll | Entity |
|---|---|---|
device/standby/enabled |
fast | KH 120 II: switch Auto standby; KH 750: binary sensor Auto standby (the KH 750 follows its rear switch and refuses writes [measured]) |
device/standby/auto_standby_time |
fast | number Auto standby time |
device/standby/level |
fast | number Standby threshold level |
device/standby/countdown |
fast, while enabled | sensor Standby countdown (disabled by default) |
| Path | Poll | Entity |
|---|---|---|
audio/out/level |
fast | number Output level (step 0.5) |
audio/out/delay |
fast | number Delay |
audio/out/mute |
fast | switch Mute |
audio/out/phaseinversion |
fast (non-subwoofer models) | switch Phase invert (non-subwoofer models) |
audio/out/label |
slow | sensor Output label |
audio/out5/level, audio/out5/mute
|
fast, only when detected | same entities as audio/out/level and audio/out/mute (see Integration-Behaviour) |
audio/out1/level, audio/out2/level
|
fast, while enabled | numbers Output 1 level, Output 2 level (disabled by default) |
audio/out1/delay, audio/out2/delay
|
fast, while enabled | numbers Output 1 delay, Output 2 delay (disabled by default) |
audio/out1/mute, audio/out2/mute
|
fast, while enabled | switches Output 1 mute, Output 2 mute (disabled by default) |
audio/out1/label, audio/out2/label
|
slow | sensors Output 1 label, Output 2 label (disabled by default) |
audio/out1/loudspeaker, audio/out2/loudspeaker
|
slow | sensors Output 1 loudspeaker, Output 2 loudspeaker (disabled by default) |
audio/in/interface |
slow | select Input interface |
audio/in/current_input |
slow | sensor Current input |
audio/digital_bypass |
slow | binary sensor Digital bypass |
On the KH 750, "Output 1" and "Output 2" are the output sockets A and B [measured].
All except ui/logo/brightness are read-only sensors: the speakers refuse writes to them [measured]. Logo brightness is a writable number and part of the backup restore [code].
| Path | Poll | Entity |
|---|---|---|
ui/logo/brightness |
fast | number Logo brightness (not polled on the KH 750) |
ui/input_gain |
slow | sensor Input gain |
ui/input_select |
slow | sensor Input select |
ui/bass_gain, ui/mid_gain, ui/treble_gain
|
slow | sensors Bass gain, Mid gain, Treble gain |
ui/output_level |
slow | sensor Output level (SPL) |
ui/control_mode |
fast | sensor Control mode (diagnostic) |
ui/bass_management |
slow | sensor Bass management |
ui/channel_b_input_mode |
slow | sensor Channel B input mode |
ui/subwoofer_input_gain |
slow | sensor Subwoofer input gain |
ui/subwoofer_low_cut |
slow | sensor Subwoofer low cut |
ui/subwoofer_output_level |
slow | sensor Subwoofer output level |
ui/subwoofer_phase |
slow | sensor Subwoofer phase |
ui/subwoofer_phase_inversion |
slow | sensor Subwoofer phase inversion |
ui/auto_standby is not used.
| Path | Poll | Entity |
|---|---|---|
device/name |
slow | text Device name (disabled by default) |
device/identification/visual |
fast | switch Identify |
device/restore |
none | button Restore factory defaults (disabled by default; second press 2–30 s after the first) |
device/save_settings |
none | no entity; sent to the KH 80 only (see Integration-Behaviour) |
device/temperature |
fast | sensor Device temperature (shown in °C) |
| Path | Poll | Entity |
|---|---|---|
m/in/level |
fast | sensor Input level (live) |
m/in/clip |
fast | binary sensor Input clipping (on if any channel clips) |
m/out/level |
fast, while enabled | sensor Output level (live) (disabled by default) |
m/out/clip |
fast, while enabled | binary sensor Output clipping (disabled by default) |
warnings |
fast | binary sensor Warning (on for anything other than NO_WARNING) |
Meters and the standby countdown are left out of backups.
| Leaf | Poll | Entity |
|---|---|---|
enabled |
slow | switch {container} enabled (writes the whole array; on if any band is on) |
gain, boost
|
none | set to 0 by button {container}: reset to flat |
frequency, q, type
|
none | – (backup only) |
The crossover eq1/in1|in2 of the KH 750 is not used. Details: Integration-Behaviour.
See also: Integration-Behaviour · Troubleshooting
Neumann Connect Wiki