Version
7.1.12
Host OS Type
Windows
Host OS name + version
Windows 10 Pro, 22H2, build: 19045.6093
Host Architecture
x86
Guest OS Type
Windows
Guest Architecture
x86
Guest OS name + version
Windows 10 Pro, 22H2, build: 19045.6093
Component
WDDM / Additions
What happened?
Since updating from Virtualbox build 7.0.22, multi-monitor support is broken on my system.
When clicking enable of the 2nd display in the view menu, the 2nd monitor does not display or enable.
I recall that the update of guest additions away from 7.0.22 failed and was difficult to recover from. The system had both guest additions installed at the same time and both had to be uninstalled. From there I ran GA 7.0.22 until the next version came out with the fixed GA installer.
I have tried every release since to no avail. Initially, by downgrading guest additions to 7.0.22 the symptoms were resolved.
Current build is: 7.2.0_RC1 r169991, but again I have tried every stable release and many dev snapshots trying to resolve this issue.
This is logged the first attempt to enable the 2nd display after a clean boot:
00:01:42.940416 GUI: UIMachineView::sltHandleActionTriggerViewScreenToggle: Enabling guest-screen 1
00:01:42.940451 VMMDev: SetVideoModeHint: Got a video mode hint (640x480x0)@(0x0),(1;0) at 1
00:01:42.940606 VMMDev: Guest Log: 00:00:43.844711 display Got multi resize request 1 displays
00:01:42.940652 VMMDev: Guest Log: 00:00:43.844766 display [0]: 1 0x38 0,0 640x480 0
00:01:42.941770 VMMDev: Guest Log: 00:00:43.845880 display VBoxDispIfResizeDisplayWin7Wddm: VBoxTray: (WDDM) invalid bpp 0, using 32bpp instead
00:01:42.941853 VMMDev: Guest Log: 00:00:43.845971 display VBoxDispIfResizeDisplayWin7Wddm: VBoxTray:(WDDM) pfnSetDisplayConfig Failed to VALIDATE winEr 87.
00:01:42.941891 VMMDev: Guest Log: 00:00:43.846013 display VBoxDispIfResizeDisplayWin7Wddm: VBoxTray:(WDDM) pfnSetDisplayConfig Failed to SET, winEr 87.
00:01:42.942687 VMMDev: Guest Log: 00:00:43.846787 display VBoxDispIfResizeDisplayWin7Wddm: VBoxTray:(WDDM) pfnSetDisplayConfig Failed to APPLY TOPOLOGY ONLY, winEr 31.
00:01:42.943615 VMMDev: Guest Log: 00:00:43.847723 display VBoxDispIfResizeDisplayWin7Wddm: VBoxTray:(WDDM) pfnSetDisplayConfig Failed to APPLY ANY TOPOLOGY, winEr 31.
It appears the issue may be with the command being sent to SetDisplayConfig.
Here's the full log:
VM-2025-08-12-08-53-29.log
How can we reproduce this?
possibly by upgrading GA-7.0.22 ---> GA-7.1.0
Did you upload all of your necessary log files, screenshots, etc.?