Binary file added example energyplus data model/.DS_Store
Binary file not shown.
1,924 changes: 1,924 additions & 0 deletions example energyplus data model/aeChack.idf

Large diffs are not rendered by default.

2,874 changes: 2,874 additions & 0 deletions example energyplus data model/aeChack.osm

Large diffs are not rendered by default.

Binary file not shown.

Large diffs are not rendered by default.

990 changes: 990 additions & 0 deletions example energyplus data model/aeChack/project.log

Large diffs are not rendered by default.

Binary file not shown.
Binary file not shown.
Binary file added example energyplus data model/aeChack/run.db
Binary file not shown.
Binary file not shown.
2,172 changes: 2,172 additions & 0 deletions example energyplus data model/aeChack/run/1-ModelToIdf-0/in.idf

Large diffs are not rendered by default.

2,227 changes: 2,227 additions & 0 deletions example energyplus data model/aeChack/run/2-ExpandObjects-0/expanded.idf

Large diffs are not rendered by default.

Original file line number Diff line number Diff line change
@@ -0,0 +1,4 @@
ExpandObjects Started.
Begin reading Energy+.idd file.
Done reading Energy+.idd file.
ExpandObjects Finished. Time: 0.046
2,443 changes: 2,443 additions & 0 deletions example energyplus data model/aeChack/run/3-EnergyPlusPreProcess-0/out.idf

Large diffs are not rendered by default.

Original file line number Diff line number Diff line change
@@ -0,0 +1,3 @@

[program]
dir=
2,564 changes: 2,564 additions & 0 deletions example energyplus data model/aeChack/run/4-EnergyPlus-0/eplusout.audit

Large diffs are not rendered by default.

110 changes: 110 additions & 0 deletions example energyplus data model/aeChack/run/4-EnergyPlus-0/eplusout.bnd
Original file line number Diff line number Diff line change
@@ -0,0 +1,110 @@
Program Version,EnergyPlus-Darwin-OMP-64 8.0.0.008, YMD=2013.11.09 12:26
! This file shows details about the branches, nodes, and other
! elements of the flow connections.
! This file is intended for use in "debugging" potential problems
! that may also be detected by the program, but may be more easily
! identified by "eye".
! This file is also intended to support software which draws a
! schematic diagram of the HVAC system.
! ===============================================================
! #Nodes,<Number of Unique Nodes>
#Nodes,3
! <Node>,<NodeNumber>,<Node Name>,<Node Fluid Type>,<# Times Node Referenced After Definition>
Node,1,THERMALZONE01 ZONE AIR NODE,Air,0
Node,2,THERMALZONE01 RETURN OUTLET,Air,0
Node,3,THERMALZONE01 SUPPLY INLET,Air,1
! ===============================================================
! Suspicious nodes have 0 references. It is normal for some nodes, however.
! Listing nodes with 0 references (culled from previous list):
! <Suspicious Node>,<NodeNumber>,<Node Name>,<Node Fluid Type>,<# Times Node Referenced After Definition>
Suspicious Node,1,THERMALZONE01 ZONE AIR NODE,Air,0
Suspicious Node,2,THERMALZONE01 RETURN OUTLET,Air,0
! ===============================================================
! <#Branch Lists>,<Number of Branch Lists>
#Branch Lists,0
! <Branch List>,<Branch List Count>,<Branch List Name>,<Loop Name>,<Loop Type>,<Number of Branches>
! <Branch>,<Branch Count>,<Branch Name>,<Loop Name>,<Loop Type>,<Branch Inlet Node Name>,<Branch Outlet Node Name>
! ===============================================================
! <#Supply Air Paths>,<Number of Supply Air Paths>
#Supply Air Paths,0
! <Supply Air Path>,<Supply Air Path Count>,<Supply Air Path Name>,<AirLoopHVAC Name>
! <#Components on Supply Air Path>,<Number of Components>
! <Supply Air Path Component>,<Component Count>,<Component Type>,<Component Name>,<AirLoopHVAC Name>
! <#Outlet Nodes on Supply Air Path Component>,<Number of Nodes>
! <Supply Air Path Component Nodes>,<Node Count>,<Component Type>,<Component Name>,<Inlet Node Name>,<Outlet Node Name>,<AirLoopHVAC Name>
! ===============================================================
! <#Return Air Paths>,<Number of Return Air Paths>
#Return Air Paths,0
! <Return Air Path>,<Return Air Path Count>,<Return Air Path Name>,<AirLoopHVAC Name>
! <#Components on Return Air Path>,<Number of Components>
! <Return Air Path Component>,<Component Count>,<Component Type>,<Component Name>,<AirLoopHVAC Name>
! <#Inlet Nodes on Return Air Path Component>,<Number of Nodes>
! <Return Air Path Component Nodes>,<Node Count>,<Component Type>,<Component Name>,<Inlet Node Name>,<Outlet Node Name>,<AirLoopHVAC Name>
! ===============================================================
! #Outdoor Air Nodes,<Number of Outdoor Air Nodes>
#Outdoor Air Nodes,0
! ===============================================================
! <#Component Sets>,<Number of Component Sets>
#Component Sets,0
! <Component Set>,<Component Set Count>,<Parent Object Type>,<Parent Object Name>,<Component Type>,<Component Name>,<Inlet Node ID>,<Outlet Node ID>,<Description>
! ===============================================================
! <# Plant Loops>,<Number of Plant Loops>
#Plant Loops,0
! <Plant Loop>,<Plant Loop Name>,<Loop Type>,<Inlet Node Name>,<Outlet Node Name>,<Branch List>,<Connector List>
! <Plant Loop Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <Plant Loop Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <Plant Loop Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! <Plant Loop Supply Connection>,<Plant Loop Name>,<Supply Side Outlet Node Name>,<Demand Side Inlet Node Name>
! <Plant Loop Return Connection>,<Plant Loop Name>,<Demand Side Outlet Node Name>,<Supply Side Inlet Node Name>
! ===============================================================
! <# Condenser Loops>,<Number of Condenser Loops>
#Condenser Loops,0
! <Condenser Loop>,<Condenser Loop Name>,<Loop Type>,<Inlet Node Name>,<Outlet Node Name>,<Branch List>,<Connector List>
! <Condenser Loop Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <Condenser Loop Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <Condenser Loop Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! <Condenser Loop Supply Connection>,<Condenser Loop Name>,<Supply Side Outlet Node Name>,<Demand Side Inlet Node Name>
! <Condenser Loop Return Connection>,<Condenser Loop Name>,<Demand Side Outlet Node Name>,<Supply Side Inlet Node Name>
! ===============================================================
! <# Controlled Zones>,<Number of Controlled Zones>
#Controlled Zones,1
! <Controlled Zone>,<Controlled Zone Name>,<Equip List Name>,<Control List Name>,<Zone Node Name>,<Return Air Node Name>,<# Inlet Nodes>,<# Exhaust Nodes>
! <Controlled Zone Inlet>,<Inlet Node Count>,<Controlled Zone Name>,<Supply Air Inlet Node Name>,<SD Sys:Cooling/Heating [DD:Cooling] Inlet Node Name>,<DD Sys:Heating Inlet Node Name>
! <Controlled Zone Exhaust>,<Exhaust Node Count>,<Controlled Zone Name>,<Exhaust Air Node Name>
Controlled Zone,THERMALZONE01,THERMALZONE01 EQUIPMENT,,THERMALZONE01 ZONE AIR NODE,THERMALZONE01 RETURN OUTLET,1,0
Controlled Zone Inlet,1,THERMALZONE01,THERMALZONE01 SUPPLY INLET,Undefined,N/A
! ===============================================================
! <#Zone Equipment Lists>,<Number of Zone Equipment Lists>
#Zone Equipment Lists,1
! <Zone Equipment List>,<Zone Equipment List Count>,<Zone Equipment List Name>,<Zone Name>,<Number of Components>
! <Zone Equipment Component>,<Component Count>,<Component Type>,<Component Name>,<Zone Name>,<Heating Priority>,<Cooling Priority>
Zone Equipment List,1,THERMALZONE01 EQUIPMENT,THERMALZONE01,1
Zone Equipment Component,1,ZONEHVAC:IDEALLOADSAIRSYSTEM,THERMALZONE01ZONEHVAC:IDEALLOADSAIRSYSTEM,THERMALZONE01,1,1
! ===============================================================
! <#Dual Duct Damper Connections>,<Number of Dual Duct Damper Connections>
#Dual Duct Damper Connections,0
! <Dual Duct Damper>,<Dual Duct Damper Count>,<Dual Duct Damper Name>,<Inlet Node>,<Outlet Node>,<Inlet Node Type>,<AirLoopHVAC Name>
! ===============================================================
! <#AirLoopHVACs>,<Number of AirLoopHVACs>
#AirLoopHVACs,0
! <AirLoopHVAC>,<Air Loop Name>,<# Return Nodes>,<# Supply Nodes>,<# Zones Cooled>,<# Zones Heated>,<Outdoor Air Used>
! <AirLoop Return Connections>,<Connection Count>,<AirLoopHVAC Name>,<Zn Eqp Return Node #>,<Zn Eqp Return Node Name>,<AirLoop Return Node #>,<Air Loop Return Node Name>
! <AirLoop Supply Connections>,<Connection Count>,<AirLoopHVAC Name>,<Zn Eqp Supply Node #>,<Zn Eqp Supply Node Name>,<AirLoop Supply Node #>,<Air Loop Supply Node Name>
! <Cooled Zone Info>,<Cooled Zone Count>,<Cooled Zone Name>,<Cooled Zone Inlet Node #>,<Cooled Zone Inlet Node Name>,<AirLoopHVAC Name>
! <Heated Zone Info>,<Heated Zone Count>,<Heated Zone Name>,<Heated Zone Inlet Node #>,<Heated Zone Inlet Node Name>,<AirLoopHVAC Name>
! <Outdoor Air Connections>,<OA Inlet Node #>,<OA Return Air Inlet Node Name>,<OA Outlet Node #>,<OA Mixed Air Outlet Node Name>,<AirLoopHVAC Name>
! <AirLoopHVAC Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <AirLoopHVAC Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <AirLoopHVAC Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! ===============================================================
! <#Parent Node Connections>,<Number of Parent Node Connections>
#Parent Node Connections,0
! <Parent Node Connection>,<Node Name>,<Node ObjectType>,<Node ObjectName>,<Node ConnectionType>,<Node FluidStream>
! ===============================================================
! <#Non-Parent Node Connections>,<Number of Non-Parent Node Connections>
#Non-Parent Node Connections,4
! <Non-Parent Node Connection>,<Node Name>,<Node ObjectType>,<Node ObjectName>,<Node ConnectionType>,<Node FluidStream>
Non-Parent Node Connection,THERMALZONE01 ZONE AIR NODE,ZONEHVAC:EQUIPMENTCONNECTIONS,THERMALZONE01,ZoneNode,1
Non-Parent Node Connection,THERMALZONE01 RETURN OUTLET,ZONEHVAC:EQUIPMENTCONNECTIONS,THERMALZONE01,ZoneReturn,1
Non-Parent Node Connection,THERMALZONE01 SUPPLY INLET,ZONEHVAC:EQUIPMENTCONNECTIONS,THERMALZONE01,ZoneInlet,1
Non-Parent Node Connection,THERMALZONE01 SUPPLY INLET,ZONEHVAC:IDEALLOADSAIRSYSTEM,THERMALZONE01ZONEHVAC:IDEALLOADSAIRSYSTEM,Outlet,1