Skip to content

Conversation

mihnagy
Copy link
Contributor

@mihnagy mihnagy commented Aug 10, 2021

Tested on ZC706 + DAQ2

@CLAassistant
Copy link

CLAassistant commented Aug 10, 2021

CLA assistant check
All committers have signed the CLA.

@mihnagy mihnagy requested a review from a team August 10, 2021 08:33
@Yamakaja
Copy link
Contributor

Did you run the testbenches against this modification? I'd be interested specifically in the outcome when the ready / valid signals aren't constantly high but oscillating (0, 0, 0, 1, repeat), for the case where those are always high i agree that the behavior should be identical.

@mihnagy
Copy link
Contributor Author

mihnagy commented Aug 10, 2021

tlast should be generated on the last data beat while having tvalid and tready both active. Regardless of them switching constantly or not, the data should be valid and counted only when valid and ready are both active.

@mihnagy mihnagy closed this Aug 20, 2021
@mihnagy mihnagy deleted the data_offload_fixes branch August 20, 2021 07:42
@mihnagy mihnagy restored the data_offload_fixes branch September 20, 2021 10:39
@mihnagy mihnagy reopened this Sep 20, 2021
@mihnagy mihnagy requested a review from acostina September 21, 2021 13:00
@acostina
Copy link
Contributor

acostina commented Sep 22, 2021

Can you squash the two commits into a single one ?
Otherwise, looks good.

@mihnagy
Copy link
Contributor Author

mihnagy commented Sep 22, 2021

Ok, done

@mihnagy mihnagy merged commit 1fe0d5f into analogdevicesinc:master Sep 22, 2021
@Yamakaja
Copy link
Contributor

@mihnagy I'm sorry i didn't get to test this properly before, but i believe the changes in this PR broke something about my OFDM radar ... not yet sure what exactly went wrong.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment