What's new
Scope record memory
- The status bar shows the memory budget for the displayed record. A label such as
<512Kmeans the record used fewer points than the budget. Fast acquisitions can reserve some of that memory for DMA. - Analyze → Acquisition → Captured shows the exact sample count per channel. In HOLD, the overview follows the held record when you change the budget for the next acquisition. Issue #131
Multimeter charge counter
- The DC A and DC mA screens show signed charge in mAh or Ah beside the range, in both the digital and analog layouts.
- The total resets when you switch DMM functions or enter the multimeter. Changing range or selecting the same function again keeps it. Local HOLD and REL affect the displayed current while the counter continues to use live readings. Missing, stale, or invalid readings pause the integration. Issue #132
Settings uptime
The Settings header shows time since the firmware started and updates once a second.
Testing
Development builds were checked on a ZT703S. The scope showed the budget and the exact acquired length separately, including when a new budget was selected in HOLD. In the multimeter, the charge counter appeared in DC A and DC mA, while AC still showed frequency. Uptime advanced with Settings open.
Firmware and Recovery builds passed for both models. Host tests with known current packets covered signed integration, range changes, interrupted readings, HOLD, and resets. Scope UI, update validation, and application stack-budget checks passed.
Files
| Device | Recovery bootloader | Firmware |
|---|---|---|
| ZT703S | OpenOSC-Recovery-ZT703S.ZTK |
OpenOSC-Firmware-ZT703S.OSC |
| ZT706S | OpenOSC-Recovery-ZT706S.ZTK |
OpenOSC-Firmware-ZT706S.OSC |
Download the files for your model.
Updating
- From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching
.OSCfile into/openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION. - The Recovery packages match 0.21.9 byte for byte. If Recovery is already installed, update the firmware alone.
- From 0.2.0 or older, or for a new installation — Follow the installation instructions.
Known issues
- Continuous envelope transfers scan the full record and can reduce the waveform update rate with deep memory. For fresh-frame queries at slow timebases, set the host read timeout above the configured record duration plus one second.
- CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
- Dense two-channel captures with waveform density enabled can reduce the display frame rate.
- A single-slot capture can reuse the previous record's memory. If this happens while waiting for a trigger, panning becomes available once a new record is captured.
- Settings are saved at an orderly power-off, restart or Recovery entry. Unexpected power loss can discard changes made since the last save.
- USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
SHA-256
e2183271a1be97bc6599d43a10bf6d9f977226d39d12d2cbe9aea9baf3ad221d OpenOSC-Firmware-ZT703S.OSC
8a07cae2a45e3ab77b008d2ed9676e3b59060824abeb790841935b10ef93109a OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81 OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2 OpenOSC-Recovery-ZT706S.ZTK