Skip to content

Releases

OpenOSC 0.21.7

Choose a tag to compare

@bve bve released this 24 Nov 02:45

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. Return to the stock firmware.

What's new

Roll waveform stability

Completed waveform columns keep their samples as the trace scrolls. The newest column fills in from incoming samples, which prevents the stored part of the trace from flickering at slow timebases.

Bode markers and saved setup

  • The plot marks f1 and f2 on either side of a band-pass peak or a notch when the sweep covers both crossings. It also marks the peak or notch itself. The notch cutoffs use the passband level on each side. #122
  • Bode sweep settings, including the frequency range, point density, settling time, averages, and drive settings, are retained across an orderly power-off or restart. #124

Thanks to @taylora1-1 for the reports and the filter examples.

Trigger and cursor controls

  • With the Trigger card selected, Left and Right adjust the pretrigger from 0% to 100%. Each press changes it by one percentage point, and each held repeat changes it by five. Hold F3 to set pretrigger to 50% and place the trigger level at the midpoint of a completed signal capture. Use F2 to pan. Changes in HOLD or after a completed Single take effect on the next acquisition. #123
  • After returning from Cursor settings opened by holding F4, the first enabled cursor is selected automatically. The arrows move Time A, or Level A when only voltage cursors are enabled. #125

Thanks to @TzOk83 and @taylora1-1 for the control suggestions.

Boot credits

Added Fyfar to the donors list. Thank you for supporting the project.

Testing

The firmware and Recovery built for both models. Host tests covered Bode cutoffs for band-pass and twin-T notch data, saved sweep settings, trigger controls, cursor navigation, Roll rendering, and firmware update validation. On the ZT703S bench, the fixes were checked for stable Roll history, Bode setup after a restart, the trigger position in captured data, HOLD and Single, and movement of both types of cursor.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC file into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • The Recovery packages match 0.21.6 byte for byte. If Recovery is already installed, update the firmware alone.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In single-slot configurations, an armed capture can reuse the previous record's memory. In WAIT, panning is unavailable until a new record is captured. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. An unexpected power loss can discard settings changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

f667fe75d231543195a68885bf2f98354de8f6c0bfb50e4e3c8355b3b42c949f  OpenOSC-Firmware-ZT703S.OSC
4b681a4105c8b10a467c7d004093d2e15399ecdbb5907d0a43f94568b3f59140  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.6

Choose a tag to compare

@bve bve released this 23 Nov 16:58

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. Return to the stock firmware.

What's new

Multimeter diode-test scale (#116)

The analog dial and digital bar now use a 0–3.3 V scale on both models. The scale appears as soon as diode mode reports a reading or OL. The needle and bar track the measured voltage.

Thanks to @LeonIndman for the report.

Boot credits

Added RAPO to the donors list. Thank you for supporting the project.

Testing

Built the firmware and Recovery for both models. Native DMM model tests verified the diode scale, normal readings and overload on both models. The ZT703S screen rendering, update validation and stack checks passed. This release was verified without flashing a physical device.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.5 byte for byte. If Recovery is already installed, update the firmware alone.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In single-slot configurations, an armed capture can reuse the previous record's memory. In WAIT, panning is unavailable until a new record is captured. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. An unexpected power loss can discard settings changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

effc9421a2568c573938bdd10bfb8aa8481858c84ccc7a9f472f96a75d5359ee  OpenOSC-Firmware-ZT703S.OSC
2b6759fcf6bb2e11e054fcd631e01b6358e02eaf35b0972cfbc025444980effc  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.5

Choose a tag to compare

@bve bve released this 23 Nov 13:34

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. Return to the stock firmware.

What's new

Scope panning and zoom (#106, #109, #111)

  • Panning follows the next frame when a running capture is reusing the previous frame's memory. At 512K points, this removes the misleading No record to move popup during normal acquisition.
  • Zoom & Pan reports a zoom limit when the requested span cannot fit in the record. If a later capture is shorter than the existing zoomed-out view, the screen shows ZOOM all.
  • The ZOOM and PAN indicators remain visible after leaving Zoom & Pan with Back. Successful Auto Setup returns the view to its default zoom and pan.

Battery display calibration (#107)

Settings → Device → Power has Battery gain and Battery offset controls. They let you align the displayed voltage with an external meter and also adjust the estimated charge percentage and bars. The low-battery shutdown threshold uses the factory reading.

Tooltip controls (#108)

Choose which tooltip categories to show in Settings → Display → Tooltips. Usage tips, unavailable actions, progress, completions and advisory warnings each have a switch. Critical alerts are always shown.

Analog multimeter scale (#112)

Scale labels use the size of the displayed digits to clear the arc, tick marks and needle. This also keeps longer Type K labels readable.

Thanks to @art-thunder, @OlegMedvedcuk, @Fyfar and @LeonIndman for the reports and suggestions.

Testing

Verified the 512K panning fix, Zoom & Pan limits, Auto Setup, tooltip controls, battery calibration and analog multimeter scales on the ZT703S during development. The reported 0–1500 °C dial was also checked in a rendering test. The 0.21.5 firmware was installed and checked in Scope and DMM modes on the ZT703S. The native DMM model, settings layout, scope controller and rendering suites passed. Both models passed the application and Recovery builds, package validation and stack checks.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.4 byte for byte. If Recovery is already installed, update the firmware alone.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In single-slot configurations, an armed capture can reuse the previous record's memory. In WAIT, panning is unavailable until a new record is captured. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. An unexpected power loss can discard settings changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

7bc3b5663bfc7af2a759c72d879bd8b66971fd72541fb543f153955372842e8f  OpenOSC-Firmware-ZT703S.OSC
89e0aa023f9061b4da1e6c0d5a2fe9fc0ce236c2ce504af3ac1deac1a0d0ed4b  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.4

Choose a tag to compare

@bve bve released this 23 Nov 03:21

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Scope trigger level limits (#61)

The arrow at the right edge of the plot pulses for half a second when the trigger level reaches either limit or you press against it. A small warning triangle stays beside the arrow while the level is at the limit. The trace and soft keys stay visible. In the Trigger panel, the Level row shows (min) or (max).

Thanks to @art-thunder for the suggestion.

Hold MODE to switch between the scope and generator

Hold MODE for 1 s to switch directly between Oscilloscope and Generator. Holding MODE from Multimeter opens the oscilloscope. A tap still cycles through all three screens. Each hold switches once. See Controls.

Testing

Installed the 0.21.4 application package through Recovery on a ZT703S. Verified both trigger limits in HOLD, including the pulse, the persistent marker and an inward step on the same record. Checked MODE holds in both directions and from the multimeter, the short-press cycle, and the USB Remote lock. Native input and rendering tests and stack checks passed. Both models passed application and Recovery builds and package validation.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.3 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. Changes made since the last save can be lost if power is interrupted.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

8a826b3dfa0e21086774a2a4cb74e1adf4ff774a8fd33d02b7326a0ccfa60266  OpenOSC-Firmware-ZT703S.OSC
e94cf4afbcdc8b825be02b76ba5a7198d194f435f6f6acc8c6e635f189a4c180  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.3

Choose a tag to compare

@bve bve released this 23 Nov 02:51

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Scope grid and trace brightness (#86)

Use Analyze → Display → View → Grid brightness for the grid (0–100%) and Channel → Trace brightness for each channel (10–100%). All three default to 100% and adjust in 10% steps. Trace brightness also applies to Density, Glow, Persistence, Peak Hold and the XY trace (CH1). Channel labels and trigger markers keep their contrast.

Thanks to @OlegMedvedcuk for the suggestion.

Auto power off on battery (#104)

The external-power status pin can stay high after USB disconnects. The idle timer now runs in standalone mode despite that pin state. An active USB host or work such as generator output or recording still keeps the instrument on. Charging from a USB supply without a data host allows the timer to run.

Screenshot names after clearing (#105)

New screenshots include a checksum of their pixels in the name, for example SCR00001-644DF03C.BMP. This gives different screenshots different names when the same sequence number is reused after clearing. The image browser continues to support older SCRnnnnn.BMP files.

Thanks to @StrontiumD for both reports.

Testing

Installed the release package through Recovery on a ZT703S and checked the running version and waveform transfer over USB. On the same device, feature tests covered independent brightness in HOLD and after restart, auto power-off with the idle timer brought close to its deadline over SWD, and reading new screenshots through Recovery on Linux after deletion and reboot. Both models passed application and Recovery builds, package validation and stack checks. Native tests covered the FAT screenshot workflow, timer boundaries and settings.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.2 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. Changes made since the last save can be lost if power is interrupted.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

64005501eb27012ef71fdabb5850d9f073ef6463ab58eb673331e406f37a6bf8  OpenOSC-Firmware-ZT703S.OSC
3f4af48cc1a3512a08ee61d71f5c539fd10cc376a907210c8a8a5944b0e75d64  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.2

Choose a tag to compare

@bve bve released this 23 Nov 01:48

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Screenshot cleanup progress (#102)

Settings → Files & USB → Clear screenshots now counts the BMP files before it starts deleting them. The progress message shows the actual total even when cleanup starts before the screenshot browser has been opened. The completion message includes the number removed.

Thanks to @Nikonist for reporting the issue.

Testing

The native regression starts cleanup directly with 15 screenshots and verifies the initial count, that the total stays fixed as files are removed, and that cleanup leaves other files alone. Application and Recovery builds and package validation passed for both models. The screenshot regression was tested on the host.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.1 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

bd51d431dfbf4163a9cd1b2e6e195327771f67dafbad9e154987d2369b1feb7b  OpenOSC-Firmware-ZT703S.OSC
06832dd839a67a854297e52a83d37d9959509f0cc2f59972d8d78b68e264137c  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.1

Choose a tag to compare

@bve bve released this 23 Nov 00:48

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Automatic CH1 interleaving on the ZT703S (#101)

Choose Auto: CH1, 10/25 ns under Settings → Device → Performance → Interleave CH1. Auto follows the MKR enable rule. It uses both ADCs for CH1 at 10 or 25 ns/div with CH2 disabled, on the 200/100 and 280/140 performance profiles.

This keeps single-ADC acquisition at 50 and 20 µs/div. On the 280/140 profile it avoids the jump to 280 MS/s at 20 µs/div that made the noise more pronounced in #101. Select Auto explicitly after updating if you currently use On. Off remains the ZT703S default, and On still allows interleaving on other timebases. SCPI can select the mode with ACQ:INT AUTO.

Thanks to @Nikonist for the report and for comparing the same signal with interleaving disabled.

Testing

Installed 0.21.1 through Recovery on a ZT703S and verified the running version over SCPI. Hardware checks covered Auto at 10 and 25 ns/div, the transition at 50 and 20 µs/div, CH2 blocking interleave, and a 65,536-point waveform read over USB. Both models' firmware and Recovery builds, native capture and settings regressions, and stack-budget checks passed.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.21.0 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

01798916f690eb177fe920bec414fea57368eeb4494af49fa83c35784c3e496d  OpenOSC-Firmware-ZT703S.OSC
f01df504321b2ab0958488bd6807eab2b88434f30099b8bf6923dfc6f3e5a5b1  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.21.0

Choose a tag to compare

@bve bve released this 22 Nov 23:38

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Redesigned oscilloscope controls (#37, #95, #96)

  • F1 hold opens the probe ratio picker for the selected channel.
  • F2 hold resets zoom and pan and centers the channel zero levels by default. Choose Reset zoom & pan in Settings to keep the channel zero positions.
  • F3 first selects Trigger. Further taps cycle Auto → Normal → Single. Hold F3 for the 50% trigger level. Use MENU from Trigger to choose the source.
  • F4 hold opens Cursor settings by default. You can choose Measurements, Acquisition, Record memory, or Interleave CH1 where available.
  • AUTO now starts Auto Setup with a tap in the default Quick mapping. Hold it for two seconds to open Zoom & Pan. Choose Classic in Settings → Display → Scope shortcuts to tap for reset pan and hold for Auto Setup.

A tap during Auto Setup cancels it and restores the previous acquisition and any held record. Zoom & Pan changes the visible window without changing the acquisition timebase. In HOLD you can inspect the record and return to the working view when you resume acquisition.

Please test the redesigned controls. Try the AUTO tap and hold, switching back to the Trigger card, and zooming and panning a held record. If you use a different workflow, try the shortcut choices too. Please share your device model, which controls you tried, and what worked or was confusing. Oscilloscope controls on the Wiki · Scope shortcuts · Leave feedback in Discussions

10000:1 probe preset (#97)

Both channels can use the 10000:1 probe preset. The Position card shows X10K. The preset scales voltage readouts for a matching probe. The hardware input limits still apply.

Thanks to @Nikonist and @taylora1-1 for working through the control mapping and use cases.

Testing

Installed 0.21.0 through Recovery on a ZT703S and verified the running version over SCPI. Hardware checks covered the revised trigger workflow, channel selection and the probe picker, Auto Setup cancellation, zoom and pan in RUN and HOLD, and shortcut navigation. Both models' firmware and Recovery builds, native control regressions, and stack-budget checks passed.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.20.3 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
  • On the ZT703S, CH1 interleave applies DC offset correction by default. Run Interleave gain & timing to calibrate gain and timing for the unit.

SHA-256

51355c62afc2498f4d2947275b54fa8d03d8380c304da740f74c7f7494278994  OpenOSC-Firmware-ZT703S.OSC
ceb725d88249b2ccb2b17c8780a1a28a946fe56a4f6ea875e89510bbb0bb208a  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.20.3

Choose a tag to compare

@bve bve released this 22 Nov 22:18

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Waveform density (#85)

Open Channel → Density for either channel in Y–T or Y–T+FFT. Colors marks less frequent paths in cooler colors and more frequent paths in warmer colors. Mono uses brightness in a selectable color. Density defaults to Off.

Use Analyze → Display → History → Persistence to set the history length. Density uses a one-second history when persistence is off. Infinite keeps observed paths, including rare events, until you clear history or change acquisition settings that reset it. HOLD freezes the display.

Scope digital gain steps (#98)

Each channel now steps from 1% through 25%, 50%, 75%, and 100% and continues in steps of 25 percentage points. An older off-grid value moves to the next step in the direction of the adjustment. The positive minimum keeps the volts-per-division scale defined.

Thanks to @Nikonist for the feature request and the digital gain report.

Testing

Installed 0.20.3 through Recovery on a ZT703S and confirmed the running version over SCPI. Also checked finite fading, Infinite retention of an occasional pulse through 272 ordinary acquisitions, the frozen HOLD display, and a return to exactly 100% gain on both channels. Both models' firmware and Recovery builds, native scope regression tests, and stack-budget checks passed.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Both Recovery packages match 0.20.2 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
  • On the ZT703S, CH1 interleave applies DC offset correction by default. Run Interleave gain & timing to calibrate gain and timing for the unit.

SHA-256

aa7497302987083372fa10aba11ec6a28de8fd1e5539fec8948093f77787177a  OpenOSC-Firmware-ZT703S.OSC
886d5588c234d1138ca83dad4f64787b774e80a6e1b59916255debd27cd94944  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK

OpenOSC 0.20.2

Choose a tag to compare

@bve bve released this 22 Nov 20:08

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.

What's new

Bode Analyzer coupling (#87)

The sweep sets both channels to AC coupling automatically. The scope restores the original coupling for each channel when the sweep completes, stops, or closes.

USBTMC with ngscopeclient (#91)

USBTMC now accepts large host read limits and returns the available reply. This fixes the stalled reads reported when adding a ZT703S in ngscopeclient over Linux USBTMC.

Scope V/div in Normal and Single (#93)

F1 Up/Down steps through the selected channel's standard range ladder. The held trace redraws at the selected scale while keeping its sample data. RUN uses the selected range for the new capture. When WAIT still shows an older trace, the F1 title shows the next range and the value row shows the plotted scale.

If an earlier version saved a digital gain setting that makes the scale look unexpected, set the affected channel's digital gain to 100% under Analyze → Display → View.

Consecutive screenshots (#94)

The confirmation reads Image saved as SCR00001.BMP using the saved file's name. The previous confirmation is cleared before the next screenshot is captured.

Boot credits

Added DivingDuck to the donors list. Thanks to @taylora1-1, @mb340, and @Nikonist for the reports and test details.

Testing

Installed 0.20.2 through Recovery on the ZT703S and verified the running version over SCPI. On the ZT703S, verified automatic AC coupling and restoration, large USBTMC reads and waveform transfer, F1 V/div changes in Normal and Single, and three consecutive BMP files. Both models' firmware and Recovery packages, native regression tests, and stack-budget checks passed.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • Recovery packages are byte-for-byte identical to those in 0.20.1. For this update, keep your installed Recovery if it is already at that version.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows No record to move. Completed records can be panned in HOLD.
  • Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
  • On the ZT703S, CH1 interleave applies DC offset correction by default. Run Interleave gain & timing to calibrate gain and timing for the unit.

SHA-256

b93d1bc713cca6a59184906dbe458a73130adb7994cfa9047077c44ef24b32e7  OpenOSC-Firmware-ZT703S.OSC
b5f5f09373a0ccb0ada4d7436691ce6d97da8358bc96e1e9b0435fad4e001b45  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK