What's new

Lossless screenshot saving

Hold HOLD/SAVE to save a 320 × 240 PNG. A scope screenshot on the ZT703S took 14.3 KiB of storage, down from 150.1 KiB for a BMP. The built-in viewer opens both formats. Over SCPI, use MMEM:CAT? "SCREENSHOTS" and MMEM:DATA? to retrieve saved files, and DISP:DATA? or HCOP:DATA? for a live BMP. Issue #161

Multimeter reading

The on-screen multimeter reading now drops redundant leading zeroes and keeps the zero before the decimal point for values below one. Thanks to @hadi-syafiq for the fix. Issue #157 · PR #159

Startup credits

Updated the contributors list shown on the startup screen.

Testing

The application and Recovery builds passed for both models. On a ZT703S, checked screenshot saving, download over SCPI, and exact RGB565 pixel reproduction in the viewer for both a new PNG and an older BMP. Native tests covered multi-chunk PNGs, corrupt data, cancellation, and multimeter and SCPI behavior.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to enter Recovery. Copy the matching .OSC to /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the file, and confirm. After the update, select START APPLICATION.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • The PNG encoder shares temporary acquisition memory with Auto Setup. Saving can be temporarily unavailable while that memory is in use.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
  • Continuous waveform-envelope transfers scan the entire record and can reduce the update rate with deep memory. For fresh frames at slow timebases, set the host's timeout to more than the configured record duration plus one second.
  • CH1 interleaving is experimental on ZT703S. Running both ADCs at 280 MS/s can add noise. Offset, gain and timing calibration are available on-device.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • A single-slot capture can reuse the previous record's memory. If that happens while waiting for a trigger, panning becomes available again when a new record arrives.
  • Settings are saved on orderly power-off, restart or entry into Recovery. Unexpected power loss can discard changes made since the last save.

SHA-256

265a9373986eee7c74631efff7914d83b4512254cc80354775b8f6b4d1157952  OpenOSC-Firmware-ZT703S.OSC
e2d9bbf46a06d686f28d53bafe9c267c629e1edcaa3d2ab80379885a10723678  OpenOSC-Firmware-ZT706S.OSC
a9b9a8c120b0a045fc14ed698d75bc3b826242c7a816dfe6112c5606d8ff5113  OpenOSC-Recovery-ZT703S.ZTK
51ed387d80c88c9d36bf34b495b3cef10c90b1cea03c7eb55bed55dc3aa151cc  OpenOSC-Recovery-ZT706S.ZTK