What's new

High-contrast menus

Select Settings → Display → Menu contrast → High contrast for a black background, white text and an outlined selection. The setting applies to instrument menus, choice lists and the screenshot browser. Theme remains the default. Issue #44 · Settings guide

RS-485 and DMX512 decoding

Select RS-485 or DMX512 in Analyze → Decoder → Protocol. Decode the CH1−CH2 difference or the logic output of a receiver on one input. RS-485 supports UART framing and baud detection. DMX512 shows the start code, up to 512 numbered data slots, BREAK and mark-after-break timing, and framing errors. Via SCPI, the protocol names are RS485 and DMX512. DMX512 exports CSV v3 with four additional fields. The other protocols retain CSV v2. Issue #163 · Wiring and settings

Testing

Firmware and Recovery builds passed for both models. Hardware testing on a ZT703S covered both menu palettes and RS-485 and DMX512 decoding, with differential test signals from an RP2040 and CSV export. Earlier runs also checked reversed polarity and recovery after a DMX512 framing error. A full 512-slot packet was checked in the host tests. Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model. The Recovery images are byte-for-byte identical to those in 0.21.17.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to enter Recovery. Copy the matching .OSC to /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the file and confirm. After the update, select START APPLICATION.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • The PNG encoder shares temporary acquisition memory with Auto Setup. Saving can be temporarily unavailable while that memory is in use.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
  • Continuous waveform-envelope transfers scan the entire record and can reduce the update rate with deep memory. For fresh frames at slow timebases, set the host's timeout to more than the configured record duration plus one second.
  • CH1 interleaving is experimental on ZT703S. Running both ADCs at 280 MS/s can add noise. Offset, gain and timing calibration are available on-device.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • A single-slot capture can reuse the previous record's memory. If that happens while waiting for a trigger, panning becomes available again when a new record arrives.
  • Settings are saved on orderly power-off, restart or entry into Recovery. Unexpected power loss can discard changes made since the last save.

SHA-256

eeddff0f08a9461ffb54735c397f2be48adba1f8dd588111d651a8f9e47774c8  OpenOSC-Firmware-ZT703S.OSC
25c6ed1f97fcb1233381a561a594d78ce55031b965b1266c291496e3a18ec9e6  OpenOSC-Firmware-ZT706S.OSC
a9b9a8c120b0a045fc14ed698d75bc3b826242c7a816dfe6112c5606d8ff5113  OpenOSC-Recovery-ZT703S.ZTK
51ed387d80c88c9d36bf34b495b3cef10c90b1cea03c7eb55bed55dc3aa151cc  OpenOSC-Recovery-ZT706S.ZTK