Skip to content

OpenOSC 0.21.7

Latest

Choose a tag to compare

@bve bve released this 24 Nov 02:45

Warning

Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. Return to the stock firmware.

What's new

Roll waveform stability

Completed waveform columns keep their samples as the trace scrolls. The newest column fills in from incoming samples, which prevents the stored part of the trace from flickering at slow timebases.

Bode markers and saved setup

  • The plot marks f1 and f2 on either side of a band-pass peak or a notch when the sweep covers both crossings. It also marks the peak or notch itself. The notch cutoffs use the passband level on each side. #122
  • Bode sweep settings, including the frequency range, point density, settling time, averages, and drive settings, are retained across an orderly power-off or restart. #124

Thanks to @taylora1-1 for the reports and the filter examples.

Trigger and cursor controls

  • With the Trigger card selected, Left and Right adjust the pretrigger from 0% to 100%. Each press changes it by one percentage point, and each held repeat changes it by five. Hold F3 to set pretrigger to 50% and place the trigger level at the midpoint of a completed signal capture. Use F2 to pan. Changes in HOLD or after a completed Single take effect on the next acquisition. #123
  • After returning from Cursor settings opened by holding F4, the first enabled cursor is selected automatically. The arrows move Time A, or Level A when only voltage cursors are enabled. #125

Thanks to @TzOk83 and @taylora1-1 for the control suggestions.

Boot credits

Added Fyfar to the donors list. Thank you for supporting the project.

Testing

The firmware and Recovery built for both models. Host tests covered Bode cutoffs for band-pass and twin-T notch data, saved sweep settings, trigger controls, cursor navigation, Roll rendering, and firmware update validation. On the ZT703S bench, the fixes were checked for stable Roll history, Bode setup after a restart, the trigger position in captured data, HOLD and Single, and movement of both types of cursor.

Full changelog

Files

Device Recovery bootloader Firmware
ZT703S OpenOSC-Recovery-ZT703S.ZTK OpenOSC-Firmware-ZT703S.OSC
ZT706S OpenOSC-Recovery-ZT706S.ZTK OpenOSC-Firmware-ZT706S.OSC

Download the files for your model.

Updating

  • From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching .OSC file into /openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION.
  • The Recovery packages match 0.21.6 byte for byte. If Recovery is already installed, update the firmware alone.
  • From 0.2.0 or older, or for a new installation — Follow the installation instructions.

Known issues

  • CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
  • Dense two-channel captures with waveform density enabled can reduce the display frame rate.
  • In single-slot configurations, an armed capture can reuse the previous record's memory. In WAIT, panning is unavailable until a new record is captured. Completed records can be panned in HOLD.
  • Settings are saved at an orderly power-off, restart or Recovery entry. An unexpected power loss can discard settings changes made since the last save.
  • USB data requires the 200/100 performance profile. USB hubs can cause disconnects.

SHA-256

f667fe75d231543195a68885bf2f98354de8f6c0bfb50e4e3c8355b3b42c949f  OpenOSC-Firmware-ZT703S.OSC
4b681a4105c8b10a467c7d004093d2e15399ecdbb5907d0a43f94568b3f59140  OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81  OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2  OpenOSC-Recovery-ZT706S.ZTK