Repository navigation
Releases
v1.4.0
What's Changed
- feat(ui): settings layout — interfaces in CCU connection, collapsible advanced cards (1.2.1-beta.0) by @california444 in #44
- fix(battery): no percentage without voltage, battery for push buttons (1.2.1-beta.1) by @california444 in #45
- CCU mock: MASTER paramsets, putParamset, set point limits by @california444 in #47
- Heating groups (#42) by @california444 in #46
- MASTER paramsets: thermostat range and Off, battery scale, input operating mode by @california444 in #48
- CCU mock: CONFIG_PENDING after MASTER changes on groups by @california444 in #49
- HmIP thermostats: Off / Heat as one putParamset by @california444 in #50
- Thermostat: Heat after Off restores a minimum chosen in Home by @california444 in #51
- Tests: never reach a CCU port by @california444 in #52
- Thermostat: while Off, Home keeps the temperature Heat restores by @california444 in #53
- Release 1.4.0-beta.3 by @california444 in #54
- Drop references to the local planning notes by @california444 in #55
- chore(deps-dev): bump the dev group with 2 updates by @dependabot[bot] in #56
- Release 1.4.0 by @california444 in #57
Full Changelog: v1.2.0...v1.4.0
v1.4.0-beta.3
What's Changed
- CCU mock: MASTER paramsets, putParamset, set point limits by @california444 in #47
- Heating groups (#42) by @california444 in #46
- MASTER paramsets: thermostat range and Off, battery scale, input operating mode by @california444 in #48
- CCU mock: CONFIG_PENDING after MASTER changes on groups by @california444 in #49
- HmIP thermostats: Off / Heat as one putParamset by @california444 in #50
- Thermostat: Heat after Off restores a minimum chosen in Home by @california444 in #51
- Tests: never reach a CCU port by @california444 in #52
- Thermostat: while Off, Home keeps the temperature Heat restores by @california444 in #53
- Release 1.4.0-beta.3 by @california444 in #54
Full Changelog: v1.3.0-beta.5...v1.4.0-beta.3
v1.4.0-beta.2
Beta of 1.4.0.
Changes since 1.4.0-beta.1:
- Thermostat: Heat after Off restores a minimum chosen in Home. Before, a device with a 5 °C minimum went back to an earlier, higher temperature (#51).
v1.4.0-beta.1
v1.4.0-beta.0
Beta of 1.4.0. Contains everything from main, including heating groups (#42, #46) and MASTER paramsets (#48).
- Thermostat: The target temperature range comes from the device settings in the CCU (TEMPERATURE_MINIMUM / TEMPERATURE_MAXIMUM). Off stays Off on devices whose minimum is above 4.5 °C (HmIP-eTRV-B / HmIP-WTH-2 report 5 °C after Off, #42). 4.5 °C counts as Off in every mode.
- Battery: The percentage scale comes from LOW_BAT_LIMIT (0 % at the limit, 100 % at limit / 0.75).
- Input channels: The operating mode in the CCU (key / switch / binary / inactive) is respected. The UI offers only fitting services and doorbell triggers, and the log warns on mismatches.
- UI: The Save button below the settings is enabled after channel changes, so the child bridge restart can be started from there. The UI server writes no log line per request.
v1.3.0-beta.5
Beta of 1.3.0 (heating groups, #42).
Changes since beta.4:
- Beta diagnostics (
[group-diag]log lines) removed. - UI: the Save button below the settings is enabled after a saved channel change, so the child bridge restart can be started from there.
- UI server: no boot banner and no log line per request.
- README: heating group and both thermostats in the tested devices list.
v1.3.0-beta.4
Beta from branch feat/heating-groups for testing heating groups (#42). Not merged into main yet.
Changes since v1.3.0-beta.3:
- Plugin UI: "Show humidity" is offered only for channels that have a humidity datapoint (asked from the CCU when the editor opens); radiator thermostats no longer offer it.
- Plugin UI: Save button next to the tabs while settings are unsaved (the Homebridge Save button below the page is often out of view). The Homebridge Save button is disabled while nothing is unsaved.
- Plugin UI: "Use TLS" is a plain checkbox aligned with the inputs; the TLS ports are listed under XML-RPC ports. Interface labels stay on one line.
- Plugin UI: the channel list shows all discovered channels by default; the help box moved below the list.
- Debug log: no more lines for opening and closing each CCU callback connection; only broken ones are logged.
v1.3.0-beta.3
Beta from branch feat/heating-groups for testing heating groups (#42). Not merged into main yet. Replaces v1.3.0-beta.2, which was never published to npm (formatting check failed).
Changes since v1.3.0-beta.1:
- Thermostat option
showHumidityonly applies to channels with a humidity datapoint (paramset description). Radiator thermostats (HmIP-eTRV-*, HM-CC-RT-DN) no longer show "No Response" for humidity; the plugin logs once that the option is ignored. - A failed read in debug mode names the characteristic (
get Current Relative Humidity: …instead ofget: …).
v1.3.0-beta.1
Beta from branch feat/heating-groups for testing heating groups (#42). Not merged into main yet.
Changes since v1.3.0-beta.0:
- Beta diagnostics for heating groups: every write to a group, the events that follow (with delay), a read-back after 3 s, the VirtualDevices init duration and the start values (getValue next to getParamset, mode, humidity), each log line marked
[group-diag]. Please attachgrep group-diagfrom the Homebridge log to #42. - Docs: README section "Heating groups", docs/DEVICES.md (VirtualDevices keys, group types, option
showHumidity).
v1.3.0-beta.0
Beta from branch feat/heating-groups for testing heating groups (#42). Not merged into main yet.
- VirtualDevices interface (heating groups, port 9292 / TLS 49292, path
/groups), off by default (interfaces.virtualDevices) - Heating groups as one thermostat (HmIP-HEATING, HM-CC-VG-1); plugin UI offers only channel 1 and points to the group name in the CCU
- Thermostat option
showHumidity(off by default) - Group battery reports "normal" until a LOW_BAT value arrives
- Without SET_POINT_MODE the set point decides Off / Heat