v2.2.0
Everything since 2.0.0, in one stable release. Upgrading from 2.0.0 keeps your entities, their IDs and history; the IP set under Configure is moved to its new place automatically.
Setup
- Automatic discovery: Tesy convectors on the network show up under Settings → Devices & services (DHCP). Manual add by IP still works.
- MAC address as identity: a new IP is picked up automatically, no DHCP reservation needed. The MAC is learned once from older entries.
- Configure explains every field. Optional room temperature sensor for the thermostat card.
Optional MyTESY cloud telemetry (read-only)
Add the MyTESY login of the account the convector is registered to under Configure. Nothing is ever sent to the cloud. One login can be shared by several convectors.
- Heating / idle on the thermostat card (changes within 1–3 s of the real switch).
- The convector's own temperature (0.5 °C steps) as a sensor and climate attribute; it becomes the current temperature when no room sensor is set.
- Model and firmware on the device page.
- Power and Energy (kWh, Energy dashboard ready): heating time × wattage — the MyTESY app value, or Power while heating from Configure for a measured figure (a 2000 W CN 052 measured ~1,900 W). Estimates, like the Tesy app.
- Without a working login the integration is local-only, exactly as before.
Entities and UI
- Temperature correction as a slider (−4…+4 °C; phone number pads often lack a minus key).
- AirSafe (UV) switch moved under Configuration (only AS models have the UV LEDs).
- New installs: Delayed start (switch and numbers), the cloud Heating sensor and Power are disabled by default to keep dashboards short. The firmware copies the target into the delayed-start temperature, so that number changed with every target change.
- Device link (Visit) opens www.mytesy.com instead of the convector's "use POST" page.
- Brand icon and logo.
Other
- Diagnostics download, with secrets masked (including the convector's access-point password).
- hassfest and HACS validation run on every change.
- README: tested and likely-supported models, local vs cloud data, local API notes (whole-degree settings, correction range, JSON content type).
Tested on a Tesy CN 052 200 EI CLOUD W F (firmware 4.79, MyTESY code cn05uv). Likely to work: FinEco Cloud CN 06, LivEco Cloud CN 051/052, HeatEco Cloud CN 031 — reports welcome, ideally with diagnostics.
v2.2.0b9
- The device page's link (Visit) opens the MyTESY website instead of the convector's own web page, which only answers "use POST". Deep links into MyTESY give 404, so it opens the site root.
- Includes b8 (Power while heating option).
v2.2.0b8
- Configure: optional Power while heating (W). Power and Energy use it when set; empty = the wattage from the MyTESY app (shown in the form). Attributes
power_used_w,power_source,power_in_mytesy_app_w. - Measured on a CN 052 200 (2000 W label) with a whole-home meter: ~1,900 W, as in the manual (1.91 kW).
- Includes b6/b7 (cloud model/firmware, Power/Energy, AirSafe (UV) under Configuration).
v2.2.0b7
- UV switch renamed AirSafe (UV) and moved under Configuration on the device page (set once, left on). Only AirSafe (AS) models have the UVA LEDs; others ignore it.
- Includes 2.2.0b6 (cloud model/firmware, Power and Energy sensors).
v2.2.0b6
With a MyTESY cloud login:
- Device page shows the model (e.g. CN06AS) and firmware from MyTESY.
- New Power sensor: the wattage set in the MyTESY app while heating, else 0 W.
- New Energy sensor (kWh, Energy dashboard ready): heating time × that wattage. Estimates, like the Tesy app. Pauses while the cloud is down. Tesy's own hourly heating seconds shown as attributes for comparison.
Without a working cloud login none of this is available; local control is unchanged.
Also: diagnostics now mask the convector's access-point password; hassfest + HACS validation in CI; README lists likely-supported models.
v2.2.0b5
- Climate shows heating / idle (HVAC action) from MyTESY cloud telemetry.
- Convector's own temperature (0.5 °C steps) as climate attribute
internal_temperature; used as current temperature when no room sensor is set. - Includes 2.2.0b4: temperature correction as a slider.
- Without a cloud login nothing changes.
v2.2.0b4
v2.2.0b3 (beta): readable icon
Uses the MyTESY app mark as the integration icon and adds a dark-mode logo.
v2.2.0b2 (beta): icon
Adds the integration icon and logo (shown in HA 2026.3+). DHCP discovery confirmed working on a CN06AS.
v2.2.0b12
- New installs: the two delayed-start numbers (temperature, delay) are disabled by default too. The firmware copies the target temperature into the delayed-start temperature, so it changed with every target change.
- README: local vs cloud data table (no Wi-Fi signal in either).
- Includes b10/b11.