Repository navigation
Everything since 2.0.0, in one stable release. Upgrading from 2.0.0 keeps your entities, their IDs and history; the IP set under Configure is moved to its new place automatically.
Setup
- Automatic discovery: Tesy convectors on the network show up under Settings → Devices & services (DHCP). Manual add by IP still works.
- MAC address as identity: a new IP is picked up automatically, no DHCP reservation needed. The MAC is learned once from older entries.
- Configure explains every field. Optional room temperature sensor for the thermostat card.
Optional MyTESY cloud telemetry (read-only)
Add the MyTESY login of the account the convector is registered to under Configure. Nothing is ever sent to the cloud. One login can be shared by several convectors.
- Heating / idle on the thermostat card (changes within 1–3 s of the real switch).
- The convector's own temperature (0.5 °C steps) as a sensor and climate attribute; it becomes the current temperature when no room sensor is set.
- Model and firmware on the device page.
- Power and Energy (kWh, Energy dashboard ready): heating time × wattage — the MyTESY app value, or Power while heating from Configure for a measured figure (a 2000 W CN 052 measured ~1,900 W). Estimates, like the Tesy app.
- Without a working login the integration is local-only, exactly as before.
Entities and UI
- Temperature correction as a slider (−4…+4 °C; phone number pads often lack a minus key).
- AirSafe (UV) switch moved under Configuration (only AS models have the UV LEDs).
- New installs: Delayed start (switch and numbers), the cloud Heating sensor and Power are disabled by default to keep dashboards short. The firmware copies the target into the delayed-start temperature, so that number changed with every target change.
- Device link (Visit) opens www.mytesy.com instead of the convector's "use POST" page.
- Brand icon and logo.
Other
- Diagnostics download, with secrets masked (including the convector's access-point password).
- hassfest and HACS validation run on every change.
- README: tested and likely-supported models, local vs cloud data, local API notes (whole-degree settings, correction range, JSON content type).
Tested on a Tesy CN 052 200 EI CLOUD W F (firmware 4.79, MyTESY code cn05uv). Likely to work: FinEco Cloud CN 06, LivEco Cloud CN 051/052, HeatEco Cloud CN 031 — reports welcome, ideally with diagnostics.