0.44.0: who makes what in a kit manual

Choose a tag to compare

@dundysm dundysm released this 16 Nov 11:41

the guide now says who makes a kit's reagents; tested on an eighteenth set from outside: eight manuals from five makers (promega, thermo fisher, cell biolabs, biovision, sciencell), each drafted five ways by five agents at once

  • result: 38 of 40 drafts reach a rehearsed protocol, 37 at the first attempt, and the 38 do the manual's assay; 2 were handed back to a person (a 100-assay kit asked to fill 162 wells)
  • guide: what the reagent preparation makes is a person's, before the run; standards, sample dilutions and what the numbered steps make are the robot's
  • guide, after the write-up: a mix a numbered step makes is the robot's also when the text wants it fresh; a kit's contents list is not what stands on the deck, and a run that needs more than one kit says how many; wells asked for only under a condition are left out; a sample range made up to a total is half the total; an amount too small to pipette is diluted on the deck first
  • after the fixes, the five manuals they touched were drafted again all five ways (not an outside test): 25 of 25 pass at the first attempt
  • my mistake in this set: two sheets were registered with one page of two; the ten drafts from the cut text are void and were redone from the whole text
  • totals: 232 of 267 drafts from 108 manuals stand as rehearsed programs with no hand edits; 218 tests
  • caveats: five agents agreeing is one reading of one text, not five tests; nobody who has run these kits has read the drafts; details in evals/RESULTS.md

0.43.0: eight manuals drafted five ways

Choose a tag to compare

@dundysm dundysm released this 16 Nov 02:54

the widest test so far: eight kit manuals of different kinds, each drafted for the Flex, the OT-2 and the Hamilton with nothing decided, and for the Hamilton and the Flex with 24 samples in triplicate; forty drafts, by five agents at once

  • result: all 40 reach a rehearsed protocol, 34 at the first attempt; 31 do the manual's assay; 9 did only its first half, because a rule of the guide cut two assays in two
  • guide: alternatives (plate reader or flow cytometry) take the first; stages of one assay (a reaction and the ELISA that reads it) are written in full; culture over days happens before the run; a timed incubation at 37 C is a pause, however short
  • guide: how much a deck holds (19 plates and troughs on the Hamilton, 9 on an Opentrons deck, each checked against its planner); when the samples need more, the file is written for as many whole plates as fit and says how many runs that makes
  • check: a step that empties a range passes over wells that hold nothing, as long as another well of the step holds some; that one case cost six second rounds
  • after the fixes, the three kits they touched were drafted again all five ways (not an outside test): 15 of 15 pass at the first attempt, and all write the whole assay
  • totals: 194 of 227 drafts from 100 manuals stand as rehearsed programs with no hand edits; 217 tests
  • caveats: one maker; five agents agreeing is one reading of one text, not five tests; nobody who has run these kits has read the drafts; details in evals/RESULTS.md

0.42.0: one step over several ranges or plates

Choose a tag to compare

@dundysm dundysm released this 16 Nov 01:57

wherever a protocol asks for wells it now takes a list of wells and ranges, in the order written: [plate_1/A1:D6, plate_2/A1:D2]; a wash of three plates is one step, and 8 wells of a 12-well plate are one line

  • format: lists of wells for liquids, transfers and mixes; no well twice in a list; a dilution series still starts from one range
  • examples: cell_staining.yaml, fixing and staining cells on two 24-well plates; plans for all three robots
  • intake: a rehearsal problem names the step of the file it is about, and for liquid that is thrown away it offers a lower draw height; the Hamilton's deck refusal says when the plates alone fill the deck
  • measured on a sixteenth set (four staining kits from ScienCell, Cosmo Bio and Wako): 4 of 8 drafts reach a rehearsed protocol (Flex 3 of 4, Hamilton 1 of 4); every draft that needed a list wrote one step over it
  • the four handed back: two because 72 wells on 6- and 24-well plates do not fit a STARlet deck (my test sentence, not the format), two because a 1 mm layer of stain could not be taken off from the surface and the feedback did not say how; with the new feedback that kit passes on both robots in the second round
  • totals: 154 of 187 drafts from 92 manuals stand as rehearsed programs with no hand edits; 215 tests
  • details and caveats in evals/RESULTS.md

0.41.0: defaults for small plates, measured on five staining kits

Choose a tag to compare

@dundysm dundysm released this 15 Nov 19:56

the guide's defaults were written for 96 wells; three of them now cover plates with fewer than eight rows, and a fifteenth set tests them on kits from five makers

  • guide: 8 samples go from A1 down each column in turn, or as many as the plate holds; a choice the text leaves between two ("in duplicate or triplicate") takes the first; liquid already in a well is what the text gives per well, else 500 uL, 1 mL or 2 mL by plate size; a volume worked out from a ratio is listed under chose
  • measured on a fifteenth set (senescence and Oil Red O staining kits from Cayman, BioVision, Cell Biolabs, Abcam and Cosmo Bio, on 6-, 12- and 24-well plates): 7 of 10 drafts reach a rehearsed protocol on the Flex and the Hamilton, 5 at the first attempt; 3 were handed back to a person
  • one of those three and both second rounds were the guide's, and are fixed: how much a text says to make or have ready ("prepare 3 ml per well") is not the amount on the deck, and a pause is under 200 characters; the two Flex drafts pass at the first attempt when done again
  • totals: 150 of 179 drafts from 88 manuals stand as rehearsed programs with no hand edits; 209 tests
  • caveats: staining kits are one kind of protocol; 8 wells on a 12-well plate are two ranges, so every step is written twice (next); details in evals/RESULTS.md

0.40.0: small plates on an Opentrons deck

Choose a tag to compare

@dundysm dundysm released this 15 Nov 18:41

6-, 12-, 24- and 48-well plates can now stand on a Flex or an OT-2; they were left out because Opentrons marks their spacing as irregular, but they are pipetted one well at a time, where spacing does not matter

  • opentrons: five plates with fewer than eight rows are on the list (51 plates and reservoirs now)
  • the four corning costar plates are the same product as the Hamilton's, so one file that names them plans for all three robots; a test compares every well
  • measured on a fourteenth set of one (oxidized LDL uptake, microscopy protocol on a 24-well plate): passes at the first attempt on the Flex, the OT-2 and the Hamilton; the apoptosis kit drafted again for the Opentrons robots now uses a 24-well plate, not a 96-well one
  • totals: 143 of 169 drafts from 83 manuals stand as rehearsed programs with no hand edits; 208 tests
  • caveat: one manual; 6-, 12- and 48-well plates were only run from a hand-written file; details in evals/RESULTS.md

0.39.0: take all of it

Choose a tag to compare

@dundysm dundysm released this 15 Nov 18:09

a transfer to waste can now say volume: all; steadyhand works out what each well holds when the step comes, so nobody (and no model) does the arithmetic for a removal; a well that holds nothing by then is reported with the step named

  • format: volume: all on a transfer to: waste; refused for liquid that is moved on
  • guide: removals are written with it; drawn from the surface over cells or a pellet, else from 0.5 mm
  • measured on a thirteenth set (4 cayman manuals that empty wells again and again): 8 of 8 drafts reach a rehearsed protocol at the first attempt on the Flex and the Hamilton; all 46 removals use volume: all
  • totals: 140 of 166 drafts from 82 manuals stand as rehearsed programs with no hand edits
  • caveat: all is what the model of the well holds, not a sensed level; 4 manuals from one maker; details in evals/RESULTS.md

0.38.0: drafting for the OT-2's two pipettes, and cells put in a new medium

Choose a tag to compare

@dundysm dundysm released this 15 Nov 16:25

the OT-2 guide now says the robot holds two pipettes, with ranges taken from the planner's own table, so a draft keeps its mixes within what two can do; a file that still needs three is told which step ties it to each; cells put "in" a new medium have the old one taken off first, also where the text does not say so; measured on seven fresh manuals: on the first five, nine of ten drafts rehearse (Hamilton 5 of 5, OT-2 4 of 5); the tenth was refused three times because the first version of the pipette note gave a wrong range; with that corrected, two more fresh manuals and both redone ones pass at the first attempt; details in evals/RESULTS.md

0.37.1: a removal split into small draws is judged like one draw

Choose a tag to compare

@dundysm dundysm released this 15 Nov 02:43

on the OT-2 a single well is emptied by the 20 uL pipette in parts; the last part found the liquid already below the tip and failed as drawing air, where one draw of the same amount is only noted as leaving a little behind; both are noted now; found by carrying a Flex draft from the tenth set over to the OT-2

0.37.0: five assays on cells, read against their manuals

Choose a tag to compare

@dundysm dundysm released this 15 Nov 02:36

the rule behind the two wrong passes of the last set (wells the text empties are not treated as empty) is in this release, and was tried on a tenth set: five fresh manuals, all assays on cells in a plate; ten of ten drafts rehearse, eight at the first attempt; nine do what the manual asks; one adds a glucose-free treatment on top of the old medium, where the text only implies taking it off, and says so; also found: on the OT-2 a removal split into 20 uL draws fails where the same removal in one draw is only noted; details in evals/RESULTS.md

0.36.0: the rules the drafting kept tripping on, said once each

Choose a tag to compare

@dundysm dundysm released this 15 Nov 01:09

shaking and timed mixing are one rule now: a short shake is a pipette mix, also as the last step, and a long one is an incubation; a liquid no trough holds is split into named parts; every time on the magnet gets its wait, and a draw that empties a well goes down to 0.5 mm; a premix you make yourself is not made by the robot; warming to room temperature happens before the run; measured on a ninth set of five fresh manuals: ten of ten drafts rehearse at the first attempt, eight match their pages, and two add to wells the manual says to empty first (they say so in their notes; that rule is next); details in evals/RESULTS.md