Repository navigation
0.42.0: one step over several ranges or plates
wherever a protocol asks for wells it now takes a list of wells and ranges, in the order written: [plate_1/A1:D6, plate_2/A1:D2]; a wash of three plates is one step, and 8 wells of a 12-well plate are one line
- format: lists of wells for liquids, transfers and mixes; no well twice in a list; a dilution series still starts from one range
- examples:
cell_staining.yaml, fixing and staining cells on two 24-well plates; plans for all three robots - intake: a rehearsal problem names the step of the file it is about, and for liquid that is thrown away it offers a lower draw height; the Hamilton's deck refusal says when the plates alone fill the deck
- measured on a sixteenth set (four staining kits from ScienCell, Cosmo Bio and Wako): 4 of 8 drafts reach a rehearsed protocol (Flex 3 of 4, Hamilton 1 of 4); every draft that needed a list wrote one step over it
- the four handed back: two because 72 wells on 6- and 24-well plates do not fit a STARlet deck (my test sentence, not the format), two because a 1 mm layer of stain could not be taken off from the surface and the feedback did not say how; with the new feedback that kit passes on both robots in the second round
- totals: 154 of 187 drafts from 92 manuals stand as rehearsed programs with no hand edits; 215 tests