v1.12.9 — Accuracy & reliability · 40 models CI-verified
⭐ Featured — Daily Summary Tabbed dashboard
Five interactive tabs — Overview · Quality · Cycles · Duration · Events — with adaptive charts, detail popups on every element, and Dutch/English entity auto-detection.
📥 Download YAML · 📖 Full documentation · 🎨 All cards
🔧 Featured — 40 Altherma models, CI-verified
We now validate 40 Daikin Altherma model definitions against the upstream ESPAltherma project on every pull request. If a model definition ever silently drops a required attribute, our CI fails before it can break your install.
Newly tracked in this release: the HT ERRQ-ERSQ outdoor unit (11-16kW) — a high-temperature outdoor unit that publishes outdoor-side and refrigerant sensors only. Documented as a "partial model" so its limits are visible up front.
Supported model families (40 definitions)
| Family | Coverage |
|---|---|
| EBLA / EDLA D Monobloc | 4-8kW · 9-16kW |
| EPRA D / E | 14-16kW (incl. ECH2O) · 8-12kW · D7 variants |
| ERGA D / E | 04-08kW (incl. ECH2O) · D/E series |
| ERLA D | 11-16kW · 3kW (ERLA03) |
| Altherma 4 | EPSK / EPSKS / EPBX / EPSX / EPVX / EPVZ 04-14kW |
| LT Monobloc | EBLQ / EDLQ / CA series 5-16kW · Bizone variants |
| HT series | EKHBRD-ERRQ (11-16kW) + ERRQ-ERSQ outdoor unit (NEW) |
| GEO | EGSAH-X / EWSAH-X GEO3 6-10kW · EGSQH-A GEO2 10kW |
| Hybrid | Altherma Hybrid |
| Multi DHW | EKHWET-BAV3 · CKHWS-BJV3 · LT_Multi_DHWHP |
| Mini chiller | EWAA / EWYA D · EWAQ / EWYQ B |
| Protocol S | PROTOCOL_S · PROTOCOL_S_ROTEX |
Full matrix: MODEL_COMPATIBILITY.md
v1.12.9 — Accuracy & reliability
Your cycle data is now trustworthy end to end. Three quiet data-quality issues are corrected — both going forward and throughout the full history. If DHW thermal kW ever read 0.0, a single heating run showed up as two cycles, or older cycles had inflated sample counts, this release fixes all three.
🔥 DHW thermal output is real now
DHW cycles used to report 0 kW thermal output when the compressor was heating the tank. Now we measure DHW thermal directly from flow × ΔT, using the physically correct cold-side sensor (R4T — confirmed against live production captures; the previously assumed R5T overestimates by ~45%).
You'll see: realistic DHW kW in your dashboard, accurate SPF, and fewer false energy_daily_anomaly alerts.
🔗 Cleaner cycle boundaries
30–60s transient events (defrost, service routines, sensor hiccups) used to close a heating run early and start a new one. The detector now bridges transients into one continuous cycle via the new _apply_merge() primitive.
You'll see: fewer ghost cycles, duty cycle that matches real compressor behavior, and more reliable pendulum_hourly / high_cycle_rate signals.
🔧 Historical sample counts repaired
Cycles recorded before late October stored cop_sample_count values up to 10× real. A new migration (async_migrate_to_v1_12_5_sample_count_fix) repairs the whole history with a safe relative threshold (>1.5× real).
You'll see: cop_confidence ratings that match actual sample density — no more "high confidence" on 45-sample cycles.
🛡️ Safer reconfigure
_migrate_entity_ids is now idempotent — re-running it preserves unique IDs, translation keys, and history. Dashboards, automations, and history keep working after reconfigure.
🔬 Under the hood
- New
engine/physics.py— standalone Carnot COP primitive (wired in v1.13.0) - Model-compat contract: parser + checker + PR-gate + weekly drift workflow
- Deterministic CI gate: fetch-by-pinned-SHA (upstream branch movement no longer breaks the PR check)
- 130 tests in
test_model_compat.py· 8 tests intest_v1129_132_thermal_mode.py - Full suite: 3588 tests · 100.00% coverage · mypy strict 38 files
Full technical details: CHANGELOG.md
📋 Post-release watch
We're tracking the first 48 hours of v1.12.9 via #163. If you see unexpected cycle counts or DHW thermal values, please open an issue with logs — it helps us validate quickly.