🌟 What's new in v1.24.0?

Your numbers are now complete and fair, and every dashboard card got a make-over. This is a big release: please update the integration and re-paste your cards (see After updating). No breaking changes to entities or automations.

🔥 What it means for your heat pump

You now get Why it matters
Every minute of runtime counted — a heat pump that runs all day shows close to 24 hours A Home Assistant restart during a run used to drop the part before the restart (up to 11 hours a day on a 24/7 system). Runs lost earlier are rebuilt once from the stored COP measurements (#417, #419)
A fair quality score — each penalty grows with how far a run is from good A 2-minute backup-heater blip no longer costs as much as 30 minutes of backup heater. All your stored cycles are rescored once (#421)
Correct "short pause" detection and learned thresholds The pause before a run included the run itself, so Short off almost never fired (#415)
No false short runs when the heat pump switches between heating and hot water The compressor keeps running; it is now one run, not a stop and a start (#419)
Cleaner COP The old 16.5 outlier is gone from the month COP; COP below datasheet no longer fires at start-up; heating-curve advice compares readings from the same moment (#415)
Correct ΔT with the backup heater on ΔT is now measured before the backup heater, so its heat no longer inflates your ΔT (#423)
Heating-curve advice stays visible during hot water The advice pauses while the tank heats, but your measured curve stays on the cards (#427)
ESPAltherma v2 aligned with its own name catalog Values of exactly 0 or 1 are no longer lost; cooling is recognised without a hot-water tank and for "Auto Cool" (#413, #423)

⭐ The new quality score

Every closed run starts at 100. Each criterion subtracts points in proportion to how far the run is from good, up to a maximum. The Last cycle sensor shows what each criterion cost (attribute quality_penalties).

Criterion Max points How it is counted now Example Before v1.24.0
⏱️ Short run 30 30 × shortfall to the good run length good run 45 min: a 40 min run → 3.3, a 10 min run → 23.3 30 for any run under the threshold
🌡️ Low ΔT 20 20 × shortfall to the good ΔT good ΔT 5 K: 4 K → 4, 2.5 K → 10 20
⏸️ Short pause 20 20 × shortfall to the good pause good pause 20 min: 15 min → 5, 2 min → 18 20
🔁 Many short runs today 20 0 up to half the threshold, then rising to 20 at 1.5 × the threshold threshold 50 %: 25 % → 0, 50 % → 10, 75 % → 20 20
⚡ Backup heater 20 1 point per % of the run time (step 2 counts double) 2 of 300 min → 0.7, 8 of 300 min → 2.7, 30 of 300 min → 10 10, however short
❄️ Defrost 10 1 point per % of the run time above 5 % (normal defrosting is free) 6 of 300 min → 0, 30 of 300 min → 5 not counted

Not penalised: a run that continues after a heating ↔ hot-water switch, a run that is still going (Quality today waits until it ends), backup heater during a legionella cycle, and missing data. The thresholds are your own options (good run, good ΔT, good pause). Full explanation: Quality score.

Expect your scores to change: most long runs score higher, very short runs with backup heater lower. That is the new formula, not a fault.

🎨 Dashboard cards: update them too

All seven cards were checked against the data the integration really writes, in English, Dutch and French, and unified (#427):

  • Your heat pump model in every header — title + model, family, power and refrigerant.
  • Dark mode — follows the Home Assistant dark mode; every card stays readable.
  • One set of options on every card — lang_override (en / nl / fr), theme_override (auto / light / dark), show_help, in the card header. Before this release these options never reached the cards; now they work.
  • Your language everywhere — English, Dutch, French; numbers in your own format (5.27 or 5,27).
  • Fixes you will see:
    • Simple card: ΔT of the last cycle now shows (it was always "—"); Q is the real quality score.
    • Summary: no longer always Dutch; real defrost events per day.
    • Pattern analysis: the tab you tap is the tab you see.
    • Heating curve: clean points with a tooltip, a blinking live point, and the curve stays visible during hot water.
    • LWT fine-tuning: keeps your tab and pop-up when it refreshes; blue = lower, green = optimal, red = raise.
  • No longer needed: mushroom-template-card (stack-in-card, button-card and card-mod are enough).
Card YAML Docs Changelog
Simple card simple-card.yaml README CHANGELOG
COP & energy cop-energy.yaml README CHANGELOG
Summary daily-summary.yaml README CHANGELOG
Daily summary (tabbed) daily-summary-tabbed.yaml README CHANGELOG
Heating curve heating-curve.yaml README CHANGELOG
LWT fine-tuning card.yaml README CHANGELOG
Pattern analysis pattern-analysis.yaml README CHANGELOG

Settings shared by all cards (header, language, dark mode, variables): Shared card settings.

✅ After updating

  1. Update the integration: HACS → Daikin Cycle ML → Update, then restart Home Assistant. The first start runs a one-time clean-up: it rebuilds lost runs, rescores all cycles and recalculates the daily summaries. That start can take a little longer than usual.
  2. Re-paste every card you use (links in the table above): Edit dashboard → card → ⋮ → Edit in YAML, replace everything with the new YAML, Save. The old cards keep working but miss the fixes, the model header and dark mode.
  3. (Optional) Set your preferences in the card header's variables: — lang_override, theme_override, show_help. Cards now follow your Home Assistant UI language first; set lang_override: nl (or fr) if you want the integration language instead. The COP & energy card now follows the HA dark mode by default (theme_override: light keeps the old look).
  4. (Optional) Remove mushroom if no other card of yours uses it.
  5. Check: Download diagnostics → coordinator.runtime_check.coverage_pct should...
Read more

v1.23.3

Choose a tag to compare

@elRadix elRadix released this 18 Nov 22:20
143f9cf
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.23.3?

More accurate COP and backup-heater numbers, and alerts that fire when they should. No breaking changes.

  • Backup heater on its own power meter? New optional BUH power sensor (Configure → Device → Sensors). Its power is added to your heat pump meter, so COP no longer reads too high while the backup heater runs.
  • No more false "Backup heater excessive" alerts. The alert now compares backup-heater minutes with compressor minutes. Before, one long run with a few minutes of backup heater counted as a full "backup heater day".
  • Native ESPAltherma counters are kept when the integration switches to the ESPAltherma v2 entities (compressor runtime, defrosts, backup heater and starts no longer fall back to estimates).
  • "COP vs datasheet" works again with the ESPAltherma v2 entities (it stayed empty) (#388).
  • "Short run" alerts work with adaptive thresholds. If many of your runs are short, the learned threshold could drop to 2 minutes and the alert never fired. It now never goes below half of your own setting (#408).
  • Cleaner COP history. Old impossible COP readings (stored before the COP checks existed) are cleaned up once, so week/month COP no longer shows values like 0.47 or 16.5 (#408).
  • Your own COP sensor, checked. Diagnostics now compare the COP in use with the integration's measurement and ESPAltherma's estimate, so a template COP sensor that reads high is easy to spot (#408).

✅ After updating

  1. Update via HACS → Daikin Cycle ML → Update, then restart Home Assistant. The first start runs a one-time clean-up of old COP data and daily summaries (a few seconds).
  2. Backup heater on a separate meter? Configure → Device → Sensors → BUH power sensor → pick that meter.
  3. Using your own COP template sensor? Consider clearing COP sensor: the integration's own COP (your power meter + ESPAltherma heat, from one snapshot) is usually more accurate. Compare first in Download diagnostics → cop_cross_check.
  4. No card changes needed.

Found something? Open an issue and attach your diagnostics.

📚 Docs: Configuration — sensors · Alerts — buh_excessive · ML — adaptive thresholds


🛠️ Technical Details & Fixes

Added:

  • BUH power sensor - buh_power_sensor_entity (options Device → Sensors, EN/NL/FR); added to power_sensor_entity in _power_from_meter (W/kW normalised, invalid/idle ignored); compressor detection unchanged; attributes buh_power_sensor, buh_meter_w. PR #410.
  • COP cross-check - diagnostics coordinator.cop_cross_check (used / flow × ΔT ÷ power / ESPAltherma estimate / deviation %). PR #409.

Fixes:

  • AUTO source tie - when v2 wins a 12/12 tie (rule unchanged) the monolithic sensor's extra attributes are merged in (individual wins per key); source_resolution.supplemented_from_mono. PR #407.
  • #388 Datasheet normalisation - outdoor temperature via the alias layer (Outdoor air temp.(R1T) / R1T-Outdoor air temp.); last_record only exists on the closing tick. PR #407.
  • buh_excessive - ratio = BUH minutes (runtime_acc.<day>) / compressor minutes (daily_summary) over 7 d, as documented; cycle ratio kept as fallback (prod-1: 0.444 → 0.011). PR #407.
  • #408 Diagnostics follow-ups - effective short-run threshold ≥ half the configured value; migration v30 flags pre-gate COP samples (> MAX_COP, heating/DHW < COP_FLOOR) and rebuilds/deletes their cop_hourly hours; daily_summary.duration_min = within-day portion (≤ duration_max), all days re-rolled once. PR #409.

Tests: 6,774 tests, 100% coverage; new suites reproduce prod-1 v1.23.2 diagnostics (AUTO tie, normalisation without last_record, BUH ratio), the learned-threshold collapse, the v30 migration on a real database, and the BUH power sensor.

Changelog: CHANGELOG.md | Compare v1.23.2...v1.23.3



☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

v1.23.2

Choose a tag to compare

@elRadix elRadix released this 18 Nov 20:43
02b519f
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.23.2?

One more fix for heat pumps that run through the night. No breaking changes.

  • A run that is still going now shows up in the daily charts (#400). Before, a long run (for example started at 22:00 and still running at 08:00) only appeared in the per-day charts once the compressor stopped. Now its runtime shows on each day it covers while it runs, updated every 15 minutes. The Today sensors were already correct.
  • Good to know: a run is never cut at midnight. It stays one run; the integration splits its runtime over the days it covers.

✅ After updating

  1. Update via HACS → Daikin Cycle ML → Update, then restart Home Assistant.
  2. No card changes needed (if you skipped v1.23.1: re-paste Daily Summary Tabbed and Pattern Analysis from dashboard/cards/).

🙏 Thank you

  • CuttingStorm (Tweakers forum) — for the run-across-midnight report that led to this check (#400)

Found something? Open an issue and attach your diagnostics.

📚 Docs: Database — daily summary semantics


🛠️ Technical Details & Fixes

Fixes:

  • #400 Running cycle in the live rollup - cycle rows are written on close only, so the 15-min live rollup (R782) re-rolled today without the running cycle. async_rollup_day(open_cycle=...) now adds the detector's open cycle (runtime + longest within-day portion; count / quality / BUH / defrost still on close), and the live rollup rolls every day the open cycle covers (DST-safe). PR #405.

Tests: 6,722 tests, 100% coverage; new suite runs a real detector 22:00 → 03:00 through the live rollup (charts at 01:00 and after close).

Changelog: CHANGELOG.md | Compare v1.23.1...v1.23.2



☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

v1.23.1

Choose a tag to compare

@elRadix elRadix released this 18 Nov 18:23
900e048
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.23.1?

A fix release for the daily overview when your heat pump runs past midnight, fewer lost measurements, and better self-diagnosis. No breaking changes.

  • Runs past midnight no longer mess up the daily overview (#400).
    • The morning after a night run no longer shows quality 0 %. A day that only contains the tail of last night's run now shows "—".
    • "Longest run" can no longer be longer than the day's total runtime: each day now shows its own part of a run that crosses midnight.
  • Defrosts and backup heater show up in the Events tab (#400). The per-day event counts now use the same real numbers as the Today block, so they are no longer empty or 0 %.
  • No more lost COP measurements (#353). If the database is briefly busy, measurements are kept and saved a moment later instead of being dropped.
  • Lighter nightly maintenance (#353). The database is only compacted when there is actually space to reclaim.
  • Better diagnostics (#353). If an update is ever slow, the diagnostics file now shows when it happened and which step caused it.
  • All default thresholds in one place (#193). See docs/cycle-thresholds.json.

✅ After updating

  1. Update via HACS → Daikin Cycle ML → Update, then restart Home Assistant.
  2. Re-paste two dashboard cards to get the Events fix: Daily Summary Tabbed and Pattern Analysis. Copy the latest YAML from dashboard/cards/ (HACS does not update cards you pasted). Other cards need no change.

🙏 Thank you

  • CuttingStorm (Tweakers forum) — spotted the 0 % quality, "longest > total" and empty event counts after a run across midnight (#400)

Found something? Open an issue and attach your diagnostics.

📚 Docs: Database — daily summary and maintenance · Dashboard cards · Cycle thresholds


🛠️ Technical Details & Fixes

Fixes:

  • #400 Daily summary across midnight - daily_summary_recent.quality_avg is null for a row without cycles started that day; daily_summary.duration_max is the longest within-day portion (always ≤ total_duration_s); _apply_merge keeps MAX of buh_used / defrost_used / dT_max of absorbed runs; new events_by_day (BUH minutes, defrost events from runtime_acc.<day>) used by Daily Summary Tabbed Events and Pattern Analysis. PR #401.
  • #353 A3c slow tick - diagnostics coordinator_timing.tick_duration_max_ts / _tick / _phases_ms; cop samples hitting database is locked are queued (max 240) and flushed on the next insert (database.pending_cop_samples); nightly VACUUM only when ≥ 20 % pages are free, explicit run_maintenance vacuum: true always runs (database.last_vacuum). PR #402.
  • #193 Canonical thresholds - docs/cycle-thresholds.json (schema 1) with a drift test against const.py / engine/physics.py; Carnot factor 0.65. PR #403.

Tests: 6,703 tests, 100% coverage; new suites for cross-midnight daily summary (incl. Node-rendered cards), real SQLite write-lock reproduction, conditional VACUUM, slow-tick attribution and threshold drift.

Changelog: CHANGELOG.md | Compare v1.23.0...v1.23.1



☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

1.23.0

Choose a tag to compare

@elRadix elRadix released this 18 Nov 16:20
d24187e
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.23.0?

Dashboards that work in every language, more honest COP numbers, corrected Daikin datasheets, and first support for bivalent (heat pump + boiler) systems. No breaking changes.

  • Dashboards work in Dutch and French. Cards stayed empty when Home Assistant created your entities in Dutch or French (e.g. cyclus_status instead of cycle_state). Every card now finds its sensors in any language — even after you rename them. Reported in #347 and #369 — thank you @JoHuTi and @MBGek!
  • More realistic COP. Impossible readings from an external COP sensor (above 11 or infinite) are ignored, and short start-up dips below 1.0 no longer drag your averages down. COP today, weekly/monthly COP, SPF and heating-curve advice now only use trustworthy samples (#388).
  • Corrected Daikin datasheets. 24 models now use official Daikin figures (with source), including EPRA, ERGA, ERLA, EDLA, EBLA, EBLQ and the EVLQ hybrids. Hybrids no longer get a false "COP below datasheet" alert (#392).
  • Hybrid units recognised by their indoor code. EHYHBH / EHYHBX / CHYHBH / Rotex codes (e.g. EHYHBX08AAV3) map to the right EVLQ model.
  • Bivalent systems (heat pump + external boiler). Enable Bivalent Operation in ESPAltherma and the integration keeps boiler periods out of your heat-pump COP and stops false short-cycle alerts during boiler handovers (#288). Raised by @fransh47 in Discussion #176 — thank you!

✅ After updating

  1. Re-paste your dashboard cards. HACS updates the integration, not the cards you pasted. Copy the latest YAML from dashboard/cards/ into each card.
  2. Check your model (Settings → Devices & Services → Daikin Cycle ML → Reconfigure). If you picked one of these, switch to your real model — they do not exist in Daikin's range: EPRA04/06/11/14/16/18EAV3, ERLA04/06/08/12DAV3, EPGA10DAV3. Your data is kept.
  3. Bivalent or hybrid? In ESPAltherma uncomment Bivalent Operation, Boiler Operation Demand and Boiler DHW Demand — see Configuration §4.8.

🙏 Thank you

A big thank you to everyone who reported problems and shared diagnostics — this release exists because of you:

  • @JoHuTi — empty dashboards on a Dutch install (#347)
  • @MBGek — dashboards on a hybrid EVLQ08CV3, with diagnostics that also exposed the hybrid COP reference (#369)
  • @fransh47 — bivalent heat pump + gas boiler setup (Discussion #176 → #288)

Found something? Open an issue and attach your diagnostics.

📚 Docs: Troubleshooting — empty cards (§4.6) and COP guards (§5.1) · Model compatibility · Dashboard cards


🛠️ Technical Details & Fixes

Fixes:

  • #347 / #369 Dashboards empty on non-English installs - all 7 cards resolve entities via English id → entity-registry translation_key → NL/FR id; Jinja headers via integration_entities(). English output byte-identical. Pattern Analysis Dutch aliases fixed (cop_sww_*, cop_degradatie_week). PR #390.
  • #388 COP chain impossible values - cop_sensor_entity gated on finite and ≤ MAX_COP; classifier-flagged samples (is_transition_artifact=1) excluded from cop_today, hourly rollup, SPF, heating-curve advice and hybrid means; cop_normalized_a7w35 raw-attribute fallbacks. PRs #389, #391.
  • #369 Heating/DHW COP < 1.0 stored flagged via physics.below_cop_floor (Carnot classifier contract unchanged). PR #394.
  • #392 Datasheet audit - Daikin product-table values with ref + verified for 24 models; ERGA/EBLA second point relabelled A7/W55 → A7/W45; EVLQ A7/W35 nominal 5.04 / 4.45 (was 5.85 / 5.75); erga08evh7 datasheet; 11 non-catalogue models flagged verified: false (kept). PRs #393, #394.
  • #288 Bivalent support (phase 1) - boiler signals trusted when the source publishes Bivalent Operation; ERGA EVH aliases. PR #395.
  • ESPAltherma alignment - MODEL_ATTRIBUTES.json at beta b613d10; daily model-compat drift job fixed (missing label). PR #393.

Follow-ups: #397 remaining datasheet verification (EPGA, EDLQ, EBLQ011–016, EPSK, ERRQ) · #398 bivalent phase 2 (wizard, bivalent_active, boiler energy, alerts).

Tests: 6,649 tests, 100% coverage; new suites for dashboard entity resolution (Node-executed card JS, real HA template engine), datasheet audit, config-flow E2E for all 60 models, COP gate/floor and bivalent signals.

Changelog: CHANGELOG.md | Compare v1.22.10...v1.23.0



☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

v1.22.10 - Bug fixes + diagnostics hardening

Choose a tag to compare

@elRadix elRadix released this 16 Nov 23:13
91034f5
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.22.10?

A focused patch release fixing 4 bugs since v1.22.9. No breaking changes.

  • Reliable source health. source_stale no longer fires false alarms on stable weather. Tracks publish timestamp, not just value changes.
  • Ready for HA 2027. Diagnostics no longer uses deprecated device-registry APIs removed in HA 2027.9 / 2027.10.
  • Cleaner Recorder history. sensor.alerts_today attributes exceeded HA Recorder's 16 KB limit on busy days. Now size-capped in 3 tiers.
  • Visible notify health. notify_health diagnostic is now emitted. See per-service fail streaks without reading logs.

🛠️ Technical Details & Fixes

Fixes:

Changelog: CHANGELOG.md | Compare v1.22.9...v1.22.10



☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

v1.22.9 - Notification Polish & Stability

Choose a tag to compare

@elRadix elRadix released this 16 Nov 20:07
ef1e91a
Daikin Cycle ML


🌟 What's new in v1.22.9?

This release focuses on stability, cleaner logs, and a smoother dashboard experience.

  • Smarter Notifications: Missing notify services (e.g., notify.telegram) no longer flood your Home Assistant logs with tracebacks. They are now silently handled, deduped, and surfaced via a clean HA repair if they persist.
  • LWT Fine-Tuning Card: The dashboard cards, including the LWT Fine-Tuning card, continue to deliver precise heating curve advice. We've resolved background flakiness that could occasionally cause dashboard updates to stall.
  • General Polish: Cleaned up underlying test frameworks and scripts to ensure future updates deploy even faster.

🛠️ Technical Details & Fixes

Fixes:

Changelog: View the full CHANGELOG.md for a complete list of changes.


☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:

v1.22.8 — Accurate compressor runtime & smarter cold-snap advice

Choose a tag to compare

@elRadix elRadix released this 15 Nov 20:04
1e2f4e3
Daikin Cycle ML

⭐ If this project helps you, consider giving it a star. ⭐

v1.22.8 — Accurate compressor runtime & smarter cold-snap advice

⭐ If this project helps you, consider giving it a star.

What you'll notice

Your compressor runtime is finally accurate

sensor.daikin_cycle_ml_runtime_compressor_today was underreporting. It only counted completed cycles that started today — missing overnight cycle tails and the currently-running cycle.

On our reference system, the sensor showed 3.4 h when ESPAltherma reported 10.3 h.

Now: the sensor matches the firmware counter within 0.6 %. If you have a fixed-scale card for this sensor, bump the maximum to 12 h or higher.

sensor.daikin_cycle_ml_duty_cycle_today (derived from the above) also corrects: from 33 % → 99.8 % on a continuous-compressor day, with its band attribute correctly flipping to saturated.

No more "lower your setpoint" advice during cold snaps

During a cold snap, if the backup heater (BUH) is running, the system used to still advise "lower the LWT" — advice that would push BUH usage higher and reduce efficiency. A 1-hour cached analysis wasn't being invalidated when BUH kicked in.

Now: heating_curve_advice returns state=keep with reason=buh_active while BUH is running, and flips back the moment BUH stops. A new suppressed_by attribute shows exactly why.

Smoother Home Assistant

~5 % of coordinator ticks were blocking the HA Core event loop for 7–25 s, briefly starving other integrations. Root cause: a COP-analysis query running every 30 s → 5 760 DB queries/day.

Now: that query is throttled to once per minute — 50 % fewer queries, fewer slow ticks.

Sample rate is now honest

Diagnostics showed samples_last_24h: 198 vs samples_expected_24h: 2880 (looked like 6.9 %). But the system had only been up for 103 minutes — the real rate was 95.7 %.

Now: diagnostics show samples_window: since_start with sample_rate_pct: 95.7 when uptime is under a day, and samples_window: 24h once it exceeds a day.

Under the hood

Fixes you won't see but should know about:

  • Native-first counters. Whenever ESPAltherma reports a runtime counter (compressor, BUH, defrost, starts), that value now wins over our computed fallback. Every counter exposes source: native / source: computed so you always know where the number came from.
  • _read_float hardened. Firmware values of true, NaN, or inf are rejected cleanly instead of silently poisoning calculations.
  • BUH attribute leak. buh_step1_s / buh_step2_s / buh_total_s no longer appear on runtime_compressor_today (they belong on runtime_buh_today).

Do I need to do anything?

No. Auto-updates via HACS. After upgrade:

  • runtime_compressor_today corrects within ~30 s.
  • Fixed-scale cards for that sensor → bump max to 12 h or higher.
  • Historical daily_summary records are unaffected — only today's live values change.

Known open issue

The tick p95 residual (25 s max) isn't fully eliminated — the throttle removes ~50 % of the load, but some slow ticks remain. Tracking on #353. If you're on slow bind-mount storage and notice lag, please attach iostat -x 5 output to that issue.


🔧 Technical Notes

Related PRs

PR Title
#361 A3a sample-rate label + A3b cop_today throttle
#362 A3 tick metrics decision record
#363 A4 BUH excessive troubleshooting
#364 Release v1.22.8
#365 CHANGELOG sync

Issue: #353 — A1/A2/A3/A4 tracker
Design record: docs/design/a3-tick-metrics.md

Files Changed

Area File Change
Engine engine/cop_analyzer.py A2 BUH suppress
Engine engine/runtime_source.py native-first resolvers
Coordinator coordinator.py A3a _record_tick_health, A3b _refresh_cop_today
Sensor sensor.py _resolve_attrs, source attr
Storage db.py, store.py cycles_intersecting
Diagnostics diagnostics.py samples_window, sample_rate_pct
Tests tests/test_v1228_*.py new (A1/A2/A3)
Docs docs/design/a3-tick-metrics.md, README.md new

CI & Quality

  • 6 093 tests, 100 % coverage
  • Ruff: 0 errors · Mypy: clean
  • CI matrix: 9/9 green (ruff, mypy, coverage, build, HACS, Hassfest, CodeQL, guard)

Residual (A3c)

25 s max-tick origin not fully eliminated. Needs prod-1 iostat -x 5 + grep daikin_cycle_ml /home-assistant.log. Tracked on #353.


☕ Support


LWT Fine-Tuning card
NEW in v1.22.6: LWT Fine-Tuning card · Advice / Buckets / Analysis / Live · all local, all free

v1.22.7 — BUH counter fix: wall-time + native-first

Choose a tag to compare

@elRadix elRadix released this 14 Nov 07:28
134953d
Daikin Cycle ML

⭐ If this project helps you, consider giving it a star. ⭐

v1.22.7 — BUH counter fix: wall-time + native-first


🐛 What Was Wrong

runtime_buh_today was 2× too high when both BUH Step1 and Step2 were active. A prod-1 user reported 90 min of backup-heater runtime on a day the firmware counter showed 42.6 min.

Root cause: each tick added dt_s (30s) to both _buh_step1_s and _buh_step2_s, then the sensor summed them — 60s per 30s wall-time.

Related: ESPAltherma v2 exposes precise firmware counters (Stats: Backup heater today, Stats: Defrosts today, Stats: Compressor starts today) that were unused. We now prefer them with computed fallback.


✅ What Changed

Wall-time counter (core fix)

  • New _buh_total_s — max 1× dt_s per tick regardless of step1/step2
  • runtime_buh_today reads _buh_total_s instead of step1_s + step2_s
  • step1_s / step2_s kept as diagnostic detail in attrs
  • Restore migration: pre-v1.22.7 payloads (no buh_total_s) backfill via max(step1, step2)

Native-first for ESPAltherma v2

New engine/runtime_source.py with strict resolvers:

Counter Priority
BUH today Stats: Backup heater today (min) × 60 → computed
Defrosts today Stats: Defrosts today → computed
Compressor starts Stats: Compressor starts today → computed
Compressor runtime computed primary (firmware resets on reboot)

Each sensor exposes a source attribute (native / computed).

Hardening

  • Strict isinstance(attrs, dict) — reject MagicMock (float(Mock) == 1.0 false positive)
  • Safe isinstance(snap, dict) guards in sensor accessors

CI infrastructure

  • Pre-push hook skips full pytest suite on branch-deletion pushes — from 500s+ to <2s.

Not changed

  • buh_excessive alert — 7-day ratio, not today's counter
  • COP / heat / electricity today — already use power_sensor + cop_sensor
  • Defrost duration — no native field on ESPAltherma
  • Compressor runtime — computed-primary per user preference

🧪 Testing & quality

  • 5,960 tests pass, 100% coverage
  • 20 new tests in test_v1227_buh_walltime.py
  • Suite: 504s (was 528s, −4.5% via --dist worksteal)
  • Ruff clean on changed files
  • No regression — v1.22.6 FR / DAV3 / LWT card preserved

📊 Impact

User Before After
Prod-1 (v2 ESPAltherma) 5436 (90.6 min) 2556 (42.6 min), source: native
v2 with Stats: computed only firmware-exact, source: native
v1 (no Stats:) double-counted wall-time computed, source: computed

⚙️ Upgrade

No action required. Auto-updates via Marketplace (HA 2026.11+) or HACS.

After upgrade, runtime_buh_today corrects from next coordinator tick (~30s). Historical daily_summary per-cycle records unaffected.

🔗 Links


☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:


LWT Fine-Tuning card
NEW in v1.22.6: LWT Fine-Tuning card · Advice / Buckets / Analysis / Live · all local, all free

v1.22.6 — French translations, 3 new Altherma models, and a huge thank you

Choose a tag to compare

@elRadix elRadix released this 13 Nov 20:22
b408269
Daikin Cycle ML

⭐ If this project helps you, consider giving it a star. ⭐

v1.22.6 — French translations, 3 new Altherma models, and a huge thank you


🇫🇷 Full French support

Every part of the integration is now available in French:

  • Complete UI — 873 translation keys, parity with English (config_flow, options, repairs, services)
  • Notification reports — status reports, stooklijn advice, COP-low alerts
  • Alert texts — titles, labels, advice texts, severity labels, KMeans advice
  • 6 dashboard cards — Simple, Heating Curve, COP & Energie, Pattern Analysis, Daily Summary Tabbed, LWT Fine-Tuning
  • Auto-locale — picks French from hass.language=fr or notification_language=fr

🆕 3 Daikin Altherma 3 H HT models

  • EPRA14DAV3 — Altherma 3 H HT split, single-phase
  • EPRA16DAV3 — Altherma 3 H HT split, single-phase
  • EPRA18DAV3 — Altherma 3 H HT split, single-phase

All three ship with verified EN14511 datasheets from Daikin (ETVH/ETVX/ETBH/ETSH16 indoor units).


🐛 What Changed

  1. Leaving water temp. before BUH (R1T) — now consumed as thermal_power. physics.dt_from_attrs prefers compressor-side supply temp over R2T, improving ΔT accuracy on ESPAltherma v2 sources.
  2. notification_engine — accepts 'fr' in language validation (options.notification_language).
  3. Language detection — added fr branch to LWT card, Daily Summary Tabbed, and alert engine.
  4. Tests — 4 test files updated for +1 consumed attribute (21→22 operational, 25→26 consumed).
  5. New guard-test — build_rich_alert invalid-language fallback (coverage for the language='xx' path).

🧪 Testing & quality

  • ~5,926 tests pass, 100% coverage (branch + statement)
  • Ruff clean on all changed files
  • Full key parity — 873/873 French keys match English
  • No regression — v1.22.5 fixes preserved (options flow, source_stale, dhw_installed)

🙏 A huge thank you to @azsono03

This release is 90% the work of @azsono03.

He:

  • Translated the entire integration into French — 873 keys, 6 dashboard cards, all notifications
  • Contributed 3 new Daikin Altherma 3 H HT models with verified EN14511 datasheets
  • Fixed a subtle R1T-before-BUH consumption bug that affected ESPAltherma v2 users
  • Did all this with remarkable attention to French typography (correct −, –, ×) and consistency with the existing Dutch translation

If French support is useful to you, please thank him. His fork: github.com/azsono03/daikin_cycle_ml.


⚙️ Upgrade

No action required.

  • Home Assistant 2026.11+: auto-updates via Marketplace
  • Home Assistant 2026.10 or older: auto-updates via HACS as before

If you switch notification_language to fr, the UI will follow. No restart needed.

🔗 Links


☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs, consider supporting the project:


LWT Fine-Tuning card — 4-tab demo