v1.14.0 — COP for everyone, with or without a power meter
v1.14.0 — COP for everyone, with or without a power meter
Your heat pump's COP is now calculated even if you don't have a dedicated power meter. ESPAltherma 2.0 users get it automatically. ESPAltherma 1.x users get a built-in estimate. Power-meter users see no change.
📊 Featured dashboard — Daily Summary Tabbed
Overview |
Quality |
Cycles |
Events |
Tap any screenshot → opens the card's README with copy-paste YAML, requirements, and variables.
→ Card documentation & install guide
🌟 What's new in v1.14.0
The headline: COP now works without a power meter
The problem before this release. To show your heat pump's COP, the integration needed to know how much electricity the heat pump is using. Most users solve this by installing a smart power meter (like a Shelly or a P1 meter). But if you don't have one, your cop_today sensor was empty — no data at all.
Meanwhile, ESPAltherma 2.0 (the newer firmware by raomin) already calculates the electrical input internally and publishes it as a Stats: section. We just weren't reading it. That's fixed now.
What this means in practice:
- You have a power meter → nothing changes. Your meter remains the source of truth.
- You have ESPAltherma 2.0 (no power meter) → COP appears automatically. No configuration needed.
- You have ESPAltherma 1.x (no power meter) → COP appears using an estimate. You can fine-tune the estimate in settings.
- You have neither → no change. You still need one of the two to get COP data.
How the integration picks the right source
Three sources, checked in priority order. First available wins:
- Power meter (if you configured
sensor.warmtepomp_poweror similar) — most accurate, no adjustment applied. - ESPAltherma 2.0 Stats (auto-detected) — read directly from the device, no adjustment applied. ESPAltherma 2.0 handles phases and backup-heater internally, so we don't add anything on top (that would double-count).
- ESPAltherma 1.x fallback — calculated from inverter current × 230 V × number of phases + backup-heater consumption + a 100 W offset for pump, fan and electronics that the inverter current doesn't capture.
📖 Full explanation: COP without a power meter →
New settings page for fine-tuning
If you're on ESPAltherma 1.x, you can tell the integration about your installation so the fallback estimate is accurate.
Where to find it: Settings → Devices & Services → Daikin Cycle ML → Configure → COP calculation
| Setting | Default | When to change it |
|---|---|---|
| Supply phases | 1 | You have a three-phase electrical installation → set to 3 |
| BUH step 1 power (kW) | 3.0 | Your backup heater's step 1 has a different rating |
| BUH step 2 power (kW) | 3.0 | Your backup heater's step 2 is 6 kW (common on bigger units) |
You don't need to touch this if:
- You have a power meter configured → these settings are ignored.
- You have ESPAltherma 2.0 → these settings are ignored (v2 handles it internally).
You only need to touch this if: you're on ESPAltherma 1.x, you don't have a power meter, AND your defaults don't match your installation.
📖 Options reference: 4.10 COP calculation →
New sensor to see what's happening
sensor.daikin_cycle_ml_electrical_power_estimated shows the live electrical input estimate in watts. Its source attribute tells you exactly which path was used:
power_meter→ your power sensorespaltherma_v2_stats→ ESPAltherma 2.0 Stats sectioninverter_estimated_v1→ ESPAltherma 1.x fallback estimatenone→ no source available right now
Useful for verifying the cascade is working in real time, especially after changing installation settings.
⚠️ What you'll see after upgrading
Nothing is rewritten. Historical COP samples keep their old values. Only new samples (taken from the moment of upgrade) use the improved logic. No data loss, no recalculation, no migration step.
| Your setup | What changes after upgrade |
|---|---|
| Power meter configured | Nothing. COP values unchanged. |
| ESPAltherma 2.0, no power meter | COP now appears where it was empty. Numbers may differ slightly from a manual template — ESPAltherma Stats includes backup-heater consumption, most custom templates don't. |
| ESPAltherma 1.x, no power meter | COP now appears where it was empty. Starting defaults: single-phase, 3 kW + 3 kW backup heater. Adjust in COP calculation if your installation differs. |
| No power meter, no ESPAltherma Stats | Nothing. You still need one of them to get COP. |
🐛 Full fix list
New features — #206
- Internal electrical-input cascade — the priority logic described above (raomin Discussion #599 pattern)
- New OptionsFlow step — "COP calculation" for phases + BUH kW per step
- New sensor —
electrical_power_estimatedwith fullsourcetransparency - New internal fallback — COP is now calculated by the integration itself when no external COP sensor is configured
Defensive fixes — #206
These were surfaced by the full test suite while validating the cascade. They protect against edge cases:
_errors_totalclass-level default — 12 partial test fixtures were crashing in the error-handler when the coordinator was instantiated without running__init__first. Partial fixture setups only; no user impact._read_power/_read_power_w— now usegetattrguards, mirroring the new_power_from_meterpattern. Prevents AttributeError when the power sensor attribute isn't set.cycles_today()— skips cycles withstart_tsmore than 60 seconds in the future. Protects against clock skew and DB-import corruption._value_duty_cycle_today_pct— clamped to [0, 100]. Prevents the sensor from showing >100% at the midnight boundary.
Related issues
- #192 — Consume ESPAltherma 2.0 pre-computed entities. Partially handled by this release: the Stats section is now consumed. Full entity consumption remains blocked on external dependencies.
- #187 — ESPAltherma collaboration epic. Umbrella tracker for this release and future cross-project work with raomin.
Test coverage
- Test suite grew from 3703 to 3729 (+26 new tests)
- 4 new test files:
test_205_electrical_power_cascade.py— 14 tests for the cascade logictest_206_cop_fallback.py— 6 tests for internal COP fallbacktest_g1_defensive_guards.py— 6 tests for the defensive fixes abovetest_config_flow_cop_calc.py— 2 tests for the new settings page
- 100.00% branch coverage maintained across the whole codebase
- mypy strict clean across 38 source files
- ruff CI-parity clean
🙏 Credits
- raomin / ESPAltherma — the cascade design, Discussion #599 comment-19254135, plus continued reciprocal credit under CC BY 4.0.
- @MvdB1982 — the three-phase + BUH-inclusive installation report that confirmed this design works in the wild (source).
📚 Documentation
- README — COP without a power meter — the full end-user explanation
- Configuration — 4.10 COP calculation — the new settings reference
- Entities — 2.2 Live power — the new sensor reference
- Upgrade guide — v1.14.0 — what to do (and not do) after upgrading
- Full changelog — technical detail
- Discussions — questions and community help