Skip to content

1.23.0

Choose a tag to compare

@elRadix elRadix released this 18 Nov 16:20
· 24 commits to main since this release
d24187e
Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.23.0?

Dashboards that work in every language, more honest COP numbers, corrected Daikin datasheets, and first support for bivalent (heat pump + boiler) systems. No breaking changes.

  • Dashboards work in Dutch and French. Cards stayed empty when Home Assistant created your entities in Dutch or French (e.g. cyclus_status instead of cycle_state). Every card now finds its sensors in any language — even after you rename them. Reported in #347 and #369 — thank you @JoHuTi and @MBGek!
  • More realistic COP. Impossible readings from an external COP sensor (above 11 or infinite) are ignored, and short start-up dips below 1.0 no longer drag your averages down. COP today, weekly/monthly COP, SPF and heating-curve advice now only use trustworthy samples (#388).
  • Corrected Daikin datasheets. 24 models now use official Daikin figures (with source), including EPRA, ERGA, ERLA, EDLA, EBLA, EBLQ and the EVLQ hybrids. Hybrids no longer get a false "COP below datasheet" alert (#392).
  • Hybrid units recognised by their indoor code. EHYHBH / EHYHBX / CHYHBH / Rotex codes (e.g. EHYHBX08AAV3) map to the right EVLQ model.
  • Bivalent systems (heat pump + external boiler). Enable Bivalent Operation in ESPAltherma and the integration keeps boiler periods out of your heat-pump COP and stops false short-cycle alerts during boiler handovers (#288). Raised by @fransh47 in Discussion #176 — thank you!

✅ After updating

  1. Re-paste your dashboard cards. HACS updates the integration, not the cards you pasted. Copy the latest YAML from dashboard/cards/ into each card.
  2. Check your model (Settings → Devices & Services → Daikin Cycle ML → Reconfigure). If you picked one of these, switch to your real model — they do not exist in Daikin's range: EPRA04/06/11/14/16/18EAV3, ERLA04/06/08/12DAV3, EPGA10DAV3. Your data is kept.
  3. Bivalent or hybrid? In ESPAltherma uncomment Bivalent Operation, Boiler Operation Demand and Boiler DHW Demand — see Configuration §4.8.

🙏 Thank you

A big thank you to everyone who reported problems and shared diagnostics — this release exists because of you:

  • @JoHuTi — empty dashboards on a Dutch install (#347)
  • @MBGek — dashboards on a hybrid EVLQ08CV3, with diagnostics that also exposed the hybrid COP reference (#369)
  • @fransh47 — bivalent heat pump + gas boiler setup (Discussion #176 → #288)

Found something? Open an issue and attach your diagnostics.

📚 Docs: Troubleshooting — empty cards (§4.6) and COP guards (§5.1) · Model compatibility · Dashboard cards


🛠️ Technical Details & Fixes

Fixes:

  • #347 / #369 Dashboards empty on non-English installs - all 7 cards resolve entities via English id → entity-registry translation_key → NL/FR id; Jinja headers via integration_entities(). English output byte-identical. Pattern Analysis Dutch aliases fixed (cop_sww_*, cop_degradatie_week). PR #390.
  • #388 COP chain impossible values - cop_sensor_entity gated on finite and ≤ MAX_COP; classifier-flagged samples (is_transition_artifact=1) excluded from cop_today, hourly rollup, SPF, heating-curve advice and hybrid means; cop_normalized_a7w35 raw-attribute fallbacks. PRs #389, #391.
  • #369 Heating/DHW COP < 1.0 stored flagged via physics.below_cop_floor (Carnot classifier contract unchanged). PR #394.
  • #392 Datasheet audit - Daikin product-table values with ref + verified for 24 models; ERGA/EBLA second point relabelled A7/W55 → A7/W45; EVLQ A7/W35 nominal 5.04 / 4.45 (was 5.85 / 5.75); erga08evh7 datasheet; 11 non-catalogue models flagged verified: false (kept). PRs #393, #394.
  • #288 Bivalent support (phase 1) - boiler signals trusted when the source publishes Bivalent Operation; ERGA EVH aliases. PR #395.
  • ESPAltherma alignment - MODEL_ATTRIBUTES.json at beta b613d10; daily model-compat drift job fixed (missing label). PR #393.

Follow-ups: #397 remaining datasheet verification (EPGA, EDLQ, EBLQ011–016, EPSK, ERRQ) · #398 bivalent phase 2 (wizard, bivalent_active, boiler energy, alerts).

Tests: 6,649 tests, 100% coverage; new suites for dashboard entity resolution (Node-executed card JS, real HA template engine), datasheet audit, config-flow E2E for all 60 models, COP gate/floor and bivalent signals.

Changelog: CHANGELOG.md | Compare v1.22.10...v1.23.0



☕ Support