Daikin Cycle ML


GitHub stars

If this project helps you, a ⭐ star means a lot — it helps others discover it.


🌟 What's new in v1.30.0?

Heating-curve advice that never contradicts your room, hot water recognised on every EDLA, cards that stay where you scrolled, and you can now change the curve straight from the Efficiency card.

🔥 Advice and detection you can trust

Fixed What it means for your heat pump
🌡️ No more "raise the curve" in a warm room The advice said "raise the curve by 2 °C: the room stays below its setpoint" while the card also said "comfortable: room 22.5 ° for 22 °". The advice now knows your room setpoint. It only asks for a warmer curve when the room is really cold, and only for a cooler one when the room is not cold. A warmer curve when the room is already warm costs COP for nothing (#491).
🚿 Hot water recognised on EDLA (ESPAltherma v1) On these units "Operation Mode" stays "Heating" while the tank heats, so every hot-water run was counted as heating. The 3-way valve now marks hot water. Your hot-water runs, COP per mode and the hot-water band in the graphs are now correct (#487).
🎯 Your own ΔT target You set the Good dT threshold to 4 K (underfloor heating), but the Efficiency card kept judging against 5 K. The card now uses your setting (#492).
📄 More datasheet points for ERGA ERGA04/06/08 now have COP and capacity at A-7 and at 55 °C water (6 points instead of 2). COP against the datasheet and the Performance card now also work in frost and with hot water (discussion #493).
🔔 Alerts say what they mean An alert that says "no action needed" is no longer shown as a warning, and the alert text is no longer cut mid-word (#483).
📈 No false COP trend The 30-day COP trend is only shown when the weather explains it. A colder week no longer reads as "degradation". Today's runtime split also counts a run that is still open across midnight (#485).

📱 Cards

New / fixed What you get
📌 No more jumping to the top On phone and tablet the page jumped back to the top on every sensor update. The cards now update only what changed. Your scroll position, the open tab and a number you are typing stay put (#488).
🎛️ Change the curve from the card New option climate_entity: your Daikin leaving-water (or offset) climate entity. The Advice tab then shows − / + and Apply the advice (#491).
🛋️ Your own room sensor New option room_entity: a room sensor or room thermostat (which also gives the setpoint). The comfort check and the advice then follow your room. The card asks for both options when they are missing.
💬 Every heating-curve dot explained Tap any dot for a pop-up in the chart, next to the dot. The live dot's pop-up is open from the start and shows water, heat, COP and the distance to your curve. The last 48 h are drawn as rings (one per hour, newest darkest), and the legend shows every colour.
❄️ Negative values in the advanced chart Liquid refrigerant − leaving water below −3 K no longer falls off the chart. A negative difference is normal and is now described that way.
⚙️ Performance card The compressor dial starts at 0 rps (8 rps no longer reads 0 %), profile fields take decimals, and the add-point row shows examples and explains what to fill in.
🏅 IQS Platinum Translated error messages, icons for every entity and service, and three diagnostic entities off by default on new installs (#481).

🖼️ The native cards

Three cards served by the integration itself: no extra frontend cards, no YAML to paste. Add them from Add card and search for Daikin.

Daily summary Efficiency
Daily summary Daily summary dark Efficiency live Efficiency curve
Efficiency Performance
Efficiency advice Efficiency dark Performance Model profile

Daily summary · Efficiency · Performance · light and dark, English / Nederlands / Français

✅ After updating

  1. Update via HACS → Daikin Cycle ML → Update, then restart Home Assistant.
  2. Refresh your browser once (Ctrl+Shift+R; in the app, pull down) to load Efficiency card 1.3.0, Performance card 1.2.1 and Daily summary card 1.1.1.
  3. Optional: open the Efficiency card editor and pick your Daikin climate entity (climate_entity) and your room sensor or thermostat (room_entity).
  4. EDLA owners: hot-water runs are recognised from the next run on; earlier runs stay as they were recorded.
  5. No YAML cards to re-paste in this release.

🙏 Thank you

  • @BPLightlog: #487 and discussion #454 led to hot water being recognised from the 3-way valve on EDLA; #488 to cards that keep their scroll position; #492 to the card using your own ΔT target.
  • @HedzerHA: the Tweakers feedback in #491 led to advice that never contradicts the room, the climate and room options, the explained heating-curve dots and the Performance card fixes.
  • @JoHuTi: the Daikin brochure in discussion #493 gave the ERGA models four more datasheet points.
  • Everyone who shared a diagnostics file: they are replayed by the tests on every change.

📚 Manuals: Efficiency card · Performance card · Entities · Model compatibility

Found something? Open an issue (the form now asks exactly what we need) and attach your diagnostics.


🛠️ Technical Details

Heating-curve advice (#491): analyze_stooklijn now receives rt_setpoint (RT setpoint) and the room temperature from the controller, unless indoor_temp_sensor is set. A raise requires rt_setpoint − room > ROOM_OK_K (0.5 K), or room < comfort_min_c when there is no setpoint; otherwise the advice is keep with reason room_warm_enough. A lower step is blocked when the room is that cold (comfort_floor_reached).

Cycle detector (#487): without I/U operation mode, _split_mode treats valve ON + heating/unknown as dhw (60 s debounce, compressor running); dhw_active follows the detected run.

Cards: shared dcmPatch DOM patch (#488). hp_specs.target_dt_k comes from good_dt_threshold_k (2–15 K, else 5) (#492). Efficiency card adds climate_entity / room_entity, climate.set_temperature on apply, in-chart pop-ups and liquidRange (#491).

Also: IQS Platinum (#482), alert severity from the text level and a 1200-character clip at a word end (#484), open-run runtime split and TREND_MIN_R2 0.2 (#486), ERGA datasheet points (#493), bug-report version list synced by tools/sync_issue_template.py, feature request form, ingest tool area prefix fix, EDLA diagnostics in the corpus.

Tests: 7,602 tests, 100 % coverage. New: test_487_dhw_valve_only, test_488_card_patch, test_491_card_feedback, test_492_target_dt, test_493_erga_cop_points, test_issue_template. Each replays the reported case and fails on the old code.

Changelog: CHANGELOG.md | Compare v1.29.1...v1.30.0