Repository navigation
Architecture
src/peykan/
bus.py python-can helpers (make_bus, read_frames, shutdown_bus)
dbc.py DBC loading/decoding
obd.py OBD-II requests/responses, PID decoding, DTC encode/decode, reply matching
diagnostics.py the DBC's UDS-style protocol (service IDs, read/write classification)
j1939.py J1939: 29-bit IDs, PGN/SPN catalog, DM1, Request PGN, BAM transport
uds.py UDS over ISO-TP client helpers, DID/DTC/VIN decoding
logs.py log loading, analysis, signal series, replay, recording
safety.py transmit policy + audit log (TransmitGuard, GuardedBus)
parsing.py int/hex ID and payload parsing shared by tools and CLI
config.py PEYKAN_* settings + logging (to stderr)
models.py internal Frame dataclass
cli.py Typer CLI
data/ vehicle.dbc (sample DBC), sample_drive.asc (sample recording)
simulator/
state.py the driving + cabin model (DrivingState, tick(), CORRELATED_SIGNALS)
faults.py fault presets, FaultState, activation protocol
runner.py SimThread, OBD/DBC-diagnostic responders, run_simulator()
j1939_runner.py J1939 broadcasters, Request PGN responder, DM1 (with BAM)
uds_ecu.py engine ECU answering UDS and OBD Mode 09 over ISO-TP
profiles.py which DBC messages are sent and how often
server/
mcp_server.py MCP tools, routes, build_http_app(), main()
prompts.py server instructions + MCP prompts
schemas.py Pydantic result models
live_state.py background bus listener: frame history + signal snapshot
templates/dashboard.html
Protocol modules (obd, j1939, uds, logs, diagnostics) know nothing about MCP or the CLI; the server and CLI are thin layers over them.
The simulator, server and CLI share no Python state: they communicate only by sending and receiving CAN frames (the virtual bus by default, or a real adapter). Fault activation is a control frame; OBD, UDS and J1939 requests are real requests.
The consequence: python-can's virtual bus only exists inside one Python process. Anything that needs to see the simulator's traffic must run in the same process, which is why peykan demo (and the Docker image) run simulator and server together. See Troubleshooting.
A python-can Bus instance hands each received frame to one recv() call. Two threads reading the same instance silently split the traffic between them; this was a real shipped bug. Rule: every listener thread gets its own make_bus() instance (see run_simulator()); sharing an instance only for sending is fine.
simulator/state.py holds one DrivingState, advanced every 200 ms by a pure tick() function:
- Driving: throttle wanders, RPM and speed follow it with first-order lag, the engine warms toward 85 °C, fuel slowly drops, the battery charges to about 14.2 V while running.
- Cabin and environment: ambient light drifts (headlights follow it, and rain); rain comes and goes (wipers follow it and speed); cabin temperature settles to a 21.5 °C setpoint; doors auto-lock above 15 km/h; whether a passenger is aboard is chosen once per run.
CORRELATED_SIGNALS maps every DBC signal to a function of that state, and a test fails if a broadcast signal is left out. Unmodelled signals used to be random per frame, which made a car at 60 km/h report crashes and open doors.
From that state:
-
SimThread(one per DBC message,profiles.py) encodesENGINE_STATUS50 ms,ABS_STATUS100 ms,AIRBAG_STATUS200 ms,BODY_STATUS500 ms. Per signal: fault override first, then the state function. Values are clamped to what the signal's bit width can encode, because a declared DBC range isn't always reachable (ENGINE_TEMPdeclares 127.5 but 8 bits at scale 0.5 / offset -40 stop at 87.5). -
OBDResponderThreadanswers Mode 01/03/09 from the same state. -
UdsEcuThreadanswers UDS and the VIN over ISO-TP, with live DIDs from the state. - The J1939 threads broadcast PGNs from the same state.
Fault presets apply their state_effect to a copy of the state before any of these read it, so a fault is consistent across all protocols.
-
live_state.py::LiveState: one background listener per server process, keeping a time-windowed frame history (frames_since()) and the last value of every DBC and J1939 signal (snapshot()). Passive tools and the dashboard read from it, so they return immediately and never lose frames between calls. -
mcp_server.py::create_app()builds anMCPServer(mcp 2.x SDK) with the instructions and prompts fromprompts.py, registers the tools, the DBC resource and the HTTP routes, and creates oneTransmitGuard. -
build_http_app()returns the ASGI app for the SSE or streamable-HTTP transport with CORS and, on loopback, DNS-rebinding protection;main()serves it with uvicorn, or runs stdio. - MCP 2.x runs sync tools on worker threads, so blocking bus waits don't stall the event loop.
-
Passive (
read_can_frames,filter_frames,monitor_signal,get_vehicle_snapshot,read_j1939_dtcs): readLiveState, never open a bus. -
Request/response (OBD, UDS, J1939 request, DBC diagnostics, faults, replay): open a short-lived bus, wrap it with
guard.wrap(bus, purpose, write=...), send, wait for the matching reply, and shut the raw bus down infinally. Timeouts are capped byPEYKAN_MAX_DURATION_S.
safety.py::TransmitGuard decides per frame: is transmitting allowed on this interface, is this a write service, is the ID allowlisted. It records every attempt. GuardedBus is a real can.BusABC subclass (can-isotp refuses anything else), whose send goes through the guard, so frames sent by libraries (ISO-TP flow control) are covered too. See Real Hardware and Safety.
logs.py loads a file through python-can's LogReader (cached by path, size and mtime), sorts by time, and analyses it in one pass: per-ID timing, per-(signal, message) statistics, OBD Mode 03 codes and DM1 codes through a TransportReassembler. LogReplayer replays with original spacing; record_bus writes with can.Logger. See Recorded CAN Logs.
Getting started
Reference
Protocols
Features
Operating it
Contributing