Repository navigation
SAE J1939
J1939 is the CAN protocol of trucks, buses and off-highway machines. It uses 29-bit extended IDs whose bits are structured data: a 3-bit priority, an 18-bit Parameter Group Number (PGN) and an 8-bit source address (plus a destination address for peer-to-peer "PDU1" PGNs). Peykan implements it in j1939.py without a DBC; the simulator side is simulator/j1939_runner.py. It runs alongside the 11-bit signals on the same bus (turn it off with PEYKAN_J1939_ENABLED=false).
| PGN | Acronym | SPNs | Simulator period |
|---|---|---|---|
0xF004 |
EEC1 | 513 actual engine torque, 190 engine speed | 50 ms |
0xF003 |
EEC2 | 91 accelerator pedal, 92 engine load | 50 ms |
0xFEEE |
ET1 | 110 coolant temperature, 174 fuel temperature | 1 s |
0xFEF1 |
CCVS1 | 84 wheel-based vehicle speed | 100 ms |
0xFEF2 |
LFE1 | 183 fuel rate, 51 throttle valve position | 500 ms |
0xFEFC |
DD1 | 96 fuel level | 1 s |
0xFEF7 |
VEP1 | 168 battery potential | 1 s |
0xFECA |
DM1 | Active DTCs (SPN + FMI + occurrence count) and lamp status | 1 s |
0xEA00 |
Request | Asks ECUs to send a PGN | on demand |
0xEC00 / 0xEB00
|
TP.CM / TP.DT | Multi-packet transport | on demand |
Source addresses used by the simulator: engine 0x00, brakes 0x0B, instrument cluster 0x17. All values come from the same driving model as the 11-bit signals, so J1939 engine speed and DBC engine speed agree.
peykan j1939-decode 0x0CF00400 "00 00 00 20 4e 00 00 00"gives priority 3, PGN 0xF004 (EEC1) from source 0, ENGINE_SPEED 2500 rpm. J1939 signals also show up in get_vehicle_snapshot and the dashboard, grouped as J1939:<acronym>.
peykan j1939-request ET1 # or 0xFEEE, or 65262or the request_j1939_pgn tool, which accepts acronyms and hex strings as well as integers. When nothing answers, the reply lists the known PGNs so a model can correct itself.
peykan j1939-dtcsEach DM1 carries lamp states (malfunction indicator, red stop, amber warning, protect) and active DTCs. On a real truck every ECU broadcasts its own DM1, so read_j1939_dtcs / j1939-dtcs report the latest DM1 of every source address: all active codes, each tagged with source_address, plus each lamp at its most severe state and a per-ECU list.
A DM1 with two or more DTCs is longer than 8 bytes. J1939-21 sends such messages as a broadcast announcement (TP.CM, control byte 0x20 "BAM", with total size, packet count and the PGN) followed by numbered 7-byte data packets (TP.DT) 50 ms apart. Peykan builds these (j1939.build_bam) and reassembles them (j1939.TransportReassembler) everywhere DM1s are read: the tools, the CLI and log analysis. The misfire fault produces such a DM1 (SPN 1322 FMI 31 and SPN 651 FMI 7).
Only BAM (broadcast) is implemented; the peer-to-peer RTS/CTS variant isn't.
| Fault | J1939 DTCs |
|---|---|
overheat |
SPN 110 FMI 0 |
abs_fault |
SPN 84 FMI 5 |
low_fuel |
SPN 96 FMI 18 |
misfire |
SPN 1322 FMI 31, SPN 651 FMI 7 |
battery_low |
SPN 168 FMI 18 |
crash, door_ajar
|
none (airbag and body faults aren't reported over J1939) |
See Fault Injection.
Getting started
Reference
Protocols
Features
Operating it
Contributing